Intracranial Balloon Dilatation Catheter

Intracranial Balloon Dilatation Catheter

Intracranial Balloon Dilatation Catheter

Product catalog summary
Overview: The document provides detailed specifications and performance evaluations of a medical catheter designed for interventional treatment of non-acute symptomatic atherosclerotic stenosis in intracranial arteries. It highlights the catheter's smooth operation, superior passage performance, and comprehensive clinical applications.
Specifications: The catheter is available in various models with lengths ranging from 1.0 mm to 5.0 mm and diameters from 6 mm to 30 mm. Each model is designed to cater to different clinical needs, ensuring broad applicability.
Performance Testing:
  • In vitro simulation testing: The catheter exhibits excellent passage performance, with a lower push force (0.80 N) compared to competitors (1.16 N), indicating superior push performance. The pullback force is also lower (0.29 N vs. 0.38 N), making it favorable for clinical applications.
  • In vivo animal testing: Demonstrates the catheter's ability to navigate smoothly through tortuous vascular regions, showcasing strong bending capability.
Indications: The catheter is intended for use in the interventional treatment of intracranial arteries, including the basilar artery, middle cerebral artery, and intracranial segments of the carotid and vertebral arteries. It utilizes balloon dilatation to enhance blood flow perfusion.
Design Features: The balloon is coated with an ultra-smooth hydrophilic coating, facilitating improved passage through the vasculature.
Contact Information:
  • Company: Nanjing YDB Medical Technology Co., Ltd.
  • Address: Room 115 of 1F, 2F, 3F, 4F in building 10, No.129, Fengshan Road, Gaochun Economic Development Zone, Nanjing City, Jiangsu 211316, China
  • Phone: 025-56865078
  • Fax: 025-56865079
  • Website: www.ydbmed.com
See more

Catalog excerpts

Intracranial Balloon Dilatation Catheter-1

Effortless and Seamless Flow Smooth and Controlled Operation Quick exchange mechanism for seamless performance Comprehensive specifications for broad clinical applications Smooth and continuous passage for optimal flow GUOXIEZHUZHUN20233031902 For Reference by Medical Professionals Only

 Open the catalog to page 1
Intracranial Balloon Dilatation Catheter-2

Advantages In vitro simulation testing: Excellent passage performance, slightly superior to competitors · Push force: 0.80 N (YDB) vs. 1.16 N (Competitor) · Pullback force: 0.29 N (YDB) vs. 0.38 N (Competitor) · Reachable vascular site: Middle cerebral artery (YDB) vs. Middle cerebral artery (Competitor) Test group Control group Test group Control group n vitro simulation testing: The push force of the test group is lower than that of the control group, demonstrating superior push performance. Both the test group and the control group exhibit low pullback forces, with the test group showing a...

 Open the catalog to page 2