Blood Collection Tube

Blood Collection Tube

Blood Collection Tube

Product catalog summary
Overview: This document provides detailed specifications and procedures for the collection of human venous blood using single-use containers manufactured by Nanchang Kindly Medical Technology Co., Ltd and Shanghai Kindly (KDL) Group. It outlines the types of tubes available, their additives, and the recommended procedures for specimen preparation and handling.
Specimen Collection and Tube Types:
  • Serum Tubes: Available in glass and PET materials, these tubes may contain clot activators and gel barriers to facilitate serum separation. Recommended coagulation time is 15-30 minutes, with centrifugation at 1500-2200g for 10 minutes at 18-25°C.
  • EDTA Tubes: Used for hematological studies, these tubes contain K2 or K3 EDTA as an anticoagulant. Proper mixing (8-10 inversions) is crucial to prevent micro-coagulation.
  • Heparin Tubes: Available with sodium or lithium heparin, these tubes are used for clinical chemistry analysis. Mixing immediately after collection is essential to avoid micro-clotting.
  • Coagulation Tubes: Contain sodium citrate for coagulation parameter examination. The mixing ratio is 1 part citrate to 9 parts blood.
  • Glucose Tubes: Contain sodium fluoride to inhibit glycolysis, ensuring stable glucose levels in samples.
  • ACD Tubes: Used for blood bank research and DNA testing, containing Acid Citrate Dextrose to preserve erythrocytes.
Procedures and Recommendations:
  • Specimens should be mixed immediately after collection to ensure proper distribution of additives and prevent clotting.
  • Centrifugation conditions vary by tube type but generally require 10 minutes at 18-25°C.
  • Temperature and storage conditions are critical for maintaining sample integrity, with specific recommendations for each tube type.
Key Specifications:
  • Tube materials include glass and PET, with various volume and size options available.
  • Cap colors are used to differentiate tube types and their specific applications.
  • Detailed specifications for each tube type, including additives and recommended handling procedures, are provided to ensure accurate and reliable test results.
See more

Catalog excerpts

Blood Collection Tube-1

HUMAN VENOUS BLOOD SPECIMEN COLLECTION SHANGHAI KINDLY(KDL) GROUP NANCHANG KINDLY MEDICAL TECHNOLOGY CO.,LTD

 Open the catalog to page 1
Blood Collection Tube-2

SHANGHAI KINDLY(KDL) GROUP NANCHANG KINDLY MEDICAL TECHNOLOGY CO.,LTD Specimen type and preparation method: Clinic Application Specimen Type Biochemical test, blood bank test Blood serum After blood collection, you don't need to invert and mix, let it stand for 1 hour and centrifuge Serum test Blood serum Recommended minimum time is 15-30 minutes 1500~2200g(RCF)for 10 minutes at18-25°C Blood plasma Immediately after blood collection invert and mix 8 -10 times, centrifuge Blood conventional check, full blood test Whole blood lmmediately after blood collection, invert and mix 8-10 times, mix sample...

 Open the catalog to page 2
Blood Collection Tube-3

SHANGHAI KINDLY(KDL) GROUP NANCHANG KINDLY MEDICAL TECHNOLOGY CO.,LTD KDL Serum Tubes KDL serum tubes could produce(no additive) high quality serum, it doesn’t contain clot activator with a gel barrier. Specification: No Additive. Cap Colour: Red & White. Ref. Clotting times: The recommended minimum coagulation time for serum tubes from patients who have not been treated with anticoagulant therapy is 60 minutes KDL Serum Tubes To obtain serum samples from plastic tubes, coagulation activator needs to be added in the tube, since the plastic surface alone is insufficient to activate the blood coagulation...

 Open the catalog to page 3
Blood Collection Tube-4

SHANGHAI KINDLY(KDL) GROUP NANCHANG KINDLY MEDICAL TECHNOLOGY CO.,LTD KDL Advance tubes with Gel & Clot Activator An inert gel is added in KDL advanced gel & clot activator tubes.The gel could separate the serum and the blood clot, which prevents the contamination of the serum from the separated cellular components during centrifugation. For example, the serum for certain analytes such as potassium,phosphorus and glucose must be separated from the cells within a few hours -otherwise the results will be distorted considerably. Using KDL Advance tubes in routine clinical chemistry, the analytes...

 Open the catalog to page 4
Blood Collection Tube-5

SHANGHAI KINDLY(KDL) GROUP NANCHANG KINDLY MEDICAL TECHNOLOGY CO.,LTD KDL Coagulation Tubes KDL coagulation tubes contain a buffered sodium citrate solution and are used for examination of coagulation parameters, The tubes are available with a citrate concentration of 3.2% The mixing ratio is 1 part citrate solution to 9 parts blood.Correct amount of blood collection is critical for correct coagulation analysis. Specification: 3.2% Sodium Citrate Coagulation conditions: •Platelet-rich plasma: 1500-2000g(RCF) for 5 minutes at 18-25°C •Platelet-poor plasma: Plastic tubes: 2000-2500g(RCF) for 10-15...

 Open the catalog to page 5
Blood Collection Tube-6

SHANGHAI KINDLY(KDL) GROUP NANCHANG KINDLY MEDICAL TECHNOLOGY CO.,LTD KDL ACD Tubes KDL ACD tubes are suitable for blood bank research,HLA typing, DNA paternity testing and other research.lt can effectively reduce the pre-analysis error of the specimen, improve the test accuracy,provide safety protection forpatients and medical staff,reduce nosocomial infection,The anti-coagulant ACD (Acid Citrate Dextrose) is used for the conservation of erythrocytes. ACD is available in two solutions, A and B, each with different mixture ratios. Studies have shown that the DNA preservation effect of ACD solution...

 Open the catalog to page 6

All Nanchang Kindly Meditech catalogs and technical brochures

  1. KDL-SABN

    4  Pages

  2. KDL-AUBIO

    2  Pages

  3. Biopsy needle

    3  Pages

  4. KDL-CN

    1  Page

  5. KDL-SPC

    1  Page

  6. KDL-SF

    1  Page

  7. KDL-SSI

    1  Page

  8. Special needle

    14  Pages

  9. Stopcocks

    1  Page

  10. Urinal Bags

    1  Page

  11. Blood Bags

    1  Page

  12. Rectal Tubes

    1  Page

  13. MEDICALTUBES

    1  Page

  14. SYRINGES

    1  Page

  15. Alive Tissue

    1  Page

  16. I.v Catheter

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.