Video System Specifications
Sensor resolution is 720 (H) x 720 (V) pixels, providing clear imaging capabilities.
Optical Data
The minimum working distance is 10 mm (0.4 inches), allowing for close-up inspections.
Preheater Specifications
The preheater power heats the camera's distal tip to approximately +5°C (9°F) above ambient temperature after 5 minutes of activation, ensuring optimal performance in cooler environments.
Electrical Data
The device uses a USB type A plug for LED power supply, camera operation, and pre-heating functions.
Mechanical Data
The cable length is 2950 mm (9.65 feet), and the total weight including the cable is 225 g (8 ounces), making it lightweight and easy to handle.
Storage Environment
The device can be stored in temperatures ranging from -20°C to +60°C (-4°F to +140°F).
Operating Environment
It operates effectively in temperatures between +10°C to +30°C (+50°F to +86°F), with air humidity levels of 30% to 75% (non-condensing), and air pressure from 600 hPa to 1060 hPa.
Essential Performance
The AURICAL OTOcam has no essential performance requirements.
Standards Compliance
Complies with EMC standards IEC 60601-1-2:2007, EN 60601-1-2:2007, IEC 60601-1-2:2014, and EN 60601-1-2:2015.
Safety
It is classified under Protection class II IEC 60601-1, IPX0, and Application class BF, ensuring safety in medical environments.
System Requirements
For detailed system requirements, refer to the OTOsuite data sheet.
Contact Information
GN Otometrics A/S, [email protected], www.otometrics.com
See more

Catalog excerpts

TECHNICAL SPECIFICATIONS OTOcam 300-1

AURICAL OTOcam Technical specificationsVideo system Sensor resolution 720 (H) x 720 (V) pixels Optical data Minimum working distance 10 mm (0.4 inches) Preheater Preheater power Heats camera distal tip to approx +5°C (9°F) above ambient temperature after 5 minutes of activation Electrical data USB plug USB, type A (LED power supply/Camera/Pre-heating) Mechanical data Cable length 2950mm (9.65 feet) Weight including cable 225 g (8 ounces) Storage environment Temperature -20°C to +60°C (-4°F to +140°F) Operating environment Temperature +10°C to +30°C (+50°F to +86°F) Essential performance AURICAL OTOcam has no essential performance. Sa fety Protection class II IEC 60601-1, IPX0 Application class BF System requirements For system requirements, please refer to the OTOsuite data sheet. u otometricsa division of natus

 Open the catalog to page 1

All Natus Hearing & Balance catalogs and technical brochures

  1. autoSCORE

    8  Pages

Archived catalogs

  1. autoSCORE

    6  Pages

  2. OAE is FUN

    8  Pages

  3. vHIT Flyer

    2  Pages

  4. AURICAL

    16  Pages

  5. Vestlab 100

    8  Pages

  6. Aquamatic II

    2  Pages

  7. ICS AirCal

    2  Pages

  8. AURICAL Aud

    4  Pages

  9. Madsen Zodiac

    16  Pages

  10. Otoscan®

    8  Pages

  11. Aurical HIT

    4  Pages

  12. Hi-Pro 2

    2  Pages

  13. ICS IMPULSE

    4  Pages

  14. MADSEN Astera²

    12  Pages

  15. Otobase®

    4  Pages

  16. Aurical®

    2  Pages

  17. OTOflex 100

    8  Pages

  18. Midimate 622

    2  Pages

  19. Micromate 304

    2  Pages

  20. Itera II

    8  Pages

  21. ICS NCI-480

    2  Pages

  22. MADSEN Xeta

    2  Pages

  23. Conera

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.