8204CA
1 /4Pages

8204CA

8204CA
1 /4Pages

Catalog excerpts

8204CA-1

regional oximetry Dual Emitter Regional Oximetry (rSO2 ) Sensor Greater Accuracy and Reliability for Enhanced Patient Outcomes An advancement in near-infrared spectroscopy (NIRS) regional oximetry, the SenSmart Model 8204CA dual emitter regional oximetry sensor for use with the SenSmart Universal Oximetry (rSO2 /SpO2) System, offers clinicians absolute accuracy to optimize patient care. SenSmart Technology offers accurate rSO2 values on all patients…no more guessing when the system doesn’t provide a reading, and no more outliers that misrepresent patients’ true physiologic conditio

 Open the catalog to page 1
8204CA-2

SenSmart rSO2 Technology: Four-Wavelength Optics Greater Accuracy and Reliability through Better Science ™ SenSmart rSO2 Technology utilizes four wavelengths of light to measure the balance of oxyand deoxy-hemoglobin, while compensating for tissue factors that reduce rSO2 accuracy. The result is highly accurate measurements of patients’ true tissue oxygen saturation. Conventional Two-Wavelength, Single-Emitter NIRS Trending Variability1 Nonin rSO2 Technology Four-Wavelength rSO2 Values Aligned with SavO21 80 Percent of Observations in Each Decade Percent of Total Patients rSO2 and SavO2 Decades...

 Open the catalog to page 2
8204CA-3

“Being able to measure absolute values of cerebral tissue oxygen saturation opens new possibilities for the clinician.” Greg Fischer, M.D., Mount Sinai Medical Center, New York SenSmart rSO2 Technology: Dual-Emitter Architecture Effectively Removes Surface Tissue Artifacts ™ Only the patented SenSmart rSO2 sensors use dual emitters and dual detectors to provide repeatable cerebral cortex measurements that are minimally affected by intervening tissue or surface effects.3 Percent Change from Baseline after Occlusion for 5 Minutes (%)3 35% 30% Light Detectors Light Emitter A recent independent,...

 Open the catalog to page 3
8204CA-4

Product Highlights • Absolute Accuracy1 - 4.1 Arms* • Consistent - Repeatable results for maximum efficiency and time savings4 • immediate Response - Near-instant measurements ensure readings from the moment the sensor is placed • Real-time Readings - Sampling rates less than two seconds apart guarantee up-to-date saturation readings SenSmart™ X-100 Universal Oximetry (rSO2/SpO2) System SenSmart™ Model 8204CA Regional Oximetry (rSO2) Sensor Improved rSO2 Sensor Utility • 13% smaller footprint than 8004CA • Quick-connect intermediate cable that can stay connected to signal processor between cases...

 Open the catalog to page 4

All Nonin catalogs and technical brochures

  1. 8000 series

    2  Pages

  2. 6000 C series

    2  Pages

Archived catalogs

  1. Onyx III 9591

    2  Pages

  2. RespSense

    2  Pages

  3. Product Catalog

    21  Pages

  4. Avant 2120

    2  Pages

  5. LifeSense®

    2  Pages

  6. Avant® 9600

    2  Pages

  7. Avant® 9700

    2  Pages

  8. nVision

    4  Pages

  9. LifeSense®

    2  Pages

  10. WristOx2?

    2  Pages

  11. 9840 Series

    2  Pages

  12. Model 7500

    4  Pages

  13. Onyx9550

    4  Pages

  14. Product catalog

    21  Pages

  15. Avant® 9600

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.