Overview
The Delta 3300 is a compact and lightweight Defibrillator and Transcutaneous Pacemaker Analyzer designed for precision testing of defibrillators and external pacemakers. It integrates the functionalities of a defibrillator tester, pacemaker analyzer, and 12-lead ECG/arrhythmia simulator.

Product Highlights
  • Tests all defibrillators, including AEDs, with monophasic and biphasic waveform measurement.
  • Features include energy and cardioversion measurement, peak voltage and current reading, waveform storage, and playback.
  • Pacemaker testing capabilities include load resistance from 50 to 1100 Ohms, amplitude, rate, pulse width, demand sensitivity, refractory period, immunity, and pulse energy.
  • 12-lead ECG and arrhythmia simulation with performance waveforms.
  • Li-Ion rechargeable battery for portability.

Features
  • Large LCD display with backlight for easy reading.
  • Test results can be saved and uploaded to a PC using Netech ProCom-Print software.
  • Comes with a hard carrying case and a 2-year warranty.

Specifications
  • Energy output measurement up to 800 J with various resolution levels and accuracy.
  • Load resistance of 50 ohms ±1% with a sampling time of 20 μS.
  • Waveform storage and playback capabilities with ECG outputs and paddles.
  • Sync time measurements with a timing window starting at 40 ms at each R wave peak.
  • Test load range from 50 to 1100 Ohms with specified accuracy levels.
  • Pulse measurements include amplitude, rate, and pulse width with high accuracy.
  • Demand sensitivity test with various waveform options and pacer rates.
  • ECG output with user-selectable amplitude and high accuracy.
  • Immunity test with interference signal and ECG signal amplitude specifications.
  • Refractory period measurement with high accuracy.
  • General ECG configurations with lead simulation and output impedance details.
  • Arrhythmia selections include various ventricular and atrial conditions.
  • Performance waveforms with specified rates and amplitudes.

General Information
  • Operating temperature range from +15°C to +35°C and storage from 0°C to +50°C.
  • LCD display with LED backlight for clear visibility.
  • Data input/output via RS-232C for computer control.
  • Power supplied by a 7.4 Volt Li-Ion battery with a 100-230 VAC input charger.
  • Durable housing made of high-impact ABS plastic.
  • Dimensions: 10.25 x 6.25 x 2.5 inches; Weight: 3.3 lbs.

Accessories
  • Standard accessories include defibrillator paddle adapter, Li-Ion battery charger, interface cables, carrying case, user manual, and ProCom Print software.
  • Optional accessories available for specific brands and additional connectivity.

Contact Information
Netech Corporation, 110 Toledo St., Farmingdale, New York 11735. Phone: 1-800-547-6557. Email: [email protected]. Website: www.NetechCorp.US
See more

Catalog excerpts

Delta 3300-1

Defibrillator / Transcutaneous Pacemaker Analyzer Best Value OVERVIEW The Delta 3300 Defibrillator / Transcutaneous Pacemaker Analyzer is a precision instrument for testing defibrillators and external (Transcutaneous) Pacemakers. It combines the complete testing functions of a Defibrillator Tester, Transcutaneous Pacemaker Analyzer and 12-Lead ECG / Arrhythmia Simulator into one compact, lightweight, and easy to-use instrument. The Delta 3300 tests all Defibrillators including AEDs. It measures both monophasic and bi-phasic waveforms. It is compact, light weight and easy to use. The test results can be saved in the internal memory and uploaded to the PC and printed using ProCom Print software (CD included with the unit). PRODUCT HIGHLIGHTS • Energy and cardio version measurement • Large LCD Display with Backlight • Peak voltage and current reading • Waveform storage and Play back. • Compact & Light weight (3lbs) • Tests all Automated defibrillators • Test results can be saved & upload to PC • Pacemaker loads from 50 to 1100 Ohms using Netech ProCom-Print software • Pacer Amplitude, Rate, Pulse width • Li-Ion Rechargeable Battery • Demand Sensitivity, Refractory period, • Hard Carrying case immunity and pulse Energy • 12 Lead ECG, Arrhythmia, Performance • Incredible Value • Li-Ion Rechargeable Battery Netech Corporation 1 Toledo St., Farmingdale, New York 1 10 1735 | Phone: 1-800-547-6557 | Email: in

 Open the catalog to page 1
Delta 3300-2

Defibrillator / Transcutaneous Pacemaker Analyzer DEFIBRILLATOR ANALYZER Energy Output Measurement: Maximum Energy: 800 J Display Resolution: Based on Auto Range Auto Range: 2 - 9.99 J, 10-99.9 J, 100-800 J Resolution: 0.01 J ( 2 -9.99), 0.1 J (10-99.9), 1 J (100-500) Accuracy: ±1 % of reading ± 0.1 J (2-9.9), ± 1J (10-99), ± 2 % (100-500) ± 1J TRANSCUTANEOUS PACEMAKER ANALYZER Test Load Range: 50 -1100 Ohms in steps of 100 Ohms. Accuracy: 50 - 500 ohm ±1 % 500 - 1100 ohm ±1.5 % Pulse Measurements: Load Resistance: 50 ohms ±1 %; non-inductive (< 1 μH) Sampling Time: 20 uS Measurement Time Window:...

 Open the catalog to page 2

All Netech catalogs and technical brochures

  1. Minisim 1000

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.