Introduction
The document outlines the use of the Operio sterile OP-Air Flow device, which creates aseptic conditions for eye surgeries, including intravitreal injections. It utilizes Hepa H 14 filters to purify air, ensuring a 99.995% reduction in bacteria and microorganisms, making it suitable for use outside conventional operating rooms.

Device Features and Benefits
The Operio device is noted for its pleasant air flow, comparable noise level to a beamer, and cost-effectiveness, with amortization possible after a few days of surgery. It provides aseptic conditions up to 100 times higher than conventional operating rooms, crucial for preventing postoperative infections like endophthalmitis.

Applications
The device is applicable for various ophthalmic surgeries, including cataract, glaucoma, refractive, and laser surgeries. It enhances personal protection for surgeons and staff, especially during the Covid-19 pandemic.

Technical Specifications
Operio devices are compact, with removable instrument tables available in different lengths. They feature a 2-stage filtering system (F7 and H14 Hepa filter) achieving ISO 5 cleanliness. The devices are CE marked and comply with several medical device standards.

Performance and Studies
Studies demonstrate significant reductions in particle counts and bacterial colonies in surgical fields, confirming the device's efficacy in maintaining sterile conditions. The device's mobility and affordability allow for quick upgrades of existing operating theaters.

Conclusion
The Operio sterile Air Flow device offers a high level of asepsis for ophthalmic surgeries, ensuring patient and staff safety while being cost-effective and adaptable to various surgical environments.
See more

Catalog excerpts

Guidelines for Intravitreal Injections-1

Guidelines for Intravitreal Injections Operio generates on the instruments and in the operating field aseptic conditions that is up to 100 times higher than in a conventional operating room for eye surgery. The sterile air flow is directly directed to the instruments and the surgical field without any obstacles such as the surgical microscope or the surgical team and hence creates an extreme high level of asepsis which was so far hardly obtainable! The sterile OP-Air Flow device Operio enables inexpensive aseptic conditions to be created for operations and intravitreal injections in eye surgery. The devices work with high-purifying Hepa H 14 filters which purify the air in the operating room and on the instruments practically completely (99.995%) of bacteria and other microorganisms. Intravitreal injections can also be carried out outside of a conventional operating room in the outpatient area with maximum safety for the patient and the operating team. This sterile Air Flow is perceived by the staff as very pleasant because it does not generate cold air. The noise level is comparable to a beamer. Intravitreal injection: the devices are usually amortized after only a few days of surgery. This sterile Air Flow is perceived by the staff as very pleasant because it does not generate cold air. cataract- surgery

 Open the catalog to page 1
Guidelines for Intravitreal Injections-2

Prevention of postoperative infections in ophthalmic surgery Operio sterile Laminar Air flow unit for Ophthalmic Operating Theatre eliminates over 99.9% of all bacteria’s during surgery also Covid-19 and other microorganisms. Postoperative endophthalmitis is typically caused by the perioperative introduction of microbial organisms during surgery. Operio sterile Air Flow: the device works with high-purifying Hepa H 14 filters which purify the air in the operating room and on the instruments practically completely (99.9%) of bacteria, viruses (also coronavirus SARSCoV-2) and other microorganisms....

 Open the catalog to page 2
Guidelines for Intravitreal Injections-3

Traditional air flow ceilings only work very limited Operio: prepare the instruments protected With Operio, the instruments and implants can always be prepared in the protected area with the sterile Air Flow device. Then the operating instrument table is simply moved to the operating area and the protection area is then expanded to include also the operating area. An ultra-clean airflow from the ceiling downward may convey airborne particles from the surgical team into the wound, thus increasing the risk of infection. The mobile clean air zone unit ensures that the surgical site and instruments...

 Open the catalog to page 3
Guidelines for Intravitreal Injections-4

Technical specifications The Operio devices are extremely small and handy and can also be used in very small rooms. The removable instrument table from Operio is available in various lengths of 45 cm (for intravitreal injections), 60 cm (for ophthalmic operations and intravitreal injections) and 75 cm (for operations that require a lot of instruments). The electrical height adjustment can be carried out by the sterile OR staff (using a sterile covered display) as well as by the other OR staff using a separate display. There is no need to purchase a separate instrument table for storing the instruments....

 Open the catalog to page 4

All Normeditec catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.