Catalog excerpts

Steristay – The World’s First Instrument Table with Integrated HEPA Filtration Many operating rooms are equipped with undersized laminar air flow (LAF) ceilings, which do not adequately cover the entire surgical field and instrument preparation area. This issue is particularly critical in cardiac surgery, where procedures are long in duration, involve large surgical teams, and are performed on patients with weakened immune systems, increasing the risk of airborne contamination and postoperative infections. read more In trauma, cardiac, neurosurgery, thoracic, and transplant procedures, surgeries can last for several hours. During this time, instruments, screws, and implants remain exposed on the instrument table, increasing the risk of contamination. The Solution: Continuous Sterile Protection with SteriStay The mobile SteriStay instrument table, also known as the “Silent Nurse” or “Supply Table”, ensures a consistently sterile environment for instruments and implants throughout the entire procedure. SteriStay: Setting New Standards in Sterile Surgery First-of-its-kind instrument table with a 3-stage HEPA filtration system Prevents contamination of instruments and implants, ensuring continuous sterility Reduces surgical times by optimizing the sterile workflow Extends the protective area in ORs with limited air supply coverage Flexible, cost-efficient, and ready for immediate use . With SteriStay, hospitals can elevate their infection control measures, ensuring safer surgeries, improved patient outcomes, and optimized operating room efficiency. Instrument Contamination During Surgery – The Impact of Ventilation Systems Studies confirm that the choice of ventilation system plays a crucial role in maintaining the microbiological purity of surgical instruments. In turbulently ventilated operating rooms (ISO Class 7), the microbial load on instruments can be up to 150 times higher than in the protected area under a (Laminar Airflow) ceiling (ISO Class 5). Additionally, microbial contamination outside the airflow coverage area is up to 55 times higher than within the protected zone of the laminar air flow ceiling, significantly increasing the risk of instrument contamination and post-operative infections. Ultimate Sterility for Surgical Instruments read more 88% lower contamination risk compared to conventional instrument tables in the OR. 39x reduction in microbial load thanks to integrated TAV laminar airflow. Continuous sterility for surgical instruments and implants, ensuring maximum infection control. By integrating SteriStay, hospitals can significantly enhance surgical hygiene, reduce infection rates, and improve patient safety—setting a new standard in sterile surgery. Internetpage Normeditec
Open the catalog to page 1
SteriStay: The First Instrument Table with Integrated HEPA Filtration SteriStay Instrument Table: Advanced Sterility with HEPA Filtration The SteriStay sterile instrument table filters ambient air using a high-performance H14 HEPA filter with an efficiency of over 99.995%, effectively eliminating bacteria, microorganisms, and even COVID-19 by more than 99.9%. Uncompromised Sterility for Surgical Instruments & Implants Ensures continuous sterility during both preparation and the entire surgical procedure. Features a 3-stage filtration system (F7, LAF filter, and H14 HEPA filter) for maximum...
Open the catalog to page 2
Compact and Flexible Solutions for Sterile Operating Room Condition The Operio Mobile Laminar Air Flow system stands out for its compact design and versatility, making it an efficient solution even in the smallest operating rooms. . Adjustable Instrument Table for Every Surgical Need: Available in three sizes: •45 cm – Ideal for minor procedures. •60 cm – Suitable for standard surgeries. •75 cm – Perfect for complex procedures requiring extensive instrumentation. Removable functionality – Eliminates the need for an additional instrument table. User-Friendly Operation: Electric height...
Open the catalog to page 3
Data Value Certified Safety and Standards The Operio devices are CE-marked and meet the highest medical device standards: V 2007/47 EEC and additional directives such as EN 60601-1-2:2014 and EN ISO 13485:2012 •S DIN 1946-4 for maximum protection and sterile conditions
Open the catalog to page 4All Normeditec catalogs and technical brochures
-
Mobile operating theatres
4 Pages
-
Tavi instrument table
3 Pages
-
Operating Room Ventilation
16 Pages
-
Ophthalmic Operating Theatre
2 Pages