Introduction
Nikon has launched two high-resolution 16.25-megapixel CMOS cameras for microscopy: the DS-Ri2 color digital camera and the DS-Qi2 monochrome digital camera. These cameras are designed to offer high pixel density, a large field of view, and fast data transfer via USB3.0, ensuring fast frame rates and high-resolution images.
Specifications
The DS-Ri2 is noted for its accurate color rendition, ideal for recreating color images as perceived by the human eye. The DS-Qi2 is characterized by high sensitivity and low noise, making it suitable for capturing fluorescent images with a high signal-to-noise ratio. Both cameras support high-resolution imaging up to 4908 x 3264 pixels.
Image Processing and Sensitivity
Nikon's advanced algorithms ensure natural color reproduction. The cameras support ISO sensitivity settings from ISO200 to ISO12800, enabling vivid fluorescent color image capture. The DS-Qi2's high quantum efficiency and low read noise facilitate the detection of faint fluorescent signals.
Performance
The DS-Ri2 can display full-pixel images at 6 fps and averaged images at 45 fps, aiding in easy focusing. The DS-Qi2 supports high-speed live imaging and captures images at up to 45 fps, with excellent linearity for reliable quantitative analysis.
Camera System and Control
Nikon provides a flexible camera system with three camera head models and two controller models, allowing customizable setups for various applications. The DS-L3 stand-alone control unit features a touch panel monitor for intuitive operation, while the DS-U3 PC-use control unit supports advanced image processing and analysis.
Integration and Software
The cameras integrate with Nikon's NIS-Elements software for comprehensive imaging control, including measurement, analysis, and management of acquired images. The software offers various packages to suit different applications, from basic imaging to advanced research.
Conclusion
Nikon's new digital cameras for microscopes provide high-resolution imaging capabilities, advanced color reproduction, and flexible system integration, making them suitable for a wide range of biological and industrial applications.
Specifications and Features
Nikon's imaging systems support multidimensional imaging, integrating with systemized microscopes to handle up to 4 dimensions for Br and 6 dimensions for Ar. The systems are compatible with Windows® 7 Pro 32/64bit and come with a range of image processing and analysis functions.
Imaging Software
NIS-Elements software allows for the acquisition of full bit depth multi-color images, combining multiple fluorescence wavelengths and different illumination methods. It supports motorized focus control for 3D image reconstruction and offers multi-dimensional image display capabilities.
Image Processing Capabilities
The software includes features like HDR image acquisition, Extended Depth of Focus (EDF), and image stitching for creating wide field of view images. Manual and auto measurement tools are available for length, area, and object counting, adhering to standards like JIS G0551 and ASTM E112-96.
Camera Specifications
The document details various camera models, including their image sensors, recordable pixels, ISO sensitivity, and live display modes. It also covers exposure control, white balance, and image adjustments.
Connectivity and Power
The systems support USB and Ethernet connections, with options for external sync input/output. Power supply requirements and consumption details are provided.
Operating Environment
The equipment operates within a temperature range of 0-40°C and a maximum humidity of 60% RH without condensation.
Contact Information
The document lists contact details for Nikon's various international offices, including phone numbers, fax numbers, and email addresses for sales inquiries.
See more

Catalog excerpts

Digital Sight Series Brochure-1

Digital Cameras for Microscopes

 Open the catalog to page 1
Digital Sight Series Brochure-2

Introducing two new high resolution 16.25-megapixel CMOS cameras to Nikon’s lineup of cameras for microscopy Two Nikon FX-format CMOS sensor cameras join the Digital Sight series of microscope digital cameras: the DS-Ri2 color digital camera and the DS-Qi2 monochrome digital camera. High pixel density and large eld of view coupled with USB3.0 high speed data transfer offer fast frame rates and high resolution images with these new CMOS sensors. Large Format CMOS Sensors Nikon manufactures CMOS sensors and imaging technologies for professional DSLR cameras, and now has optimized our sensors for...

 Open the catalog to page 2
Digital Sight Series Brochure-3

High pixel density, high sensitivity and low noise are key features of the DS-Qi2 monochrome camera. Pig kidney epithelial cells expressing GFP-EB3 tubulin Sample courtesy of: Michael Davidson, National High Magnetic Field Laboratory, Florida State University 16.25 megapixel (not interpolated) and accurate color rendition are features that make the DS-Ri2 an excellent choice for recreating color images as they eyes see them. Malleablecastiron (Objective: TU Plan Fluor 20x) The tissues of the liver, HE staining (Objective: CFI Plan Apochromat λ 10x) Photos courtesy of: Kazuhiro Muraoka, Photography...

 Open the catalog to page 3
Digital Sight Series Brochure-4

Fast, one-shot capture of ultra-high Microscope Camera 16.25 megapixel Color High-resolution Mouse cerebellum sagittal section, HE staining (Objective: CFI Plan Apochromat λ 4x) High-resolution images 16.25-megapixel CMOS sensors for astonishing image quality The DS series enables one-shot instantaneous capture and fast storage of images with resolution as high as 4908 x 3264 pixels, without pixel shifting or pixel stepping. This pixel density is ideally suited for photomicrography of ultra-ne structures or patterns in biological or industrial samples, at low or high magnications. Photography...

