Nonin Onyx Finger Puise Oximeters
6Pages

{{requestButtons}}

Catalog excerpts

Nonin Onyx Finger Puise Oximeters - 1

Nonin Onyx Finger Pulse Oximeters ® Superior Performance…For Challenging Patient Conditions

Open the catalog to page 1
Nonin Onyx Finger Puise Oximeters - 2

COPD patients often present with complex co-morbidities As a clinician who treats patients with Chronic Obstructive Pulmonary Disease (COPD), making the right decision is often dependent on getting an accurate oxygen saturation (SpO2) reading. Getting accurate readings can be more difficult in COPD patients with cardiovascular co-morbidities, such as congestive heart failure (CHF). Up to 27% of COPD patients may also have congestive heart failure1 COPD patients with CHF can challenge oximeter accuracy Poor blood circulation Drops in oxygen levels (desaturation) • Poor blood circulation is a...

Open the catalog to page 2
Nonin Onyx Finger Puise Oximeters - 3

Superior technology for challenging conditions...including rapid SpO21 changes, poor peripheral blood circulation and motion The inventor - Nonin developed finger pulse oximetry and has over 25 years of clinical experience. Peer-reviewed accuracy, FDA-cleared - The accuracy and performance of the Onyx finger oximeter is supported by published, peer-reviewed clinical studies. U.S. military certified2 - The only finger pulse oximeter that has airworthiness approval for use in military aircraft. PureSAT® SpO2 technology The only oximeter with pulse-by-pulse filtering -Nonin Medical's...

Open the catalog to page 3
Nonin Onyx Finger Puise Oximeters - 4

Nonin Onyx – accuracy and durability in ® Only Nonin’s finger oximeter2was able to track the subject’s desaturation5 SpO Values Over Time Only Nonin Onyx® and Nellcor™ pulse oximeters accurately tracked the subject's desaturation. (False High) (False High) Control6 Nonin Onyx Nonin Nellcor Onyx Oximeter A Oximeter A SpO2 saturation values you can trust • Nonin PureSAT technology uses pulse-by-pulse filtering to provide accurate SpO2 measurements. The leading competitors use measurement averaging across numerous pulses which can result in delayed or inaccurate readings during saturation...

Open the catalog to page 4
Nonin Onyx Finger Puise Oximeters - 5

challenging patient conditions Accuracy in poor peripheral (finger) blood circulation Figure 1: Nonin Onyx Vantage is accurate in patients with as low as 0.3% pulse signal strength.7 Normal Pulse Strength (3%)8 Superior durability A normal arterial pulse wave form showing the systolic peak (in red). Nonin Onyx Vantage can read pulse strength in patients with poor circulation (in blue) even when it is as low as 1/10th the strength of a normal wave form. Figure 2: Nonin Onyx versus Competitors after drops from the same height (1 meter).7 Drop durability – After 50 drops from 1 meter onto a...

Open the catalog to page 5
Nonin Onyx Finger Puise Oximeters - 6

Onyx® Vantage 9590 Finger Pulse Oximeter Finger Pulse Oximeter CMS50DL Finger Pulse Oximeter Manufacturer Manufacturing location Warranty Latex-free* Lead-free** UL approved as medical device RoHS*** compliant Manufacturer provides published independent proof sources for claims Tested in motion Accuracy claims in dark skin pigmentation Customer service and technical support Nonin Medical Plymouth, MN, USA 4-year warranty Yes Lead Free Yes Yes Yes Yes Beijing Choice Beijing, China 1-year limited warranty Unknown Contains Lead-Rich Components No No Contec Medical Qinhuangdao, China 1-year...

Open the catalog to page 6

All Nonin catalogs and technical brochures

  1. 8204CA

    4 Pages

  2. 8000 series

    2 Pages

  3. RespSense

    2 Pages

  4. Avant 2120

    2 Pages

  5. LifeSense®

    2 Pages

  6. 9840 Series

    2 Pages

  7. Avant® 9600

    2 Pages

  8. Avant® 9700

    2 Pages

  9. nVision

    4 Pages

  10. LifeSense®

    2 Pages

  11. WristOx2?

    2 Pages

  12. Model 7500

    4 Pages

  13. Onyx9550

    4 Pages

Archived catalogs

  1. Avant® 9600

    1 Pages