Cardiac catheterization laboratories and cardiovascular hybrid room with high aseptic conditions for hybrid interventions The primary objective of Operio hospital operating room (OR) ventilation system is to minimize surgical site infection due to airborne contaminants and bacteria. Operio Sterile Air Flow units create OR-like sterile conditions that were previously only possible in an expensive operating theatre. Mobile Operio laminar air flow systems enable cost-effective upgrading of existing cardiac catheterization laboratory and cardiac cath (heart cath) . Operio create an asepsis for the instruments and operating area (and that’s what matters!) that is up to 100 times higher than in a conventional cardiac catheterization laboratory, because the sterile air flow directly and immediately protects the instruments and the operating area without obstructions – such as the operating microscope or the operating team. The Operio Sterile Air Flow unit filters the ambient air through a highly purifying H 14 Hepa filter with an efficiency of over 99.9%, which eliminates bacteria and micro-organisms (including coronavirus covid 19) by over 99.9%! These units can be positioned to produce a “bacteria-free zone” that offers the greatest possible protection for both the surgical team and the patient, in that they filter 400 m3 of air per hour, thus reducing microorganisms in the entire room. The entirety of a standard practice area of 40 m3 will be completely filtered every 6 mi

Open the catalog to page 1
cardiac catheterization laboratory and Cardiovascular Hybrid Operating Room - 2

Focus laminar air flow operating room The focus-oriented, mobile laminar air flow devices generate an ultraclean, germ-free air flow by filtering the air with a Hepa H14 filter, which can be aimed precisely at the desired operating field area. The “sterile air flow” is not hindered neither by the operating theater lights nor by the operating theater team. In this way, extremely low-germ air can be created in the area of the operating theater and the instruments, which makes it possible to operate under perfectly hygienic conditions Conventional air flow systems Umbrella effect: the C-arm...

Open the catalog to page 2
cardiac catheterization laboratory and Cardiovascular Hybrid Operating Room - 3

Technical specifications The Operio devices are extremely small and handy and can also be used in very small rooms. The removable instrument table from Operio is available in various lengths of 45 cm (for intravitreal injections), 60 cm (for ophthalmic operations and intravitreal injections) and 75 cm (for operations that require a lot of instruments). The electrical height adjustment can be carried out by the sterile OR staff (using a sterile covered display) as well as by the other OR staff using a separate display. There is no need to purchase a separate instrument table for storing the...