1. Catalogs
  2. Nonin
  3. System Story Brochure Old

System Story Brochure Old

System Story Brochure Old

System Story Brochure Old

Product catalog summary
Overview
Nonin Medical emphasizes the importance of using their PureSAT® pulse oximeters in conjunction with PureLight® sensors to ensure accurate, consistent, and reliable SpO2 readings across a wide range of patients and settings. This includes patients with varying skin pigmentation, from neonates to adults, and in conditions involving motion and low perfusion.

Specifications and Technology
Nonin's PureLight sensors emit pure LED light, eliminating variations in readings due to impure light emissions that can affect calibration, especially at SpO2 levels below 80%. The PureSAT technology uses advanced signal processing to filter out noise and artifacts, ensuring accurate readings even during patient movement or low perfusion.

Clinical Accuracy
Nonin's pulse oximetry systems are clinically proven to provide accurate SpO2 readings, crucial for assessing hypoxia events, critical interventions in acute care, and home monitoring. The systems comply with ISO Standards 9919:2005 for pulse oximetry, emphasizing the importance of using compatible probes and cables.

Risks of Incompatibility
Using Nonin oximeters with non-Nonin sensors can lead to inaccurate data, under-reporting of hypoxic events, increased false alarms, and the need for repeated diagnostic studies. This can compromise patient safety and lead to additional costs.

Product Range
Nonin offers a variety of pulse oximeters, including handheld, tabletop, and wrist-worn models, compatible with different sensor types such as clip, cloth, and flexi-form sensors.

Conclusion
Nonin Medical's pulse oximetry systems are designed to provide uncompromising accuracy and reliability, ensuring patient safety across diverse clinical settings.
See more

Catalog excerpts

System Story Brochure Old-1

Don’t Compromise Patient conditions can be unpredictable. Pulse oximeter safety and accuracy shouldn’t be. Using Nonin PureSAT® pulse oximeters together with Nonin PureLight® sensors is the only way to ensure you’re getting clinically proven SpO2 accuracy, consistency and reliability in the widest range of patients and settings. From light skin to dark skin. Neonates to adults. With motion and low perfusion. In sleep labs, hospitals and homes. Patient to patient, Nonin Medical’s complete pulse oximetry systems are uncompromising.

 Open the catalog to page 1
System Story Brochure Old-2

DID YOU KNOW? Mixing Nonin oximeters with other manufacturers’ sensors compromises Nonin’s clinically proven accuracy — and could compromise patient safety. Beware of sensors claiming to be compatible with Nonin pulse oximeters. Nonin PureSAT oximeters are validated and cleared for use only with Nonin PureLight sensors, providing accurate readings for assessing: • Hypoxia events related to potential sleep disorders • Patients needing critical intervention in acute care settings • Patients being monitored at home Accuracy and safety depend on the complete pulse oximetry system performance. ISO...

 Open the catalog to page 2
System Story Brochure Old-3

Industry-Leading Accuracy2 Masimo Nellcor NONIN n Nonin n Nellcor n Masimo Dark Skin Pigmentation Less Accurate More Accurate Nonin demonstrates superior accuracy in the most challenging conditions (e.g.,dark skin pigmentation). Nonin PureSAT pulse oximetry technology uses pulse-by-pulse filtering to provide precise oximetry measurements — even in the presence of motion, low perfusion, and other conditions. By reading the entire plethysmographic waveform, PureSAT signal processing prefilters the pulse signals to remove undesirable signals. Advanced algorithms then separate the pulse signals from...

 Open the catalog to page 3
System Story Brochure Old-4

The Nonin System. Uncompromising. If you mix and match Nonin sensors and oximeters with other manufacturers’ products, you risk: PalmSAT® 2500 Handheld Pulse Oximeter with 8000AA Clip Sensor Under-reporting hypoxic events due to inaccuracy, which could result in: n Missed episodes of hypoxia during continuous monitoring n Qualified patients being incorrectly disqualified for oxygen therapy n Under or missed treatment for hypoxic events n Increased false alarms l Having to repeat diagnostic studies (and incur related costs) due to signal drop out or excessive noise l 7500 Tabletop Pulse Oximeter...

 Open the catalog to page 4

All Nonin catalogs and technical brochures

  1. 8204CA

    4  Pages

  2. 8000 series

    2  Pages

  3. 6000 C series

    2  Pages

Archived catalogs

  1. Onyx III 9591

    2  Pages

  2. RespSense

    2  Pages

  3. Product Catalog

    21  Pages

  4. Avant 2120

    2  Pages

  5. LifeSense®

    2  Pages

  6. Avant® 9600

    2  Pages

  7. Avant® 9700

    2  Pages

  8. nVision

    4  Pages

  9. LifeSense®

    2  Pages

  10. WristOx2?

    2  Pages

  11. 9840 Series

    2  Pages

  12. Model 7500

    4  Pages

  13. Onyx9550

    4  Pages

  14. Product catalog

    21  Pages

  15. Avant® 9600

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.