Overview: The document provides detailed specifications and features of the Avant 9700 Pulse Oximeter, a tabletop/portable digital device designed for comprehensive data capture and monitoring of oxygen saturation and pulse rate.
Specifications:
  • Oxygen Saturation Range: 0% to 100% SpO2.
  • Pulse Rate Range: 18 to 300 pulses per minute.
  • Display: Features a 3-digit LED display with tricolor indicators and a 16-color LCD with 256 x 64 pixels.
  • Accuracy: Varies by patient type and conditions (e.g., motion, low perfusion) with specific accuracy levels for adults, pediatrics, and neonates.
  • Environmental Conditions: Operating temperature from +32°F to +122°F, storage from -22°F to +122°F, and humidity from 10% to 95% non-condensing.
  • Power Requirements: Operates on mains power (100-240 VAC) or a 7.2-volt battery pack, providing up to 12 hours of operation.
  • Memory: Stores up to 115 hours of non-volatile data.
  • Dimensions and Weight: Measures 7.25" x 5.5" x 4.5" and weighs 2.4 pounds.
Features:
  • Display and Indicators: The device offers intuitive, color-coded displays for easy monitoring, with waveform color changes indicating pulse signal quality.
  • Alarm Settings: Includes flexible and versatile alarm settings with audible and visual indicators, user-defined defaults, and a nurse call system.
  • Data Management: Compatible with nVISION® Data Management Software for detailed trend analysis and event identification.
  • Portability and Accessories: Offers options for carrying cases, rolling stands, and pole clamps for increased portability.
Technology: Utilizes Nonin’s PureSAT® signal processing technology for improved pulse detection and artifact rejection, ensuring accurate and dependable readings.
Compliance and Quality: The device complies with IEC 60601-1/UL2601-1 standards and is registered to ISO 13485:2003, ensuring high-quality manufacturing and performance.
Conclusion: The Avant 9700 Pulse Oximeter is a versatile, reliable, and user-friendly device suitable for a wide range of clinical settings, from acute care to homecare, providing accurate monitoring of oxygen saturation and pulse rate.
See more

