FLATFOOT - 1

©indication : The Footmotion Plating System is intended for arthrodeses, fractures and newclip-technics osteotomies fixation and revision surgeries of the foot in adults. Contraindications : • Serious vascular deterioration, bone devitalization, • Pregnancy. • Acute or chronic local or systemic infections. • Lack of musculo-cutaneous cover, severe vascular deficiency affecting the concerned area. • Insufficient bone quality preventing a good fixation of the implants into the bone, • Muscular deficit, neurological deficiency or behavioral disorders, which could submit the implant to abnormal mechanical strains. • Allergy to one of the materials used or sensitivity to foreign bodies. • Serious problems of non-compliance, mental or neurological disorders, failure to follow post-operative care recommendations. • Unstable physical and/or mental condition. TECHNICAL FEATURES > Calcaneal displacement osteotomy plate i a _i fatslxx (Example of application: Medial displacement calcaneal osteotomy)) • A central window allowing: - a better visualization of the osteotomy site, - a good vascularization for an optimized fusion. • A non locking central screw allowing the calcaneal shift without a specific instrumentation. • 2 transfixation screws allowing: - the stability of the construct, - the compression between the two bones fragments, - the optimization of the anchorage with converging screws FVTSLxx > Evans osteotomy plate (Example of application: Lateral column lengthening) • Precontoured plates: design respecting: - the calcaneal anatomy, - the calcaneo-cuboid joint, • Converging screws: a stable fixation of the system, • 2 types of plates: - plate with wedge for osteotomy, - plate without wedge for graft addition. Precontoured plates: respecting the 1st cuneiform anatomy, • Converging screws: allowing a stable fixation of the system, • 2 types of plates: - plate with wedge for osteotomy, - plate without wedge for graft addition REFERENCES 02.8 MM SCREWS Ref. Description SLT2 8Lxx Locking screw - 02.8 mm - L xx mm ' L10 mm to L40 mm (2 mm incrementation) RLT2 8Lxx Non locking screw - 02.8 mm - L xx mm ' L10 mm to L40 mm (2 mm incrementation) SLT3 5Lxx Locking screw - 03.5 mm - Lxx mm ' L10 mm to L40 mm (2 mm incrementation) r 3 5. Non locking screw - 03.5 mm - Lxx mm . ^ L10 mm to L40 mm (2 mm incrementation) The instrumentation and the screws are available in the Footmotion Plating System set INNOVATION MEAN

Open the catalog to page 1
FLATFOOT - 2

S U R GI C A L T ECHNI Q U E Non-contractual pictures. Example: Medial displacement calcaneal osteotomy 2. Position the plate and stabilize it temporarily by inserting three Ø1.2 mm pins (33.0212.070) into the dedicated holes : - 2 in the osteotomy site, - 1 in the posterior part of the calcaneus. 3.Lock the threaded guide gauge (ANC577) in one of the posterior holes. Drill (ANC591), then directly measure the drilling depth on the threaded guide gauge. Insert a Ø3.5 mm (SLT3.5Lxx) locking screw with the T8 screwdriver (ANC575). 4. Insert the second locking screw to complete the posterior...

Open the catalog to page 2

All Newclip Technics catalogs and technical brochures

  1. PERIACTIV

    3 Pages

  2. Single Use kit

    12 Pages

  3. NATIV

    2 Pages

  4. ATLANTIC OW

    6 Pages

  5. ATLANTIC CW

    6 Pages

  6. Activ Ankle

    8 Pages

  7. ALIANS ULNA

    8 Pages

  8. FOREFOOT

    8 Pages

  9. ACTIVMOTION

    8 Pages

  10. INITIAL R

    8 Pages

  11. KEMIS

    4 Pages

  12. ALIANS ELBOW

    8 Pages