Catalog excerpts
Complete Products and Solutions USA, CANADA, SOUTH AMERICA NordicNeuroLab Inc. 234 W. Florida St. Suite 210 Milwaukee, WI 53204, USA Phone: +1.262.337.0922 Fax: +1.262.244.3225 ASIA NordicNeuroLab 230/5F 260 Songpa-daero, Songpa-gu Jeil Officetel Bldg, Garak-dong 138-715 Seoul, South Korea Phone: +82 2 2043 6909 Fax: +82 2 2043 6809 General Information info@nordicneurolab.com Sales Inquiries sales@nordicneurolab.com Website www.nordicneurolab.com Scan QR code for more information
Open the catalog to page 1Advanced Hardware and Software
Open the catalog to page 2fMRI Hardware Our hardware portfolio consists of equipment designed for functional magnetic resonance imaging. We offer a complete hardware package for clinical fMRI and a modular solution for research purposes. Our hardware is compatible with MRI scanners from all major vendors and uses standardised interface adapters for audio and visual input. Our fMRI hardware system is designed, developed and manufactured under certified ISO 13485 and ISO 9001 Quality Management system. Our products intended for clinical use meet regulatory and safety requirements and have respective market clearances....
Open the catalog to page 3InroomViewingDevice For fMRI, patient comfort and instant feedback Multipurpose Usage NordicNeuroLab InroomViewingDevice was designed to provide an optimal MRI compatible monitor that satisfies the needs of both clinical and advanced scientific applications. It has been certified by Siemens for both fMRI and general use, and fulfills Siemens’ requirements of relative change of background noise (increase) less than 1% and no image RF artefacts (for 1.5T and 3T). Optimal Design With its slim design, high definition display and superior image quality, the InroomViewingDevice is an optimal...
Open the catalog to page 4VisualSystem High-end visual stimulation for fMRI Sophisticated and Flexible NordicNeuroLab VisualSystem is a sophisticated and flexible solution for presenting visual stimuli inside the MRI scanner. By rendering sharp images and brilliant colours, high quality graphics or text is easily presented to the patient. Separate displays for each eye permits both 3D and stereo stimuli. Unique Design The VisualSystem has a unique design which fits most head coils and is easy to mount with coil specific adapters. The adjustable arm allows fast positioning in the preferred angle of view. The builtin...
Open the catalog to page 5AudioSystem Audio solution for fMRI State-of-the-art Properties The headphones give a superb sound, replicating even minute details with incredible precision, thanks to the state-of-the-art electrostatic transducers. The device significantly reduces scanner noise, allowing undisturbed patient communication during stimuli presentation. Designed for fMRI - Suited for Clinical Use Designed specifically for fMRI, the superior sound quality and increased noise attenuation provides a more precise audio stimulation to the patient, which yields a more robust BOLD response than traditional pneumatic...
Open the catalog to page 6ResponseGrip A unique patient response device Developed for Clinical and Research Use The ResponseGrip is an MRI compatible subject response device developed for both clinical and research users. Ergonomically designed for use in either hand and for minimizing patient movement inside the scanner, it is suitable for a wide range of experimental paradigms. The ResponseGrip is compatible with all leading stimulus presentation software packages, and interfaces with a number of third-party hardware devices. Interface Unit The ResponseGrip is 100% fibre optic, and connects to the ResponceGrip...
Open the catalog to page 7SyncBox Simple solution for accurate control over stimulus presentation One of the challenges in fMRI is synchronising stimulus presentation with MR image acquisition. The accuracy and verification of timing information is critical to the validity of results. With a flexible and user-friendly menu system, the SyncBox allows the user to select how the trigger pulse from the scanner is transferred to the software presenting the stimuli. Compatible with the leading software packages, the SyncBox provides a simple solution for accurate control over stimulus presentation and easy access to...
Open the catalog to page 8fMRI Software NordicNeuroLab provides solutions for the analysis of advanced neuroimaging for MRI. This includes: • stimulus presentation software • fast and easy to use post-processing software for BOLD fMRI, DTI and Perfusion analysis • research-oriented software for post-processing advanced neuroimaging for MRI Our main focus is to provide clinical users with easy to use tools for optimising workflow and minimising processing time. In this way we improve productivity and offer research users sophisticated and advanced solutions for neuroimaging.
Open the catalog to page 9nordicAktiva Stimulus presentation and workflow software Easy stimulus generation and image acquisition Ready-to-use standard clinical paradigm library By using nordicAktiva a single technician can handle stimulus generation and image acquisition at the same time. It offers a choice of either using pre-defined paradigms, modifying them based on user preferences, or simply building a tailored library. nordicAktiva also supports video files. Visual output can be flipped/mirrored vertically and/or horisontally. The user is guided step-by-step through the process of presenting stimuli during...
Open the catalog to page 10nord icBrainEx Streamlined BOLD fMRI, DTI and Perfusion analysis BOLD fMRI Neuroimaging software for fMRI Designed for the clinical workflow Our simple and user-friendly interface improves user productivity. Advanced volume of interest tools, combined with 2D / 3D visualisation of BOLD activation areas, DTI tractography and MRI Perfusion maps allow clinicians to perform extensive evaluations of brain tissue surrounding pathological areas. nordicBrainEx is DICOM compatible and capable of analyzing data from all major MRI vendors. All processed data can be saved in a comprehensive report,...
Open the catalog to page 11Optimised workflow More time for your patient Optimise your workflow in 3 simple steps Select patient and image series Export to PACS / neuronavigation