NE-8000
3Pages

{{requestButtons}}

Catalog excerpts

NE-8000 - 1

New Era Pump Systems Inc. www.SyringePump.com NE-8000 Syringe Pump Model NE-8000 High Pressure Syringe Pump Features - All Programming features of the NE-1000 syringe pump. - Syringes size up to 140 mL. 200 mL partially filled (About 160 mL). - Pumping force over 200 lbs. Adjustable force limit: Force adjustment knob reduces the maximum force to reduce damage to syringes. Limit Switches - Two adjustable limit switches: One sets the infusion limit, one sets the withdrawal limit. To adjust the limit switches, loosen the white thumbscrew, then slide the collar to the required position. Then re-tighten the thumbscrew. - When the pusher block reaches a limit switch, the pump will either: 1) Trigger a Program Event function 2) Continue with the next Program Phase 3) Stop the pump. If a Program Event is set (Event Function), the Event trap will be triggered and the Pumping Program will continue execution with the Program Phase set in the Event Function. Otherwise, the Pumping Program will start the next Program Phase unless the next Program Phase pumps in the same direction. This is a safety feature to prevent attempting to pump past the limit switch. The pump will instead stop. Limit switches can be used as a program volume target. Limit switches will override the volume target setting. Additional Notes - Does not have stall detection. - Pusher block has a solid nut block. It is not releasable. - To position the pusher block, use the purge function: Set the pumping direction with the direction key ‘ and the pusher block will move at then press and hold the ‘Start/Stop’ key. The display will indicate top speed in the set direction. Release the ‘Start/Stop’ key to stop the pump. Maintenance − Periodic lubrication is required for proper operation. Failure of the nut block can occur if not properly lubricated. − Lead-screw: Grease − Guide Rods: Oil − Remove accumulation of dirt or debris WARNING Use extreme caution. The NE-8000 can deliver enough force to break syringes or any objects that get caught in the mechanism. Broken syringes and associated plumbing can create dangerous projectiles that can cause bodily harm. Keep fingers and loose clothing away from mechanism.

Open the catalog to page 1
NE-8000 - 2

New Era Pump Systems Inc. www.SyringePump.com NE-8000 Syringe Pump Syringe Syringe Inside Maximum Minimum Manufacturer (mL) Diameter Rate Rate (µL/hr) (all names ™) (mm) (mL/hr) B-D 1 4.699 312.4 1.733 Poulten &Graf (Glass) Steel Syringes Hamilton Microliter (Glass) Maximum Minimum Rate Rate (µL/hr) (µL/hr) Maximum Rate (mL/min) Inside Maximum Minimum Diameter Rate Rate (mm) (mL/hr) (µL/hr)

Open the catalog to page 2
NE-8000 - 3

Specifications Mechanical & Electrical Model NE-8000 Style Stand-Alone Maximum Syringe Size 140 mL; 200 mL partially filled Drive block type: Solid (Must use Purge function to move pusher block). Motor type: Motor steps per revolution: Motor to drive screw ratio: Drive screw pitch: Step motor 200 14/22 20 revolutions/” Power supply type: Power supply output rating: Power connector: Voltage at power connector: Amperage: External, country and power source specific 24V DC @ 1200 mA 2.1 mm, center positive, DC 24V DC at full load 1200 mA at full load Operational Maximum force: Micro-stepping:...

Open the catalog to page 3

All New Era Pump Systems catalogs and technical brochures

  1. NE-500

    7 Pages

  2. NE-1002X

    3 Pages

  3. NE-300

    3 Pages

  4. NE-4000

    3 Pages

  5. 9000B

    3 Pages

  6. NE - 1000

    3 Pages

  7. FW-1-X2

    1 Pages

  8. NE-9000

    3 Pages