Catalog excerpts

Avant® 9700-1

Pulse Oximetry Specifications Oximeter Oxygen Saturation Range (%SpO2) PureLight® sensors produce the pure light spectrum which eliminates variations in readings from patient-to-patient and sensor-to-sensor. Accurate and dependable SpO2 readings start with PureLight sensors. Nonin’s PureSAT® technology makes greater use of signal charactersitics for artifact rejection, using improved pulse detection technology for faster, more precise pulse detection and quick readings. Pulse Rate Range Displays Numeric Displays 3-digit LED's, Tricolor (red, green, amber) Pulse Strength Indicator Pulse Quality Indicator Accuracya Blood Oxygen Saturation (%SpO2 ±1 SD)b No Motion: Adults, Pediatrics Adults, Pediatrics Neonates Low Perfusion: Adults, Pediatrics Comprehensive Data Capture With integrated SpO2 & heart rate memory, the Avant® 9700 can be used for extended monitoring situations. When used with Nonin’s proprietary software, nVISION®, a clear picture of the trended SpO2 and heart rate data can be reviewed instantly - including the ability to edit parameters for event identification. Sensors & Cables - Use with Nonin's complete line Tabletop/Portable Digital Pulse Oximeter with Waveform Pulse Rate No Motion Temperature Operating Humidity Operating Altitude Operating Select Your Options Power Requirements Mains Internal Power Battery 7.2 volt battery pack (6 cells) of PureLight sensors & cables (Neonate, Infant, Pediatric, Adult) Minimum 12 hours of continuous operation with a fully charged Nurse Call Cable - A variety of cables are available battery pack and LCD backlight off Minimum 8 hours of continuous operation with a fully charged battery pack and LCD backlight on Carrying Case - Convenient for transport and 7.25" wide x 5.5" high x 4.5" deep Weight (excluding Pole Mount System) storage – Avant Series Product Rolling Stand - Standard or deluxe 5 point stand increases portability – Avant Series Product Pole Clamp - Mounts horizontal or vertical – Avant Series Product Output Options - nVISION® Data Management Class I (when on AC power with 300PS-UNIV battery charger) Software for oximetry screening - Portable thermal printer - Digital to Analog Converter Module Type BF-Applied Part Internally powered (on battery power) Nurse Call Maximum Voltage Maximum Load Current Your Partner of Choice With over 18 years of experience and dedication to the design and support of noninvasive monitoring devices, Nonin has helped many medical professionals meet clinical and economic objectives. Trusted by clinicians worldwide, countless tests are performed every day on thousands of Nonin pulse oximeters in more than 125 countries. Nonin's dedication to technological leadership, precision manufacturing and uncompromised customer support ensures quality products and service you expect. Output Impedance Normally Open or Normally Closed; switch selectable Output Connector 0.141” miniature phone jack Accuracy is expressed for adult patients and determined with the Reusable 8000AA Finger Clip Sensor and 8000J Flex Sensor. All accuracy specifications are results determined by induced hypoxia studies on healthy adult volunteers. Motion accuracy specifications apply to the 8000AA Finger Clip Sensor and 8000J Flex Sensor. The low perfusion specifications apply to monitor performance. S.D. (Standard Deviation) is a statistical measure; up to 32% of the readings may fall outside these limits. Quality Systems are registered to ISO 13485:2003 and EC certificates per Annex II, clause 3 of EC Directive No. 93/42/EEC concerning medical devices. Specifications are subject to change without notice. Please contact your authorized distributor for more information. Product Highlights Easy-to-Use - Intuitive, color coded displays Versatile - Monitor neonates to adults; acute care to homecare Powerful - On-demand printing & minimum 8 hour battery life Flexible - Patient Security Mode, Nurse Call & User-Defined Defaults Intelligent - Nonin’s Next Generation PureSAT® signal processing technology Nonin Medical, Inc. 13700 1st Avenue North Plymouth, MN 55441-5443, USA Phone: +1.763.553.9968 Toll Free: 1.800.356.8874 Fax: +1.763.553.7807 [email protected] © 2005 Nonin Medical, Inc. Nonin®, the Nonin Logo®, Avant®, nVISION®, PureLight® and PureSAT® are registered trademarks of Nonin Medical, Inc. P/N 4468-000-05 Where People Make the Difference Convenient - Compact, lightweight & durable Where People Make the Difference

 Open the catalog to page 1
Avant® 9700-2

Distinctive Displays – Dependable Performance The plethysmographic waveform alters color as a real-time reflection of the patient’s pulse signal quality – alerting you to patient changes. The high-resolution color display compliments the signal quality indicators and LED values. The Avant® 9700 combines flexible alarm options, unparalleled non-volatile memory, and Nonin’s time-honored technology to give you an easy-to-use and efficient monitor. On-Screen Trending & Histogram Intuitive Displays The Avant 9700 color LCD offers clear viewing of on-screen trending. The high resolution screen quickly...

 Open the catalog to page 2

All Nonin catalogs and technical brochures

  1. 8204CA

    4  Pages

  2. 8000 series

    2  Pages

  3. 6000 C series

    2  Pages

Archived catalogs

  1. Onyx III 9591

    2  Pages

  2. RespSense

    2  Pages

  3. Product Catalog

    21  Pages

  4. Avant 2120

    2  Pages

  5. LifeSense®

    2  Pages

  6. Avant® 9600

    2  Pages

  7. nVision

    4  Pages

  8. LifeSense®

    2  Pages

  9. WristOx2?

    2  Pages

  10. 9840 Series

    2  Pages

  11. Model 7500

    4  Pages

  12. Onyx9550

    4  Pages

  13. Product catalog

    21  Pages

  14. Avant® 9600

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.