Overview: The document provides a comprehensive overview of the GraphNet ts ventilator, designed for pediatric through adult applications, with a software upgrade for neonatal ventilation. It integrates both invasive and non-invasive ventilation modes and features automatic leak compensation, a comprehensive respiratory mechanics package, and a 72-hour trend monitoring capability.
Key Features:
  • Display and Interface: The ventilator includes a 12-inch LED screen for displaying vital signs and an intuitive user interface with a touch screen, backlighted knob, rapid access keys, and high visibility alarm indicators.
  • Monitoring Capabilities: It monitors vital signs such as minute ventilation, frequency, exhalation time constant, and leaks, with a built-in respiratory mechanics menu for informed decision-making.
  • Transport and Non-Invasive Ventilation: The ventilator supports intra-hospital transport without interrupting ventilation and offers non-invasive ventilation with automatic leak compensation.
  • Alternative Air Supply: In the absence of central air supply, a medical-grade air compressor can be used as an alternative.
Technical Specifications:
  • Intended Use: Suitable for invasive and non-invasive ventilation for adults, pediatrics, and optionally neonates-infants.
  • Operative Modes: Includes various modes such as VCV, PCV, PSV, CPAP, SIMV, MMV, APRV, and NIV for different patient categories.
  • Parameter Selection: Offers a wide range of settings for tidal volume, minute volume, inspiratory time, respiratory rate, FiO2, and more.
  • Alarms: Features light and audible alarms for various conditions, with a record of events that is printable and non-deletable.
Additional Features:
  • Connectivity: RS-232C with DB-9 connector for data transfer.
  • Electrical and Pneumatic Requirements: Operates on 100-240 V with automatic voltage switching and requires specific gas supply pressures.
  • Accessories: Includes reusable patient circuit, expiratory sets, nebulizer kit, and optional accessories like a heater-humidifier and neonatal test lung.
Compliance and Approvals: The ventilator is FDA and CE approved, ensuring compliance with international standards.
See more

Catalog excerpts

Neumovent GraphNet ts-1

Ventilation therapy without compromise.

 Open the catalog to page 1
Neumovent GraphNet ts-2

PEDIATRIC THROUGH ADULT APPLICATIONS SOFTWARE UPGRADE FOR NEONATAL VENTILATION INTEGRATED INVASIVE AND NON-INVASIVE VENTILATION AUTOMATIC LEAK COMPENSATION COMPREHENSIVE RESPIRATORY MECHANICS PACKAGE PACKAG 72 HOURS OF TRENDS INTUITIVE USER INTERFACE INTERNAL BATTERY CAPACITY > 2 HOURS LOW COST OF OWNERSHIP TWO-YEAR WARRANTY FDA AND CE APPROVED

 Open the catalog to page 2
Neumovent GraphNet ts-3

Compact design GraphNet ts ventilator provides clear and complete display of vital signs variables on a built-in 12-inch LED screen. User-friendly and intuitive programming to help manage critical patients safely through: • Touch screen. • Backlighted knob to conrm parameters. • Rapid access keys. • High visibility alarm indicator visible from far away provides early warnings of critical conditions. Comprehensive monitoring Monitoring of vital signs variables such as mandatory and spontaneous minute ventilation, spontaneous frequency, exhalation time constant, leaks. Built-in respiratory mechanics...

 Open the catalog to page 3
Neumovent GraphNet ts-4

Ventilation therapy without compromise. Non-invasive ventilation A ventilation mode with automatic leak compensation. Provides effective patient ventilation, while keeping the upper respiratory airways intact. Ability to deactivate tidal volume and minute volume alarms in order to avoid bothering the patient. Reliable volume and leak monitoring through an interface that improves synchronization and patient comfort. Intra-hospital transport mode Provides for patient transfers inside medical facility without interrupting ventilation and monitoring. Alternative air supply In the case of absence...

 Open the catalog to page 4
Neumovent GraphNet ts-5

Technical Data and Specifications INTENDED USE Ventilator designed to provide Invasive and Non-invasive ventilation for the critical care management of adult, pediatric and optionally neonate-infant (including premature) patients. OPERATIVE MODES ADULTS AND PEDIATRICS • VCV – Volume Control (Assisted/Controlled). • PCV – Pressure Control (Assisted/Controlled). • PSV – Pressure Support. • CPAP – Continuous Positive Airway Pressure. • SIMV (VCV) + PSV. • SIMV (PCV) + PSV. • MMV + PSV – Mandatory Minute Ventilation. • PSV + Tidal Volume Assured. • APRV – Airway Pressure Release Ventilation. • NIV...

 Open the catalog to page 5
Neumovent GraphNet ts-6

Calle Pública s/n - Av. La Voz del Interior 5400 - X5008HJY - Córdoba – Argentina Phone: (54 351) 4144600 - Fax: (54 351) 4144605 [email protected] www.neumovent.com

 Open the catalog to page 6