1. Catalogs
  2. Neobiotech
  3. SINUS LATERAL APPROACH KIT
video corpo

SINUS LATERAL APPROACH KIT

SINUS LATERAL APPROACH KIT

SINUS LATERAL APPROACH KIT

Product catalog summary
Overview: The Sinus Lateral Approach Kit is designed for performing a lateral window sinus lift with minimal invasiveness. It features a smaller flap and window size compared to conventional techniques, providing a complete set of tools for the procedure.
Specifications:
  • Minimal flap size and smaller window size.
  • Instruments designed for opening the lateral wall near the crest.
  • Reamers compatible with conventional surgical motor handpieces at 2,000rpm.
  • Tapered trunk of LS reamer controls drilling depth up to 3.5mm without drill stops.
Procedure:
  1. Flap: Open the soft tissue.
  2. LS-Reamer: Create a lateral hole, maintaining a steady drilling motion at 2,000rpm. Both sides of the LS-reamer blade should contact the bone. Optionally, use a C-Reamer to save a bone core disk.
  3. Bone Graft: Place bone graft material and cover the hole with a collagen membrane. Suture the soft tissue.
  4. Bone Disk: The LS reamer leaves a thin bone disk.
  5. Detach Sinus Membrane: Use #1 elevator for mesial-distal detachment.
  6. Elevate Sinus Membrane: Use #2 elevator for inferior detachment and #3 for anterior and posterior areas.
Recommendations:
  • Use copious irrigation during drilling.
  • This guide is for educational purposes; refer to the instructions for additional product information.
Ordering Information: Catalog Number SLAKIT - Sinus Lateral Approach Instrument Kit.
Manufacturer: Neobiotech Co., Ltd, Seoul, Korea. Contact: Tel 82-2-582-2885, Fax 82-2-582-2883, www.neobiotech.com
See more

Catalog excerpts

SINUS LATERAL APPROACH KIT-1

SINUS LATERAL APPROACH KIT MINIMALLY INVASIVE • Minimal flap size • Smaller window size than conventional techniques • Instruments provide method of opening the lateral wall near the crest SPEED • Reamers designed to be used with conventional surgical motor handpiece at 2,000rpm • Tapered trunk of LS reamer designed to control drilling depth up to 3.5mm without use of drill stops COMPLETE • Kit provides a complete set of tools for performing a lateral window sinus lift

 Open the catalog to page 1
SINUS LATERAL APPROACH KIT-2

Sinus Lateral Approach Kit Technique Guide Bone Disk •• Open the soft tissue. •• The LS reamer will leave a thin bone disk. Detach sinus membrane Bone graft •• Make a lateral hole with the LSreamer. •• #1 elevator is used to initiate detachment of the membrane in the mesial-distal area. •• Place bone graft material. •• Keep the drill upright and maintain a steady drilling motion; Both sides of the LS-reamer blade should be in contact with the bone while drilling. •• Cover the lateral hole with a collagen membrane. •• Suture the soft tissue. •• Continue drilling. •• Speed: 2,000rpm •• NOTE: C-Reamer...

 Open the catalog to page 2

All Neobiotech catalogs and technical brochures

  1. R-Brush

    1  Page

  2. T-Brush

    2  Pages

  3. EZ-GBR Kit

    2  Pages

  4. ACM

    1  Page

  5. CTi-mem

    1  Page

  6. IT-III active

    2  Pages

  7. EZ-Fixing

    11  Pages

  8. IT-III Active

    20  Pages

  9. IS-III Active

    2  Pages

Archived catalogs

  1. IS-II active

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.