Overview: The document provides technical specifications and features of the RX DC eXTend X-ray unit by Cefla s.c., highlighting its wireless control, precision, and adaptability for medical imaging.
Specifications: The RX DC eXTend features a constant potential, microprocessor-controlled generator with a working frequency of 145 - 230 KHz. It has a focal spot of 0.4 mm and offers total filtration of 2 mm at various kV levels. The anode current is adjustable between 4 and 8 mA, and the voltage at the X-ray tube can be set to 60, 65, or 70 kV. Exposure times range from 0.020 to 1.000 seconds.
Features: The unit supports wireless control, allowing for fast installation and flexibility in positioning. It includes a button for ultra-fast shooting and settings for selecting X-ray acquisition programs. The RX DC CONNECT option enables PC connectivity for logging X-ray exposure data.
Imaging and Safety: The device ensures high-definition intraoral imaging with minimal X-ray dose, thanks to a high-frequency, constant potential generator. It offers automatic parameter modulation for optimal exposure and includes a rectangular collimator cone to reduce irradiated body surface area.
Installation and Versatility: The unit is designed for simple installation with solid arms available in lengths of 40 cm, 60 cm, and 90 cm. It can be wall-mounted or used on a portable cart, with a maximum arm extension of 230 cm from the wall.
Software and Connectivity: The RX DC eXTend is compatible with iRYS software for image management and supports various protocols like ICOM 3.0 and DICOM Node Connectivity. It requires a PC with Windows 10 or 11, an Intel Core i3 processor or higher, and a minimum of 4 GB RAM.
Conclusion: The RX DC eXTend offers a reliable and precise solution for dental imaging, with advanced features for ease of use and patient safety.
See more

Catalog excerpts

RX DC eXTend | MyRay-1

SEDE LEGALE ED AMMINISTRATIVA HEADQUARTERS Cefla s.c. Via Selice Provinciale, 23/a - 40026 Imola - BO (Italy) tel. +39 0542 653111 - fax +39 0542 653344 RX DC STABILIMENTO PLANT Via Bicocca, 14/c - 40026 Imola - BO (Italy) tel. +39 0542 653441 - fax +39 0542 653555 CEFLA NORTH AMERICA 6125 Harris Technology Blvd. Charlotte, NC 28269 - U.S.A. Toll Free: (+1) 800.416.3078 Fax: (+1) 704.631.4609 The images and technical specifications shown in this catalog are for indicative purposes only. As part of ongoing technological updates, technical specifications may be subject to changes without prior notice. In accordance with current regulations, in non-EU areas some products, as well as certain technical specifications, may have different availability and configurations. We encourage you to always contact your local distributor for up-to-date technical specifications, availability and configurations. MRXEGB251S00

 Open the catalog to page 1
RX DC eXTend | MyRay-2

TOTAL CONTROL Absolute positioning freedom and ultra-high definition intraoral imaging. RX DC - eXTend technology simplifies your work. Total, wireless control ensures fast installation and adaptation to all possible space requirements. MAXIMUM PRECISION Focal spot 0.4 mm and power 70 kV, 8 mA. RX DC CONNECT (optional) The RX DC X-ray unit can easily be connected to your PC via RX DC CONNECT. Via the USB port, you can log the X-ray exposure dose data in digital format. With iRYS you can add the image to the patient’s record and the relative X-ray log. Monitor the dose value over time, display...

 Open the catalog to page 2
RX DC eXTend | MyRay-3

PRECISION DIAGNOSIS Maximum image quality, minimum dose for the patient. RX DC - eXTend technology provides always-sharp images, a full configuration range and the exclusive flexibility of wireless technology. The DC generator in the head tube is high-frequency and constant-potential. This technology gives sharp images with greater detail and lower exposure times than would be attainable with AC X-ray units, which are characterised by variable emissions. Moreover, constant-potential design ensures image generation is unaffected by power fluctuations. RX DC - eXTend technology is reliable for...

 Open the catalog to page 3
RX DC eXTend | MyRay-4

TECHNICAL DATA (*) values depend on the country where the product is marketed.