 Open the catalog to page 4
Digital Sight Series Brochure-5

resolution colon images. Conventional camera (Objective: TU Plan Fluor 20x) Resolution chart (Objective: TU Plan Fluor 20x) High-speed live display High-speed display, even of supra-HDTV-class live images The DS-Ri2 can display 4908x3264 pixel (full-pixel) images at 6 fps, or 1636x1088 pixel (3x3 pixel averaging) images at 45 fps. This fastlive frame rate makes fine focusing easy to perform. with theLVIOOND industrial microscope (Objective: TU Plan Fluor 5x) 1636x1088 pixel / Exposure time: 10Ousec High sensitivity, low noise Fluorescent color image capture with high signal to-noise ratio Sensitivity...

 Open the catalog to page 5
Digital Sight Series Brochure-6

Capture Low light uorescence and Lar g Monochrome Microscope Camera 16.25 megapixel Monochrome Cooled Indian Muntjac Deer Skin Fibroblast Cells, Cytoskeletal F-actin labeled with Alexa Fluor 488 Sample courtesy of: Michael Davidson and Florida State University High sensitivity Excellent linearity Detects even faint uorescent signals Reliable quantitative analysis made possible 7.3µm pixels, high quantum efciency, and very low read noise With a linearity error of ±1%, the DS-Qi2 is a superb tool for allow the DS-Qi2 to read in even faint uorescent signals. measuring intensities in uorescence samples,...

 Open the catalog to page 6
Digital Sight Series Brochure-7

Time-lapse images (every 1 second) of LLC-PK1 cells with GFP-EB3 tubulin. Each image represents the maximum intensity projection of the timelapse, allowing visualization of the end-binding protein located on the microtubule plus-ends, and allowing tracing of the microtubule path. DS-Qi2 captures an extremely large eld of view, but still represents very ne details as demonstrated in this cropped timelapse sequence from a large FOV image. Objective: CFI Plan Apochromat λ 60x oil / NA: 1.4) Sample courtesy of: Michael Davidson, National High Magnetic Field Laboratory, Florida State University Time-lapse...

 Open the catalog to page 7
Digital Sight Series Brochure-8

A microscope digital camera system with selectable combinations of camera head and controller for every application Three models of compact color digital cameras for microscopy are available as camera heads. Two models of controller are available: a stand-alone type with built-in monitor for easy image capture, and a PC-use controlled type that enables advanced image processing and analysis via imaging software. The three camera head models and two controller models can be freely combined to create a system for every purpose. Camera Heads Control Units Stand-alone control unit PC-use control...

 Open the catalog to page 8
Digital Sight Series Brochure-9

Digital camera heads 5.0 megapixel High-denition color camera head The DS-Fi2 is capable of high-resolution 2560×1920 pixel shooting. In addition to a high-speed frame rate of 21 fps*, this model expands the range of settings available for exposure time to adapt to a wider variety of samples. Suitable for a wide range of applications including brighteld, phase contrast, and differential interference, the DSFi2 achieves high functionality and high cost-performance. * When using DS-L3 and FAST mode 2/3" color, 5.0 megapixels, CCD Image sensor Display speed Standalone: 10 fps (2560×1920), max. 37...

 Open the catalog to page 9
Digital Sight Series Brochure-10

Stand-alone control unit Equipped with a large touch panel monitor and a rich feature set, the DS-L3's ease of operation enables quick image acquisition even without a PC or computer monitor. High-denition touch panel monitor Improved image processing performance Built-in 8.4" 1024×768 monitor. Easy to see and easy to use, the large touch-panel monitor allows simple setting and operation of the camera head with a touch of a nger or stylus. The DS-L3 reduces or eliminates diagonal line jaggedness in images and improves color reproduction as well, reducing unevenness in sample colors caused by...

 Open the catalog to page 10
Digital Sight Series Brochure-11

A wide variety of tools The DS-L3 enables the conducting of simple measurements on images, with input of lines and comments. These can also be written onto and saved with the image, and measurement data can be output. The DS-L3 can be controlled via PC using the NIS-Elements software (available separately; see page 12). The DS-L3 can also be used as is for complicated analysis and image processing. Saving and printing functions Measurement function • Measurement [2 point distance, Point to line distance, Circle distance, Angle, Circle (Diameter, Radius), Area, Pitch distance] Saving to a wide...

 Open the catalog to page 11

All Nikon Instruments catalogs and technical brochures

  1. HCA

    8  Pages

  2. DS-Fi3

    16  Pages

  3. TI-E

    32  Pages

  4. ECLIPSE TS2

    8  Pages

  5. ECLIPSE TS2R

    8  Pages

  6. N-SIME

    6  Pages

  7. N-SIM N-STORM

    24  Pages

  8. ECLIPSE Ti2

    24  Pages

  9. Eclipse Ti

    32  Pages

  10. C2 Plus

    16  Pages

  11. SMZ18

    16  Pages

  12. N-SIM E

    4  Pages

Archived catalogs

  1. A1 MP+ / A1R MP

    15  Pages

  2. ShuttlePix

    8  Pages

  3. Eclipse FN1

    12  Pages

  4. MiBrochure

    2  Pages

  5. AZ_C1

    2  Pages

  6. C2+_2CE-SCHH-5

    16  Pages

  7. N-STORM 4.1

    13  Pages

  8. A1_MP

    11  Pages

  9. A1+ / A1R+

    13  Pages

  10. NIS-Elements

    8  Pages

  11. AZ100M

    8  Pages

  12. Eclipse Ni

    15  Pages

  13. AZ100

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.