Nonin Capnography Moisture Management Technology

Nonin Capnography Moisture Management Technology

Nonin Capnography Moisture Management Technology

Product catalog summary
Introduction to EtCO2 Technology
EtCO2 technology is crucial for accurate measurement of end-tidal carbon dioxide levels. Traditional methods of moisture removal from sample tubing have posed challenges such as air mixing, bulky designs, and low volume, which can interrupt patient monitoring.
Traditional Moisture Solutions
Conventional water traps used to remove excessive moisture often result in air mixing, leading to lower EtCO2 readings. They are also bulky and prone to breakage, with low volume capacity that can interrupt patient monitoring.
Nonin’s MedAir™ Revolutionary Moisture Solution
Nonin Medical has developed the MedAir™ system, featuring a unique "Flow-Thru" design. This advanced moisture trap eliminates air mixing and offers several benefits:
  • High Capacity Moisture Trap: Ensures uninterrupted patient monitoring and provides unmatched moisture control.
  • Flow-Thru Design: Minimizes air mixing, ensures accurate EtCO2 monitoring, and maximizes moisture removal.
  • Built-in Design: Unobstructed and minimizes leakage.
Applications and Benefits
The MedAir system is suitable for various settings, including pre-hospital, hospital, and sleep labs. It is designed to be simple, cost-effective, and efficient for busy clinical environments.
Instructions for Use
To use the moisture management system:
  1. Place the filter in the moisture trap as shown.
  2. Connect the moisture trap into position.
  3. Press the moisture trap into position by pushing the tab.
  4. To remove the moisture trap and replace the filter, reverse the steps above.
Caution: Filters are single-use and disposable. A new filter must be used for each patient and disposed of after use.
Contact Information
Nonin Medical, Inc.
13700 1st Avenue North, Plymouth, MN 55441-5443, USA
Phone: +1 763.553.9968 | Toll Free: 800.356.8874 | Fax: +1 763.553.7807 | Email: [email protected]
Website: www.nonin.com
See more

Catalog excerpts

Nonin Capnography Moisture Management Technology-1

EtCO2 technology Moisture Management Technology Traditional Moisture Solution Nonin’s MedAir™ Revolutionary Moisture Solution MedAir created a unique “Flow-Thru” design that incorporates an advanced moisture water trap that eliminates air mixing: Mixed Air Exhaled air with water vapor Air mixing Moisture/Water Moisture must be removed from the sample tubing to achieve accurate measurements and to prevent contamination and damage to the device. Conventional water traps introduced additional problems when used to remove excessive moisture: P mixing – resulting in lower EtCO2 Air readings P Bulky external design – prone to breakage P Low volume – interrupted patient monitoring P capacity moisture trap High – Uninterrupted patient monitoring – Offers unmatched moisture control P Flow-thru design – Minimal air mixing – Accurate EtCO2 monitoring – Maximum moisture removal P Built-in design – Unobstructed – Minimizes leakage

 Open the catalog to page 1
Nonin Capnography Moisture Management Technology-2

EtCO2 technology MedAir’s simple, high-capacity moisture management system Our revolutionary “Flow Thru” design makes using capnography simple and effective. Whether it’s used in the pre-hospital, hospital or sleep lab setting, our moisture management system is the best, most cost-effective and simplest solution for today’s busy clinical environment. 1 Instruction for use: P Place the filter in the moisture trap as shown in 1 . 2 P Connect the moisture trap into position as shown in 2 . P Then press the moisture trap into position, by pushing the tab, as shown in 3 . P remove the moisture trap...

 Open the catalog to page 2

All Nonin catalogs and technical brochures

  1. 8204CA

    4  Pages

  2. 8000 series

    2  Pages

  3. 6000 C series

    2  Pages

Archived catalogs

  1. Onyx III 9591

    2  Pages

  2. RespSense

    2  Pages

  3. Product Catalog

    21  Pages

  4. Avant 2120

    2  Pages

  5. LifeSense®

    2  Pages

  6. Avant® 9600

    2  Pages

  7. Avant® 9700

    2  Pages

  8. nVision

    4  Pages

  9. LifeSense®

    2  Pages

  10. WristOx2?

    2  Pages

  11. 9840 Series

    2  Pages

  12. Model 7500

    4  Pages

  13. Onyx9550

    4  Pages

  14. Product catalog

    21  Pages

  15. Avant® 9600

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.