THE FIRST AND ON Li isuis-i NON-INVASIVE BLOOD PRESSURE M FOR MICE AND RATS IN THE WORLD. * fi mice (1.4 g) to aged rats (1 kg) ** W Colored mice such as C57BL/6 can be measured!
Open the catalog to page 1Introduction To measure blood pressure of small animals such as rats or mice using conventional BP Monitors, animals had to be preheated by some means. However, the advent of MK-2000 has made it possible to measure blood pressure without preheating animals provided that the room temperature is at least 23 degrees C. MK-2000ST is the successor to MK-2000 and has become more compact than ever before. MK-2000ST is ideal for investigating the effects of drugs on animals. Once the animals are restrained properly, just press the START key and HR (Heart Rate), SBP (Systolic BP), MBP (Mean BP) and...
Open the catalog to page 2Main Features 1. Two operation modes are available. With Mode 1 HR (Heart Rate) and SBP (Systolic Blood Pressure) are measured. With Mode 2 HR, SBP, MBP (Mean Blood Pressure) and DBP (Diastolic Blood Pressure, calculated value) can be measured. NOTE: HR (Heart Rate), SBP (Systolic BP), MBP (Mean BP), DBP (Diastolic BP, calculated value) 2. Continuous Measurement Function Continuous measurement can be performed up to ten (10) times. Further, continuous & rapid measurement can also be performed in order to shorten the measuring time. 3. Rapid Printout Function Onscreen data including average...
Open the catalog to page 3The Standard System Comes Supplied with:|
Open the catalog to page 4Animal Holders Mouse Holder (3S) Mouse Holder (SS) Mouse Holder (S) Mouse Holder (M) Mouse Holder (L) Rat Holder (3S) Rat Holder (SS) Rat Holder (S) Rat Holder (SM) Rat Holder (M) Rat Holder (ML) Rat Holder (L) Rat Holder (LL) Cuff-Pulse Sensorsl Cuff-Pulse sensor Cuff-Pulse sensor
Open the catalog to page 5iHiti Start.PrtScr,Print.Mode Animal No.: Weight : Animal Info: Pre-heating is not required. No damage to the animals. You can easily confirm the result of the measurement in the display Can be measured any small animal such as neonatal Rats and mice. The data can be transfered to PC and saved as CSV.
Open the catalog to page 6Correlation between simultaneously recorded blood pressures (BP) from carotid catheter and BP measured with the Model MK-2000 in mice. Good correlation was seen in a wide range of BP, which was induced by i.v. infusions of pressor or depressor agents. HEART RATE' S00 -400 -\m 4 o J BP am -I i... . -re:. i>o-10050-o BPin -m 150 100 50 f>
Open the catalog to page 7Design and production of genetically modified soybean protein with anti-hypertensive activity by incorporating potent analogue of ovokinin (2-7) (FEBS Letters 24860 (2001) 1-5 Syndecan-4 Deficiency Leads to High Mortality of Lipopolysaccharide-injected Mice (The Journal of Biological Chemistry, Vol. 276, No. 50, Issue of December 14, pp. 47483-47488, 2001) Validity and Application of Noninvasive Measurement of Blood Pressure in Hamsters (Exp.Anim. 52(4), 359-363, 2003) Progressive Development of Pulmonary Hypertension Leading to Right Ventricular Hypertrophy Assessed by Echocardiography in...
Open the catalog to page 8All Muromachi Kikai catalogs and technical brochures
-
MODEL MK-380M
2 Pages
-
SUPERMEX
6 Pages
-
nano tag
6 Pages
-
MODEL WAT-2006
3 Pages
-
MODEL MK-725/CU01
2 Pages
-
MODEL MK-725
4 Pages
-
CBX-303
4 Pages
-
MODEL TMW-4012C (10kW)
4 Pages
-
MODEL MMW-05 (5kW)
4 Pages
-
MODEL MK-380
2 Pages
-
MODEL MK-680AT/02
2 Pages
-
MODEL MK-680
2 Pages
-
MODEL MK-690S
3 Pages
-
MODEL MK-670
6 Pages
-
MODEL MK-610A
5 Pages
-
MODEL MK-630B
2 Pages
-
MODEL MK-810
2 Pages
-
MODEL MK-800
2 Pages
-
MODEL TK-252D
4 Pages
-
MODEL MK-1030
3 Pages
-
MODEL MK-101P
2 Pages
-
MODEL MK-101CMP
2 Pages
-
MODEL MK-V100
2 Pages
-
AneTrap4
1 Pages
-
MODEL MK-380Si
2 Pages
-
MODEL MK-12
3 Pages
-
MK-201D
2 Pages
-
MK-AT210D
3 Pages
-
MK-T110E
2 Pages
-
MK-A110D
3 Pages
-
SleepSign™
4 Pages