Technical specifications Frequency range Insert earphones: TDH39 earphones, HDA 200/HDA 300, ME-70, HOLMCO: BC: SF: Accuracy: FRESH noise stimulus: Narrow Band Noise masking: Frequency resolution: Standard frequencies: 125 - 8000 Hz Standard frequencies: 125 - 12500 Hz Standard frequencies: 250 - 8000 Hz Standard frequencies: 125 - 12500 Hz < 0.03%. Available in entire frequency range within the transducer specified range (for SF 125 - 12500 Hz). Accuracy 0.3% Available for each stimulus frequency. 125 to 12500 Hz at standard frequencies Stimulus types Tone audiometry Loudness Scaling Tone, Warble, Pulsed tone, Pulsed warble, FRESH Noise Warble, ISTS, FRESH Noise Narrow Band Noise (correlated) Speech Weighted Noise (correlated) White Noise (Wide band noise) (correlated) Stimulus modulation FM (Warble): SISI: Adjustable modulation rate and depth Modulation rate: 1-20 Hz (default: 5 Hz). Modulation depth: 1-25% of center frequency (default: 5%). 5, 2, 1 dB increments Signal presentation Accuracy of sound level Entire level range (AC): Entire level range (BC): Attenuator 1 or 5 dB step resolution over the entire range. HL Range The maximum output levels from AURICAL Aud depend on the actual sensitivity of the individual transducers, and they will be slightly different for each unit. However, the minimum requirements from IEC and ANSI standards are fulfilled for all units. Total harmonic distortion Air < 2.5% Bone < 5% TDH 39, ME-70, HOLMCO, HDA 200/HDA 300 headphones, and Insert Earphones Bone oscillator (Mastoid) Passive sound field speaker using the built-in amplifier, or External amplifier using the line output. Transducer options depend on how AURICAL Aud is ordered and calibrated. Outputs AC: BC: SF power output: SF line output: 2 x 2 mono jacks, 6.3 mm (1/4 inch) 1 x mono jack, 6.3 mm (1/4 inch) 3 x terminals, 3 x 40 W peak, 8 Ω load 2 x 1.6 Vrms, External inputs CD/Analog line in: Talk Back microphone: 0.2 to 2.0 Vrms, 10 kΩ, 1 stereo 3.5 mm (1/8 inch) jack Electret microphone Input voltage: 0.002 to 0.02 Vrms Input resistance: 2.21 kΩ. 3.5 mm (1/8 inch) jack with 3 powered USB ports DC power, 2.5 mm Stimulus presentation Normal, Continuous on, Pulsed Operator accessories Operator monitor headset - headphones: Operator microphone (desktop or boom): 40 mW 16 Ω 3.5 mm (1/8 inch) stereo jack Electret microphone Input voltage: 0.002 to 0.02 Vrms, Input resistance: 2.21 kΩ. 3.5 mm (1/8 inch) jack USB port connector Type: Speed: USB 2.0 device port High speed Transport and storage Temperature: Air humidity: Air pressure: Operating environment Mode of operation: Continuous Temperature: +15°C to +35°C (59°F to 95°F) Air humidity: 30% to 90%, non-condensing Air pressure: 700 hPa to 1060 hPa. (Operation in temperatures exceeding -20°C (-4°F) or +60°C (140°F) may cause permanent damage.)
Open the catalog to page 1
Technical specifications Disposal AURICAL Aud can be disposed of as normal electronic waste, according to WEEE and local regulations. Weight AURICAL Aud with HI-PRO 2: AURICAL Aud without HI-PRO 2: AURICAL Aud Power supply MeanWell MES50A-6P1J, 50W Power consumption Standards Audiometer: Patient Safety: EMC: IEC 60645-1, Type 2, 2010; IEC 60645-2, Type A, 1993;ANSI S3.6 IEC 60601-1, Class 1, Type B; UL 60601-1; CAN/CSA-C22.2 NO 601.1-90. IEC 60601-1-2:2007 and EN 60601-1-2:2007 IEC 60601-1-2:2014 and EN 60601-1-2:2015 HI-PRO 2 Built-in HI-PRO 2 (optional) Hearing instrument connection:...
Open the catalog to page 2All Natus Medical catalogs and technical brochures
-
Dantec® Clavis™ Handheld EMG
2 Pages
-
Natus® EEG32U™ EEG Amplifier
2 Pages
Archived catalogs
-
MiniMuffs®
2 Pages
-
CFM Olympic Brainz Monitor
4 Pages
-
NicoletOne vEEG System
2 Pages
-
ICS® Impulse
2 Pages
-
Madsen® Alpha OAE +
8 Pages
-
Madsen® Alpha OAE
8 Pages
-
THE AUDIOMETER
4 Pages
-
MDrive
2 Pages
-
NicoletOne
2 Pages
-
Madsen® Accuscreen
8 Pages
-
Aurical® Otocam 300
4 Pages
-
THE TEST CHAMBER
4 Pages
-
Otoscan®
8 Pages
-
Bio-logic® AuDX PRO FLEX®
4 Pages
-
MADSEN Capella²
4 Pages
-
Otometrics® Madsen A450
8 Pages
-
Aquamatic ll
2 Pages
-
ALGO 5
4 Pages
-
Olympic Circumstraint™
2 Pages
-
Embla ® S4500
2 Pages
-
NeuroCom®
4 Pages
-
BiliCare ™ System
4 Pages
-
neometrics
3 Pages
-
Echo-Screen® III
4 Pages
-
Smart Scale Model 50-51
2 Pages
-
Warm Scale Model 23-28
2 Pages
-
Smart Scale Model 60-65
2 Pages
-
Warmette
2 Pages
-
OraSwab
1 Pages
-
SugarPlum
2 Pages
-
SunFish
1 Pages
-
TootSweet
2 Pages
-
NeuroCom Smart EquiTest
4 Pages
-
Clinical Research System
4 Pages
-
NeuroCom inVision
4 Pages
-
NeuroCom Balance Family
12 Pages
-
VersaLab APM & APM2
4 Pages
-
VersaLab LE and SE
4 Pages
-
Peloton ™ Screening Services
2 Pages
-
audble
3 Pages
-
ALGO Supplies
2 Pages
-
Scout Sport
2 Pages
-
Bio-logic AuDX Pro
2 Pages
-
M.A.S.T.E.R II
3 Pages
-
ENoG
2 Pages
-
UltraPro S100
2 Pages
-
Xltek ® ICU Monitor
4 Pages
-
Bio-logic ® MASTER ® II
2 Pages
-
Bio-logic ® Navigator ® Pro
3 Pages
-
StethoDopTM
2 Pages
-
Pocket-Dop II
2 Pages
-
Pocket-Dop 3?
2 Pages
-
ImexDop CT+?
2 Pages
-
Nicolet? Elite
4 Pages
-
FreeDop?
2 Pages
-
Mini-Pasteurmatic
2 Pages
-
Pasteurmatic 3000/3500
3 Pages
-
neoBLUE radiometer
2 Pages
-
OLYMPIC BILI-METER
2 Pages
-
Biliband Datasheet
1 Pages
-
neoBLUE Family Brochure
2 Pages
-
AUDX
6 Pages
-
Echo-Screen Brochure
2 Pages
-
ABaer
3 Pages
-
ALGO 3i
2 Pages