video corpo

Laminar airflow ventilation systems in orthopaedic operating room
1 / 9Pages

Catalog excerpts

Laminar airflow ventilation systems in orthopaedic operating room - 1

Laminar airflow ventilation systems in orthopaedic operating roomOperio Mobile Laminar Air Flow & SteriStay Instrument Table Transforming ISO 7 Operating Rooms into ISO 5 Cleanroom Orthopedic procedures, particularly hip and knee prosthesis surgeries, require the highest level of sterility to prevent surgical site infections (SSIs) and ensure long-term implant success. Traditional ISO 7 operating rooms often fail to provide consistent ultra-clean conditions, as airborne contaminants can settle on instruments, implants, and the surgical site, increasing the risk of perioperative infections. To address these challenges, the Operio Mobile Laminar Air Flow System and SteriStay Instrument Table introduce a game-changing approach to orthopedic surgery. By delivering ISO 5 ultra-clean air directly to the surgical field and instrument table, this innovative system creates a highly sterile environment, minimizing contamination risks and ensuring optimal surgical outcomes. Unlike conventional ceiling-based ventilation systems, which can be obstructed by surgical lights, medical staff, and equipment, Operio’s focused sterile airflow provides uninterrupted protection where it matters most. Combined with the SteriStay Instrument Table, which maintains sterility for prosthetic implants and surgical tools, this system enables hospitals and ambulatory centers to perform orthopedic procedures with the highest infection control standards. By upgrading existing ISO 7 operating rooms to ISO 5 conditions, Operio and SteriStay offer a cost-effective, portable, and highly efficient solution for modern orthopedic surgery. This technology is essential for hospitals looking to enhance patient safety, improve surgical efficiency, and reduce infection-related costs without the need for expensive structural modifications. Operio Mobile Laminar Air Flow read more Steristay the first instrument table with integrated hepa filter read more Internetpage Normeditec Contact us for more information Normeditec – Nordic Medical Tecnology Phone : +39 348 730 24 45 Italy +49- 7139/20 90 85 9 Germany E-Mail: info@normeditec.com WhatsApp: +39 348 730 24 45 or +49 176 62 13 16 34 Website: www.normeditec.com We deliver worldwide and are available via video call for support and guidance. Let’s make advanced aseptic solutions accessible to your practice tod

Open the catalog to page 1
Laminar airflow ventilation systems in orthopaedic operating room - 2

Operio Mobile Laminar Air Flow Operio Mobile Laminar Air Flow ensures ISO 5 ultra-clean air for orthopedic surgeries, protecting implants, instruments, and the surgical site from airborne contamination. Its targeted sterile airflow reduces infection risks, enhances patient safety, and upgrades operating rooms from ISO 7 to ISO 5 without costly renovations. The unit can be operated directly by the sterile staff via a sterile cover or from the unsterile side, ensuring seamless integration into the surgical workflow. Additionally, Operio is equipped with a traceability system that registers...

Open the catalog to page 2
Laminar airflow ventilation systems in orthopaedic operating room - 3

Limitations of Conventional Operating Room Ventilation Systems Traditional ceiling-mounted ventilation systems often fail to provide consistent protection over the surgical field during procedures. Despite being designed to maintain a sterile environment, their effectiveness is frequently compromised due to airflow obstructions from: Surgical lights Ceiling-mounted supply units Operating room staff movement Traditional vertical airflow systems in operating theatres can increase the risk of bacterial contamination by directing air over the surgical team’s heads and towards the open surgical...

Open the catalog to page 3
Laminar airflow ventilation systems in orthopaedic operating room - 4

Steristay – The World’s First Instrument Table with Integrated HEPA Filtration Many operating rooms are equipped with undersized air supply ceilings (ZLD) that fail to cover the entire surgical field and instrument preparation area. This is particularly problematic in orthopedic and trauma surgery, where strict hygiene standards are essential to prevent joint infections following hip and knee prostheses. The Challenge: High Microbial Load in Long Surgeries In trauma, cardiac, neurosurgery, thoracic, and transplant procedures, surgeries can last for several hours. During this time,...

Open the catalog to page 4
Laminar airflow ventilation systems in orthopaedic operating room - 5

SteriStay: The First Instrument Table with Integrated HEPA Filtration SteriStay Instrument Table: Advanced Sterility with HEPA Filtration The SteriStay sterile instrument table filters ambient air using a high-performance H14 HEPA filter with an efficiency of over 99.995%, effectively eliminating bacteria, microorganisms, and even COVID-19 by more than 99.9%. Uncompromised Sterility for Surgical Instruments & Implants Ensures continuous sterility during both preparation and the entire surgical procedure. Features a 3-stage filtration system (F7, LAF filter, and H14 HEPA filter) for maximum...

Open the catalog to page 5
Laminar airflow ventilation systems in orthopaedic operating room - 6

SteriStay: Revolutionizing Sterility in Traumatology Ensuring Maximum Infection Control in Trauma Surgery Challenge: High Microbial Load in Long Surgeries & Unprotected Implants In trauma surgery, numerous instruments, screws, and implants remain exposed on the instrument table for extended periods, significantly increasing the risk of contamination. This is especially critical during complex osteosynthesis procedures and revision surgeries, where maintaining sterility is essential. Studies show that instruments placed outside the laminar airflow zone in the OR quickly accumulate microbial...

Open the catalog to page 6
Laminar airflow ventilation systems in orthopaedic operating room - 7

SteriStay in Orthopedics: Maximum Sterility for Knee and Hip Prostheses The SteriStay instrument table ensures continuous sterility for knee and hip prosthesis surgeries, providing ultra-clean, HEPA-filtered air over implants and instruments. This reduces microbial contamination and minimizes the risk of periprosthetic joint infections, which are among the most severe complications in orthopedic surgery. 99.995% filtration efficiency with H14 HEPA filters Protects implants and instruments throughout the entire procedure Reduces microbial load in the surgical field by up to 90% Optimized...

Open the catalog to page 7
Laminar airflow ventilation systems in orthopaedic operating room - 8

Compact and Flexible Solutions for Sterile Operating Room Condition The Operio Mobile Laminar Air Flow system stands out for its compact design and versatility, making it an efficient solution even in the smallest operating rooms. . Adjustable Instrument Table for Every Surgical Need: Available in three sizes: •45 cm – Ideal for minor procedures. •60 cm – Suitable for standard surgeries. •75 cm – Perfect for complex procedures requiring extensive instrumentation. Removable functionality – Eliminates the need for an additional instrument table. User-Friendly Operation: Electric height...

Open the catalog to page 8