The PERIACTIV system is designed for osteosynthesis of femoral periprosthetic fractures in adults. It features an anatomical plate that aligns with the femur's natural shape, as defined by Pr Lefèvre. The plate is constructed from titanium alloy, enhancing fatigue resistance and ensuring long-term stability under mechanical stress.

Polyaxial Locking Fixation System (DTS)
  • Allows screw orientation before locking.
  • Utilizes self-tapping screws with a reinforced core diameter.

Conservative Treatment Approach
The Newclip plate is anatomically contoured and available with convergent or divergent adjustable screws, promoting a conservative treatment method.

Plate Variants
  • Symmetrical plates available in two sizes.
  • Asymmetrical plates available in three sizes.

Indications and Contraindications
The implants are intended for adult femoral periprosthetic fractures. Contraindications include serious vascular deterioration, infections, insufficient bone quality, and allergies to materials used.

Product Specifications
  • DTS Self-Tapping Screws: Available in various lengths from 15 mm to 75 mm, with options for sterile versions.
  • Diaphyseal Plates: Available in sizes 1 and 3, with lengths of 238 mm and 314 mm respectively.
  • Distal Plates: Available for both right and left sides, in sizes 1 to 3, with lengths ranging from 163 mm to 315 mm.

Instruments
  • Includes hexagonal screwdrivers, reamers, length gauges, drill bits, and templates for plates.

Additional Information
Surgeons should rely on their clinical judgment when using these products. Availability may vary by market, and it is advised to consult with a NEWCLIP TECHNICS representative for specific product availability.
See more

Catalog excerpts

PERIACTIV-1

P E R I A CT I V Indications : The implants of the PERIACTIV are intended for osteosynthesis of femoral periprosthetic fractures in adults. Contra-indications : • Serious vascular deterioration, bone devitalization. • Pregnancy. • Acute or chronic local or systemic infections. • Lack of musculo-cutaneous cover, severe vascular deficiency affecting the concerned area. • Insufficient bone Altération osseuse ne permettant pas une tenue correcte des vis dans l’os. • Muscalar deficit, neurological deficiency or behavioral disorders, which could submit th implant to abnormal mechanical strains. • Allergy to one of the materials used or sensitivity to foreign bodies. • erious problems of non-compliance, mental or neurological disorders, failure to follow post-operative care recommendations. S • Unstable physical and/or mental condition. DIAPHYSEAL PLATE Symmetrical plate, TECHNICAL FEATURES An anatomical plate The plate design follows the anatomic features of the femur, delineated notably by Pr Lefèvre (Brest). O ptimized fatigue resistance The plate is made of titanium alloy and its specific design optimizes fatigue resistance. P olyaxial locking fixation system (DTS) - Possible orientation of the screw before locking - Self-tapping screws - Reinforced core diameter A conservative treatment The Newclip plate is anatomically contourned and is supplied with either convergent or divergent adjustable screws. O ptimized fatigue resistance The plate is made of titanium alloy and its specific design optimizes fatigue resistance. A stable plating system The dimensions of the plate are designed for long term resistance to the mechanical stresses the femur is subjected to. DISTAL SUPRA CONDYLAR PLATE Asymmetrical,

 Open the catalog to page 1
PERIACTIV-2

IMPLANTS REFERENCES DIAPHYSEAL PLATES Periprosthetic midshaft femoral plate - size 1 - L 238 mm DTS® self-tapping screw Ø4.5 mm - L 15 mm Periprosthetic midshaft femoral plate - size 3 - L 314 mm DTS® self-tapping screw Ø4.5 mm - L 18 mm DTS® self-tapping screw Ø4.5 mm - L 21 mm DTS® self-tapping screw Ø4.5 mm - L 24 mm DTS® self-tapping screw Ø4.5 mm - L 27 mm DTS® self-tapping screw Ø4.5 mm - L 30 mm DTS® self-tapping screw Ø4.5 mm - L 35 mm DTS® self-tapping screw Ø4.5 mm - L 40 mm DTS® self-tapping screw Ø4.5 mm - L 45 mm DTS® self-tapping screw Ø4.5 mm - L 50 mm DTS® self-tapping screw Ø4.5...

 Open the catalog to page 2
PERIACTIV-3

INSTRUMENTS REFERENCES INSTRUMENTS 3.0 mm hexagonal screwdriver with US quick coupling system Ø4.2 mm reamer with US quick coupling system Length gauge for Ø4.5 mm screws Quick coupling drill bit Ø4.0 mm Ø4 mm DTS® Trauma drill guide Quick coupling 3.0 mm hexagonal screwdriver Ø6.0 mm US quick coupling handle QTSMx template of plate QTxEx template of plate The information presented in this brochure is intended to demonstrate a NEWCLIP TECHNICS product. Always refer to the package insert, product label and/or user instructions before using any NEWCLIP TECHNICS product. Surgeons must always rely...