Product catalog summary
Overview: The Aurora® system is a customizable electromagnetic tracking solution designed for OEM image-guided applications. It enables precise localization and visualization of medical instruments within 3D space during procedures, without requiring a line of sight.
Key Components:
  • System Control Unit (SCU): Manages the field generator, collects data from sensor interface units, and calculates sensor positions and orientations. Available in enclosed and PCB formats for integration into OEM systems.
  • Field Generator (FG): Emits a low-intensity electromagnetic field to establish the measurement volume. Five different FGs are available, each with unique measurement volumes and mounting options.
  • Sensor Interface Unit (SIU): Amplifies and digitizes sensor signals. Supports up to two SIUs per SCU, with multiple port options for connecting sensors.
  • Sensors: Embedded in medical instruments to provide localization data. Supports up to 16 6DOF or 32 5DOF sensors.
Specifications:
  • SCU Dimensions: 84 x 172 x 230 mm; Weight: 2.0 kg
  • FG Dimensions (Planar 20-20): 200 x 200 x 71 mm; Weight: 2.6 kg
  • SIU Dimensions: 53 x 172 x 114 mm; Weight: 660 g
Applications: Suitable for integration into various medical fields such as interventional radiology, electrophysiology, endoscopy, and ENT surgery. The system ensures accurate navigation of medical instruments to treatment sites.
Limitations and Responsibilities: The Aurora system is a general-purpose metrology instrument and is not approved for medical use. OEM customers or end users must determine its suitability and are responsible for testing, certification, and validation before use in medical applications.
See more

Catalog excerpts

Aurora®-1

Navigate new possibilities in OEM image-guided applications with our premier, highly customizable ® electromagnetic tracking solution that supports today’s most intricate interventional approaches: Aurora The Aurora solution tracks micro sensors that can be embedded into OEM medical instruments. When integrated into the workflow of OEM image-guided surgery systems, the Aurora acts as the link between patient image sets and 3D space, allowing instruments to be instantly localized and visualized within the host interface – even during in-vivo procedures. No line of sight is needed. *Simulated example of OEM applicat

 Open the catalog to page 1
Aurora®-2

The Aurora solution consists of four interconnected components to track the real-time positions and orientations of embedded sensors. Components are available in different sizes and formats—and highly customizable—for seamless integration into OEM image-guided surgery systems and workflows in interventional radiology, electrophysiology, endoscopy, ENT surgery, and more . Exceptional tracking performance ensures OEM * medical instruments are navigated to the treatment site exactly as planned, every time. System Control Unit (SCU) Sensor Interface Unit (SIU) Amplifies and digitizes the signals...