CATALOGUE 2020/21
42Pages

{{requestButtons}}

Catalog excerpts

CATALOGUE 2020/21 - 1

Call Center: +390236102100 – E-Mail: info@nhcelettromedicali.com PHYSIOTHERAPY- REHAB - MEDICINE SHOCK WAVES HP NHC 1118 LITO THERAPY ESWT TOP LINE PNEUMATIC BALLISTICS - 2 COMPRESSORS 5 BAR - 20 MODULABLE FREQUENCIES PRE-SET AND FREE PROTOCOLS 3 FOCAL TRANSMITTERS - MULTIFOCAL AND RADIAL SHOCK WAVES - PAINLESS THERAPIES MOST POWERFUL EQUIPMENT OF EUROPE CERTIFIED BY THE ITALIAN MINISTRY OF HEALTH THEY ARE EMPLOYED IN DIFFERENT THERAPEUTIC BRANCHES ORTHOPEDICS - TRAUMATOLOGY - SPRTS MEDICINE REHALIBITATION MADE IN ITALY The main pathologies treated with SHOCK WAVES HP NHC 1118 LITO THERAPY ESWT TOP LINE Epicondylitis Epithrocleitis Insertional Tendinipathies - Impingement Patellar and Goose Foot Tendinopathies - Pubalgia - Trochanteric Bursitis - Metatarsal Head Bursitis Achilles tendinopathies, Calcaneal apophysis - Bandelletta Syndrome - Spine and Calcaneal Spur - Plantar Fasciitis Dupuytren (Hand) - Induratio Penis Plastica - Sudeck’s Syndrome - Etc… PLEASE NOTE ITALIAN VAT VALUE IS 22% WHICH WILL NOT BE APPLIED TO COMPANIES BUT ONLY TO PRIVATE CUST

Open the catalog to page 1
CATALOGUE 2020/21 - 2

ELECTROMEDICAL DEVICES Preset and free protocols 8 Touch screen Also automatic bipolar and monopolar The safety and effectiveness of the Technology find feedback in numerous international research works, New methodologies in the treatment of pathology muscular and traumatic of the athlete, • Osteo Warm Med technology in the treatment of acute and chronic sports pathologies, rehabilitation in Tendinopathies, The use of Osteo technology Warm Med in sprained ankle injuries, Thanks to reactions induced within the biological tissue, the Osteo Warm technology Med is able to support and enhance...

Open the catalog to page 2
CATALOGUE 2020/21 - 3

ELECTROMEDICAL DEVICES LASER NHC BI LUX 810/980 nm 12W NHC BI LUX 810/980 nm 12W THE STRENGTH AND EVOLUTION OF LIGHT New power laser, with double wavelength 810 nm and 980 nm 12W directly on the skin, without dispersions. The two wavelengths allow to obtain an excellent anti-inflammatory biostimulation effect and high penetration into tissues. The Laser Bipower Lux NHC allows to immediately improve the symptoms of inflammatory pathologies and with its high level of absorption in liquids, produces a high pain relief analgesic effect. Essential in the orthopaedic, neurological, dermatological...

Open the catalog to page 3
CATALOGUE 2020/21 - 4

ELECTROMEDICAL DEVICES TK1 PROFESSIONAL PORTABLE TECAR THERAPY Tecar therapy today represents the physical means most used in Europe Separate capacitive and resistive modes Touch display and joystick in case of dirty hands of cream Voice support Physical characteristics: • Very small dimensions (36 x 26 x 5 cm, weight 5.2 kg) more or less like a book • 12/10 steel case, shock resistant and for complete wave shielding electromagnetic • Absolutely silent, with 7 fans controlled by a microprocessor • 7 electrodes of different sizes • 3 resistive electrodes with quick coupling made of steel • 4...

