DC STIMULATOR

DC STIMULATOR

DC STIMULATOR

Product catalog summary
Overview: The DC-STIMULATOR is a programmable direct current stimulator designed for clinical use in transcranial direct current stimulation (tDCS). It is used to modulate brain activity, particularly for reducing depressive symptoms, and can be used alone or alongside other treatments.
Specifications:
  • Adjustable current up to 2,000 µA in 250 µA increments.
  • Application time adjustable up to 30 minutes.
  • Direct current fault tolerance of max. 1% and fluctuation of max. 0.02%.
  • Internal 16-bit D/A conversion with a time resolution of less than 1 ms.
  • Power supplied by built-in rechargeable batteries, with approximately 6 hours of stimulation time at 1 mA.
  • Device dimensions: 13.5 cm x 22.5 cm x 5.5 cm, weight: 0.8 kg.
Features:
  • Microprocessor-controlled constant current source.
  • Single channel for anodal and cathodal stimulation.
  • High safety standards with multistage monitoring and automatic termination of stimulation.
  • Study mode for double-blind active and sham stimulation.
  • Optional external trigger input.
Advantages:
  • Ensures patient safety with continuous monitoring of electrode impedance.
  • Intuitive menu navigation with a display and four buttons.
  • Ability to save individual stimulation parameters.
Applications: Primarily used for tDCS to reduce depressive symptoms, especially in patients who do not respond to SSRI medications. However, no additional benefits beyond placebo effects are expected for these patients.
Contact Information: neurocare group AG, Munich, Germany. Email: [email protected], Phone: +49-89-356 4767 0.
See more

Catalog excerpts

DC STIMULATOR-1

The DC-STIMULATOR is a clinical stimulator designed to be used in clinics and medical practices. Using this device, doctors and psychologists can carry out transcranial direct current stimulation (tDCS) using weak currents up to 2 mA over 15 to 30 minutes. tDCS represents part of interventional neurophysiology; the electrical charges and densities administered during tDCS are below the threshold for releasing a stimulus and take modular effect to existing neuronal elements. Depending on duration, current intensity, current density and frequency used, the transcranial Electrical Stimulation influences cortical activity. The DC-STIMULATOR is used for tDCS for reduction of depressive symptoms. It can be applied as monotherapy or in combination with other treatments. For patients with selective serotonin reuptake inhibitor (SSRI) medication and failure to another drug, no further benefit of tDCS beyond unspecific (placebo) effects can be expected. • highest patient safety standards due to multistage monitoring of the current path, automatic termination of the stimulation as well as continuous monitoring of the electrode impedance • intuitive menu navigation via display and four buttons • individual setting and saving of the stimulation parameters • optional: study mode for double-blind active and sham stimulation

 Open the catalog to page 1
DC STIMULATOR-2

fade duration total stimulation time = fade in + duration + fade out tDCS: total stimulation time = fade in + duration + fade out DC-STIMULATOR Specifications • adjustable current up to 2,000 µA in increments of 250 µA • adjustable application time up to 30 min • max. 1 % relative direct current fault tolerance • max. 0.02 % direct current fluctuation • internal 16 bit D/A conversion • internal time resolution < 1 ms (sample rate 2,048 sps) • “tDCS“ stimulation mode: duration 1,800 s, increment 30 s, duration of fade in / fade out 1-120 s, increment 1 s • power supply from built-in rechargeable...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.