How to Prevent Endophthalmitis in Cataract Surgeries : Endophthalmitis is one of the most serious postoperative complications in cataract surgery, often leading to irreversible vision loss if not promptly treated. Although rare, its potential severity demands rigorous prevention strategies. Modern techniques, sterile protocols, and air purification technologies now allow eye care providers to significantly reduce the risk of this sight-threatening condition. Creating Cleanroom Conditions with Operio A powerful advancement in infection prevention is the use of mobile laminar air flow units, such as the Operio system. These systems: •Provide ISO 5-level sterility directly to the surgical field and instruments •Remove 99.995% of airborne bacteria and viruses •Ensure uninterrupted, targeted sterile airflow unaffected by microscopes or staff •Achieve a sterile zone within 2 minutes, making them ideal for high-volume cataract clinics The Operio system eliminates the need for major HVAC upgrades, making it especially effective for office-based surgeries and small procedure rooms. Its HEPA H14 filters trap particles as small as 0.3 μm—well below the size of most microorganisms—thereby creating an aseptic barrier around both the instrument table and surgical site. Creating a Sterile Environment with Operio Traditional HVAC systems used in surgery centers are often large, expensive, and susceptible to airflow disruptions caused by surgical lights, microscopes, or staff movement. These interruptions can increase the risk of contamination during critical procedures. Postoperative endophthalmitis is typically caused by microbial contamination introduced during surgery. Operio Mobile Laminar Air Flow is a compact, mobile, and highly efficient alternative that solves these issues by: •Delivering ISO 5 ultra-clean air directly to the surgical field and instrument table •Eliminating 99.995% of airborne contaminants including bacteria and viruses •Maintaining continuous sterile conditions throughout the procedure, even with movement in the room •Sterilizing the field in just 2 minutes, making it ideal for high-volume practices Its focused airflow system is not obstructed by surgical equipment or personnel, ensuring consistent protection of both instruments and the surgical site. Office Surgery Meets Cleanroom Standards By integrating the Operio system into the office setting, practices can now achieve: Hospital-grade sterility without the need for costly HVAC retrofitting. Reduced infection risk, particularly in procedures like intravitreal injections where contamination can lead to serious complications. Quiet, cold-air-free operation, enhancing patient and surgeon comfort. Plug & play setup that requires no structural changes—just a standard power socket. This solution transforms even small procedure rooms into ultra-clean environments suitable for advanced eye surgery. More information internet page Normeditec
Open the catalog to page 1Limitations of Conventional Operating Room Ventilation Systems Traditional ceiling-mounted ventilation systems often fail to provide consistent protection over the surgical field during procedures. Despite being designed to maintain a sterile environment, their effectiveness is frequently compromised due to airflow obstructions from: Surgical lights Ceiling-mounted microscopes Operating room staff movement Traditional vertical airflow systems in operating theatres can increase the risk of bacterial contamination by directing air over the surgical team’s heads and towards the open surgical site....
Open the catalog to page 2y Budget-Friendly: Saves hospitals and clinics thousands by eliminating the need for costly air purification systems y Plug & Play Setup: Runs on standard power sockets—perfect for outpatient and ophthalmic centers y Adjustable Instrument Table: Available in 45cm, 60cm, and 75cm sizes for diverse surgical needs y Energy-Efficient: Uses only 290W, reducing operational costs significantly y Silent Performance: Ensures a distraction-free surgical environment
Open the catalog to page 3Optimized Efficiency & Safety for IVOM with Operio Mobile Laminar Air Flow The Ideal Solution for Intravitreous Injections (IVOM) Intravitreous injections (IVOM) are among the most frequently performed procedures in ophthalmology and demand the highest hygiene standards to minimize the risk of complications such as endophthalmitis. The Operio Mobile Laminar Air Flow system provides an innovative, sterile air solution that enhances efficiency and patient safety by creating a continuously aseptic surgical field. Challenges in IVOM Procedures High Patient Turnover: IVOM procedures involve short,...
Open the catalog to page 4Compact and Flexible Solutions for Sterile Operating Room Condition The Operio Mobile Laminar Air Flow system stands out for its compact design and versatility, making it an efficient solution even in the smallest operating rooms. . Adjustable Instrument Table for Every Surgical Need: Available in three sizes: •45 cm – Ideal for minor procedures. •60 cm – Suitable for standard surgeries. •75 cm – Perfect for complex procedures requiring extensive instrumentation. Removable functionality – Eliminates the need for an additional instrument table. User-Friendly Operation: Electric height adjustment...