portable laminar air flow units operating theatre
1 / 37Pages

Catalog excerpts

portable laminar air flow units operating theatre - 1

Focus laminar air flow Focused laminar flow systems: the air is filtered through hepa filters free of microorganisms and then directed immediately onto the surgical instruments and surgical site. It is only then distributed throughout the operating theatre. This protects the critical area of the operating theatre, i.e. the instruments and the surgical site. With this system, the bacterial load on the instruments and surgical site is reduced by more than 95% compared with conventional ventilation systems.

Open the catalog to page 1
portable laminar air flow units operating theatre - 2

Conventional ventilation system Air filtered through conventional ventilation systems is first directed towards the floor and then distributed homogenously throughout the operating theatre. Despite all measure to maintain asepsis, the floor of the operating theatre is always contaminated. Thus bacteria can be transmitted to the patient through the instruments and surgical wound. Conventional ventilation systems cannot ensure a high degree of asepsis in the wound area as the sterile flow is always hindered by surgical lights and medical stuff thus favouring bacteria to wound area. In the...

Open the catalog to page 2
portable laminar air flow units operating theatre - 3

Focus laminar air flow

Open the catalog to page 3
portable laminar air flow units operating theatre - 4

Operating room with laminar air flow The traditional laminar air flow protect the instruments only inside the laminar air flow Most instruments are prepared outside the traditional laminar air flow and thus already being contaminated during the preparation.

Open the catalog to page 4
portable laminar air flow units operating theatre - 5

Mixed ventilation system ZONA PROTETTA The clean “sterile air” is first touching the unsterile floor and then distributed in the O.R. There isn’t any real protected sterile area in the operating room to keep instruments or operating field sterile!

Open the catalog to page 5
portable laminar air flow units operating theatre - 6

The clean “sterile air” is first touching the unsterile floor and then distributed in the O.R. There isn’t any real protected sterile area in the operating room to keep instruments or operating field steri

Open the catalog to page 6
portable laminar air flow units operating theatre - 7

Study: Possible instrument contamination in the operating room during implantation of Knee and Hip Arthroplasty Thieme Verlag 2016)

Open the catalog to page 7
portable laminar air flow units operating theatre - 8

Study: Possible instrument contamination in the operating room during implantation of Knee and Hip Arthroplasty Thieme Verlag 2016)

Open the catalog to page 8
portable laminar air flow units operating theatre - 9

Instrument contamination after 60 minutes (*1,2) Conclusion: Only the instruments prepared inside the laminar air flow or with the focussed laminar air flow shows good aseptic results 1) Possible instrument contamination in the operating room during implantation of knee and hip arthroplasty. Journal for orthopedic and trauma surgery. April 2016, Germany 2) Influence of different ventilations systems upon the contamination of medical devices; Hyg Med 2013; 38 – 4

Open the catalog to page 9
portable laminar air flow units operating theatre - 10

protected zone Enlarge your protected zone with focused laminar air flow

Open the catalog to page 10
portable laminar air flow units operating theatre - 11

protected zone protected zone protected zone protected zone

Open the catalog to page 11
portable laminar air flow units operating theatre - 16

Consumation of antibiotics in Europe consumo per 1000 abitanti e per giorno

Open the catalog to page 16
portable laminar air flow units operating theatre - 17

Klebsiella pneumoniae : percentuale di isolati invasivi resistenti ai carbapenemici wm i 50% No data reported or levs than 10 isolates i—i Notmduded * http://ecd-C.-eur,Qpa.eu/en/healthtopics/antimicrobial resistanc e/database/Pages/database.aspx

Open the catalog to page 17
portable laminar air flow units operating theatre - 18

Escherichia coli: percentuale di isolati invasivi resistenti alla terza generazione di cefalosporina 2010 2014

Open the catalog to page 18
portable laminar air flow units operating theatre - 19

Epidemiological stages of nationwide spread of CPE i i Countries not participating i i No case reported i i Sporadic occurrence l i Single hospital outbreak I I Sporadic hospital outbreaks i I Regional spread Inter-regional spread Endemic situation Non-visible countries Luxembourg Malta

Open the catalog to page 19
portable laminar air flow units operating theatre - 22

Orthopaedic surgery: The focussed oriented laminar air flow can be placed to protect the instruments and the operating field. info@normeditec.com

Open the catalog to page 22
portable laminar air flow units operating theatre - 23

Particle counting after 90 minutes with Toul focus laminar air flow without Toul laminar air flow

Open the catalog to page 23
portable laminar air flow units operating theatre - 24

The helmets protects the operating field but not necessarily the instruments as they are placed outside !

Open the catalog to page 24
portable laminar air flow units operating theatre - 25

Cardiac surgery Florence

Open the catalog to page 25
portable laminar air flow units operating theatre - 26

Transplantation surgery Torino

Open the catalog to page 26
portable laminar air flow units operating theatre - 27

Cardiac surgery San Michele Caserta

Open the catalog to page 27
portable laminar air flow units operating theatre - 28

Cardiac surgery Udine

Open the catalog to page 28
portable laminar air flow units operating theatre - 29

Cardiac surgery Rome Tor Vergate

Open the catalog to page 29
portable laminar air flow units operating theatre - 30

The instruments can be prepared in every place of the operating room under sterile conditions. Afterwards the unit is transported to the operating field protecting both the instruments and the operating field. info@normeditec.com

Open the catalog to page 30
portable laminar air flow units operating theatre - 31

Conventional Ophthalmology room Operio Ophthalmology room The focus laminar air flow keeps the instruments and the operating field extreme sterile as there are no obstacles like surgical lights or operating staff in between info@normeditec.com

Open the catalog to page 31
portable laminar air flow units operating theatre - 32

Intravitreal injections Intravitreal injections should be given in a clean room. Operio provides with very high aseptic conditions. The aseptic conditions achieved with Operio are superior to any operating room due to the fact that the sterile air is immediately directed to the instrument table and operating field in combination with the use of hepa h14 filters . info@normeditec.com

Open the catalog to page 32
portable laminar air flow units operating theatre - 34

Traceability with bar code system even after years!

Open the catalog to page 34
portable laminar air flow units operating theatre - 35

Universita Uppsala Without focussed laminar air flow with focussed Laminar air flow

Open the catalog to page 35
portable laminar air flow units operating theatre - 36

San Martino Genova instrument contamination Riduzione: 100 % Università degli studi di Genova Sossai –Dagnino 2007

Open the catalog to page 36