Open the catalog to page 4
CATALOGUE 2020/21 - 5

PLEASE NOTE ITALIAN VAT VALUE IS 22% WHICH WILL NOT BE APPLIED TO COMPANIES BUT ONLY TO PRIVATE CUSTOMERS ELECTROMEDICAL DEVICES • Class A amplifier; to generate the purest form of sine wave • Maximum available power 600w, Power Maximum effective 150 watts • Two ways of setting commands: • Touch Screen with display of all parameters • Joystick, very useful especially with hands dirty with cream • (unique on the market Italian) • Two waveforms • Sinusoidal • Quadra • Two operating frequencies: • 485 KHz • 1 MHz • Two modes: • Standard • Athermic (true athermic, emission 250 ms, 750 ms zero...

Open the catalog to page 5
CATALOGUE 2020/21 - 6

ELECTROMEDICAL DEVICES TECAR FISIO NHC CAPACITIVE AND RESISTIVE 300W Capacitive and Resistive 300 Watt The Endogenous Heat that regenerates Frequency 300 - 500 KHZ Indicated for a series of Classes of Diseases: Neuropathies; Tendinopathies; Joint pathologies; Joint rehabilitations; Rheumatic form; Distortive Traumatologies; Muscle pathologies; You hesitate from Rehabilitation Surgery; Syndromes of Sports Origin; Acute and Chronic Pain; Cicatricial outcomes. Equipment: 6 Capacitive and Resistive electrodes 1 Plate complete with cable 1 Power cable 2 Handpiece holder 1 Electrode holder 24...

Open the catalog to page 6
CATALOGUE 2020/21 - 7

Deeply focused thermotherapy from 1 cm to 8 cm a a high and controlled temperature. Hyperthermia is indicated: - Tendon pathologies: Peritendinitis, Tendinopathies Insertional and Tendinosis; - Muscle pathologies: Bruises, strains and tears - Neural and Osteo-Cartilage Pathologies: Bruises, Sprains, Osteoarthritis; - Bursitis - Fasciitis Microstrip technology on Teflon Max power 200 W Hyperthermia possibility to focus on an area of the body, at a variable depth (from 1 cm up to 8 cm), enough energy to bring the affected part to one well specified and controlled high temperature....

Open the catalog to page 7
CATALOGUE 2020/21 - 8

ELECTROMEDICAL DEVICES LTS-60 SCANNING LASER HP POWER LTS-60 SCANNING LASER is an electromedical appliance used in scan laser therapy. The LTS-60 is designed to use the Laser to a precise length wave (1064 nM) for the purpose therapeutic. Laser allows the LTS-60 to to be characterized by an emission of 6 Watts continuous, reach a remarkable precision in the areas from treat, excellent even in children environments, thanks to a guiding light perfectly collimated with the beam Laser. The LTS-60 is a device, meant to achieve a ideal depth for treatments therapeutic. Also, always thanks to the...

Open the catalog to page 8
CATALOGUE 2020/21 - 9

DESK 12W realizes photochemical biostimulations in depth, metabolic stimulation, analgesia, antiedemigens, antiphlogistic, treats in absolute continuous or pulsed safety, the states superficial musculoskeletal inflammatory diseases. 10“ Touch Screen Display Uptodate software Therapeutic Protocols for Anatomic Areas e Specialized Branches. Fast, Safe and Guaranteed Results! PLEASE NOTE ITALIAN VAT VALUE IS 22% WHICH WILL NOT BE APPLIED TO COMPANIES BUT ONLY TO PRIVATE CUSTOMERS ELECTROMEDICAL DEVICES

Open the catalog to page 9
CATALOGUE 2020/21 - 10

ELECTROMEDICAL DEVICES SHOCK WAVE HP NHC 1118 13.900€ + S.C. LITO THERAPY ESWT TOP LINE 5BAR MADE IN ITALY Shock waves HP NHC 1118-LITO THERAPY ESWT TOP LINE 5 BAR AND 1/20 FREQUENCIES MODULABLE WITH FOCAL TRANSMIT-TERS, MULTIFOCAL AND RADIAL Shock waves with the Applicator amortized - Painless therapies - Most powerful equipment in Europe. Dupuytren’s disease can affect one or both hands and can co-ver any finger, thumb including DUPUI-TREM CALCIFICATION OF THE HAND CURTAIN. Dupuytren’s disease is a pathology borne by the hand characterized by progressive and permanent bending of one or...

Open the catalog to page 10

All NHC Medical & Beauty catalogs and technical brochures