ALIANS DISTAL RADIUS
8Pages

{{requestButtons}}

Catalog excerpts

ALIANS DISTAL RADIUS - 1

NNOVATION MEANS MOTION ALIANS DISTAL RADIUS POLYAXIAL LOCKING SYSTEM DUALTEC SYSTEM®II • Precontoured implant

Open the catalog to page ١
ALIANS DISTAL RADIUS - 2

T ECHNI C A L FE AT U R E S anatomical plate with optImized fixation SLOTS EPIPHYSEAL FIXATION ø2.8 locking screws Hole for insertion of a K-wire to locate the joint space. Distal slots : 2 monoaxial locking slots in the middle of the plate 2 polyaxial locking slots (+/- 10°) on each side of the plate (1 on the radial styloid side, 1 on the ulnar side) The window in the plate allows for better visualization of the fracture reduction. Proximal slots : 2 monoaxial locking slots Holes for fastening fast guide onto the plate. DIAPHYSEAL FIXATION ø2.8 screws K-wire holes fixation. 1 oblong slot...

Open the catalog to page ٢
ALIANS DISTAL RADIUS - 3

A NGULAR R ANGE : +/-10 ° P OLYA XI A L LO CKING R A NGE Greater angulation is possible: +/-10° locking range polyaxial locking plate system DTS2® TECHNOLOGY Polyaxial locking nut and clip Polyaxial locking screw AVERAGE PRE-DETERMINED ANGULATIONS OF PLATE SLOTS* In the epiphyseal area, slots have pre-determined angulations (see diagrams below). Thanks to the DTS2® polyaxial locking system, distal slots for styloid process and on the ulnar side allow an additional angulation of +/- 10°. Ulnar 9.3° Distal 20° Ulnar 2.5° Distal 33.4° * Angulation based on the slots’ axes in the diaphyseal...

Open the catalog to page ٣
ALIANS DISTAL RADIUS - 4

S U R GI C A L T ECHNI Q U E SIMPLE reduction The joint space is assessed using a 1.4mm K-wire (K-Wire-D1.4-L120). Reduction of the fracture. Temporary fixation with K-wire. The fast guide is locked onto the plate with the screwdriver (ANC082). Simple fracture If necessary, the position of the plate can be adjusted thanks to the oblong slot before the cortical screw is tightened (see a). The plate can be provisionally stabilized with K-wires (see b). Drill (ANC088) using the guide gauge (ANC450) and insert a cortical screw (CT2.8Lxx) into the oblong slot. The depth can be directly read on...

Open the catalog to page ٤
ALIANS DISTAL RADIUS - 5

R EDU CTION OF THE FRACTURE USING THE PLATE Complex fracture Lock the guide gauge (ANC268R) onto the plate, drill (ANC088), then insert the distal screw (SDT2.8Lxx). Repeat for all distal slots. (See Polyaxial surgical technique). The fracture is reduced using the plate until both anterior cortical lines are in place. Insert and tighten the cortical screw (CT2.8Lxx) into the oblong slot. Complete the fixation by inserting all the locking screws in the remaining slots (SDT2.8Lxx). P OLYA XIAL surgical technique INSTRUMENTS for monoaxial and/or polyaxial techniques in epiphyseal area Fast...

Open the catalog to page ٥
ALIANS DISTAL RADIUS - 6

alians d istal ra d ius range RIGHT PLATES - GREEN ANODIZED LEFT PLATES - BLUE ANODIZED

Open the catalog to page ٦
ALIANS DISTAL RADIUS - 7

im plants R EFE R EN CE S Alians radius plates Polyaxial plate for distal radius - Narrow head - Size 1 - Right Polyaxial plate for distal radius- Narrow head - Size 1 - Left Polyaxial plate for distal radius - Narrow head - Size 2 - Right Polyaxial plate for distal radius - Narrow head - Size 2 - Left Polyaxial plate for distal radius - Standard head - Size 1 - Right Polyaxial plate for distal radius- Standard head - Size 1 - Left Polyaxial plate for distal radius - Standard head - Size 2 - Right Polyaxial plate for distal radius - Standard head - Size 2 - Left Polyaxial plate for distal...

Open the catalog to page ٧
ALIANS DISTAL RADIUS - 8

Ø2.0mm quick coupling drill bit – L125mm Length gauge for Ø2.8mm screw 2.0mm hexagonal non prehensor screwdriver Ø2.0mm guide gauge for locking screws Ø4.5mm AO quick coupling handle - Size 1 Reduction tool Guide gauge for Ø2.8mm cortical screws Fast guide for DTGVPS2 and DTGVPS3 plates Fast guide for DTDVPS2 and DTDVPS3 plates Fast guide for DTGVPW1 plate Fast guide for DTDVPW1 plate Fast guide for DTGVPN2 plate Fast guide for DTDVPN2 plate Bone Reduction Forceps Bone Reduction Forceps, curved, pointed Length gauge ø2.0mm guide gauge for locking screws IMPLANTS TRAY INSTRUMENTS TRAY The...

Open the catalog to page ٨

All Newclip Technics catalogs and technical brochures

  1. INITIAL C™

    12 Pages

  2. PERIACTIV

    3 Pages

  3. Single Use kit

    12 Pages

  4. NATIV

    2 Pages

  5. ATLANTIC OW

    6 Pages

  6. ATLANTIC CW

    6 Pages

  7. FLATFOOT

    2 Pages

  8. Activ Ankle

    8 Pages

  9. ALIANS ULNA

    8 Pages

  10. FOREFOOT

    8 Pages

  11. ACTIVMOTION

    8 Pages

  12. INITIAL R

    8 Pages

  13. KEMIS

    4 Pages

  14. ALIANS ELBOW

    8 Pages