Prevention and treatment of endophthalmitis following cataract surgery
4Pages

{{requestButtons}}

Catalog excerpts

Prevention and treatment of endophthalmitis following cataract surgery - 1

Prevention and treatment of endophthalmitis following cataract surgery Operio sterile Laminar Air flow unit eliminates over 99.9% of all bacteria’s during surgery also coronavirus SARS-CoV-2) and other microorganisms. Postoperative endophthalmitis is typically caused by the perioperative introduction of microbial organisms during surgery. Operio sterile Air Flow: the device works with high-purifying Hepa H 14 filters which purify the air in the operating room and on the instruments practically completely (99.9%) of bacteria, viruses (also coronavirus SARSCoV-2) and other microorganisms. Eye surgery requires the greatest possible level of asepsis because the consequences of endophthalmitis are serious and often irreversible. The mobility of the Operio devices and the low price makes it possible to upgrade existing and old operating theaters and intervention rooms quickly and inexpensively. In the outpatient area, intravitreal injections, cataract surgeries and other ophthalmological surgeries can be performed under highly aseptic conditions that were previously only possible in a very expensive operating room. Delay in proper treatment can lead to serious blinding complications due to the risk of sub foveal haemorrhage, sub retinal fibrosis, damage to photoreceptors, or vitreous haemorrhage. Operio sterile Air Flow: the devices work with high-purifying Hepa H 14 filters which purify the air in the operating room and on the instruments practically completely (99.9%) of bacteria, viruses (also coronavirus SARS-CoV-2) and other microorganisms . With this principle, an extremely high level of germs can be achieved in the operating theater and on the instruments, which was previously only possible in a very expensive ISO 5 operating rooms. The devices can be positioned in such a way that a “germ-free zone” is set up, which offers the greatest possible protection for both the surgical team and the patient. The devices filter 400 m3 of air per hour so that the microorganisms in the entire room can be reduced. Areas of application: intravitreal injections, cataract surgeries, glaucoma surgeries, refractive surgery, laser surgery, etc. The devices are extremely efficient because they precisely protect the area of the surgical field and instruments recommended by the German Robert Koch Institute from bacteria and microorganisms without obstacles such as surgical microscope or OR light. Furthermore, Operio can increase the personal protection of surgeons and operating room personnel Normeditec (Nordic Medical Technology) Germany Heilbronn Tel.: +49 (0) 7139/ 20 90 85 9 Fax: +49 (0) 7139/ 59 34 98 6 Email: info@normeditec.de www.normeditec.com Italy Parma Tel +39 348 730 24 45 info@normeditec.com

Open the catalog to page 1
Prevention and treatment of endophthalmitis following cataract surgery - 2

Traditional air flow ceilings only work very limited Operio: prepare the instruments protected With Operio, the instruments and implants can always be prepared in the protected area with the sterile Air Flow devices. Then the operating instrument table is simply moved to the operating area and the protection area is then expanded to include the operating area. With conventional supply air ceilings, the protection area of the instruments is only guaranteed within the supply air ceiling - the instruments are almost always unpacked outside the supply air ceiling and the sterility of the...

Open the catalog to page 2
Prevention and treatment of endophthalmitis following cataract surgery - 3

Intravitreal injectiones The sterile OP-Air Flow device Operio enables inexpensive aseptic conditions to be created for operations and intravitreal injections in eye surgery. The devices work with high-purifying Hepa H 14 filters which purify the air in the operating room and on the instruments practically completely (99.995%) of bacteria and other microorganisms. You combine the advantages of outpatient surgery (shorter intervention times, lower costs, better profitability, more patient satisfaction) while maintaining asepsis, which is comparable to a conventional operating room....

Open the catalog to page 3
Prevention and treatment of endophthalmitis following cataract surgery - 4

Technical specifications The Operio devices are extremely small and handy and can also be used in very small rooms. The removable instrument table from Operio is available in various lengths of 45 cm (for intravitreal injections), 60 cm (for ophthalmic operations and intravitreal injections) and 75 cm (for operations that require a lot of instruments). The electrical height adjustment can be carried out by the sterile OR staff (using a sterile covered display) as well as by the other OR staff using a separate display. There is no need to purchase a separate instrument table for storing the...

Open the catalog to page 4