Nonin Medical, Inc. conducted a study on the performance characteristics of the Avant 9600 and Avant 9700 devices, focusing on their accuracy under conditions of motion and low perfusion. These devices utilize PureSAT® Signal Processing Technology.

Performance Specifications
  • Saturation Accuracy (%SpO2 + 1 SD): For adults and pediatric patients, the accuracy is ±2 digits without motion and ±2 digits with motion. For neonates, the accuracy is ±3 digits without motion and ±3 digits with motion.
  • Pulse Rate Accuracy: The pulse rate accuracy for adults and pediatric patients is ±3 digits without motion and ±5 digits with motion. For neonates, it is ±3 digits without motion and ±5 digits with motion.
  • Low Perfusion: The accuracy for adults and pediatric patients is ±2 digits, while for neonates, it is ±3 digits.

Testing Procedures
Testing for saturation accuracy in a motion environment was conducted at the Hypoxia Research Laboratory at the University of California, San Francisco. The Radiometer OSM-3 Multi-wavelength CO-oximeter served as the gold standard for accuracy testing. The protocols adhered to common industry practices and involved the use of the Avant 9600 and Avant 9700 with the 8000AA finger clip sensor and the 8000J Flex sensor. Pulse rate motion and low perfusion tests were conducted in-house using an industry-standard simulator.
See more

Catalog excerpts

Avant® 9600-1

Nonin Technical Bulletin Avant® 9600 & Avant 9700 Study Data Performance Characteristics Under Conditions of Motion and Low Perfusion Avant 9600 & Avant 9700 with PureSAT® Signal Processing Technology Saturation Accuracy (%SpO2 + 1 SD) 70-100% No Motion Adults/Peds ± 2 digits Neonates ± 3 digits Motion Adults/Peds ± 2 digits Neonates ± 3 digits Low Perfusion Adults/Peds ± 2 digits Neonates ± 3 digits Pulse rate accuracy 60-240 beats/min No Motion Adults/Peds ± 3 digits Neonates ± 3 digits Motion Adults/Peds ± 5 digits Neonates ± 5 digits Low Perfusion Adults/Peds ± 3 digits Neonates ± 3 digits How was the testing done? Saturation testing in a motion environment was conducted on human subjects at the Hypoxia Research Laboratory (Severinghaus) at the University of California, San Francisco. The Radiometer OSM-3 Multi-wavelength CO-oximeter was used as the gold standard for accuracy testing. Protocols for testing were in line with common industry practices and incorporated the Avant 9600 & Avant 9700 using the 8000AA finger clip sensor and the 8000J Flex sensor. Pulse rate motion and low perfusion were tested in-house, utilizing an industry standard simulator. Nonin Medical, Inc. 13700 1st Avenue North, Plymouth MN 55441-5443 Phone: +1.763.553.9968 • Toll Free: 800.356.8874 Fax: +1.763.553.7807 • Website: www.nonin.com Nonin® is a registered trademark of Nonin Medical, Inc. 07/15/2004 T-0504

 Open the catalog to page 1

All Nonin catalogs and technical brochures

  1. 8204CA

    4  Pages

  2. 8000 series

    2  Pages

  3. 6000 C series

    2  Pages

Archived catalogs

  1. Onyx III 9591

    2  Pages

  2. RespSense

    2  Pages

  3. Product Catalog

    21  Pages

  4. Avant 2120

    2  Pages

  5. LifeSense®

    2  Pages

  6. Avant® 9600

    2  Pages

  7. Avant® 9700

    2  Pages

  8. nVision

    4  Pages

  9. LifeSense®

    2  Pages

  10. WristOx2?

    2  Pages

  11. 9840 Series

    2  Pages

  12. Model 7500

    4  Pages

  13. Onyx9550

    4  Pages

  14. Product catalog

    21  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.