video corpo

renovating and upgrading existing operating rooms
5Pages

{{requestButtons}}

Catalog excerpts

renovating and upgrading existing operating rooms - 1

Renovating Operating Rooms To Meet Modern Hygienic conditions Solutions for handling also low ceiling operating room heights Existing operating rooms can be upgraded to modern hygienic conditions in a few minutes with the mobile laminar air flow system Operio. The affordable focused laminar air flow acts directly on the surgical site and instrument table without being impeded by surgical lights or medical staff, thus reducing by up to 95% the bacterial load on the surgical site and instrument table Mobile Laminar Air Flow Aseptic conditions for implant surgery The sterile mobile laminar air flow system operio provides immediate high aseptic conditions for implant surgery The mobile laminar airflow unit makes it possible to use a laminar air flow also for al kind of implant surgery and ambulatory surgery at an affordable price thus offering good hygienic conditions for existing operating rooms Low operating costs Can be used immediately Affordable price

Open the catalog to page 1
renovating and upgrading existing operating rooms - 2

Focus laminar air flow Conventional ventilation system Bacterial load after 60 min. Bacterial load after 60 min. 0,2- 0,52 CFU/m3 (*1) Focused laminar flow systems: the air is filtered through hepa filters free of microorganisms and then directed immediately onto the surgical instruments and surgical site. It is only then distributed throughout the operating theatre. This protects the critical area of the operating theatre, i.e. the instruments and the surgical site. With this system, the bacterial load on the instruments and surgical site is reduced by more than 95% compared with...

Open the catalog to page 2
renovating and upgrading existing operating rooms - 3

Focus laminar air flow operating room The focus-oriented, mobile laminar air flow devices generate an ultraclean, germ-free air flow by filtering the air with a Hepa H14 filter, which can be aimed precisely at the desired operating field area. The “sterile air flow” is not hindered neither by the operating theater lights nor by the operating theater team. In this way, extremely low-germ air can be created in the area of the operating theater and the instruments, which makes it possible to operate under perfectly hygienic conditions Conventional air flow systems Umbrella effect: the C-arm...

Open the catalog to page 3
renovating and upgrading existing operating rooms - 4

Hand surgery maxillofacial surgery plastic surgery The positioning of the Operio laminar air flow unit is very easy. The sterile Air Flow protects both the instruments and the operating field. An extremely high level of asepsis is achieved, as the sterile air flow is not hindered by the surgical team or by surgical lights. The sterile air flow is perceived by the staff as very pleasant, as it does not generate cold air. Surgery with Covid-19 patients: the devices work with highly cleaning Hepa H 14 filters which also eliminate coronavirus Covid-19 to 99.9%! The devices can be positioned in...

Open the catalog to page 4
renovating and upgrading existing operating rooms - 5

Technical specifications The devices are extremely small and handy and can also be used in very small spaces. The removable instrument table by Operio is available in various lengths of 45 cm (for the smallest operations), 60 cm (for normal operations) and 75 cm (for operations that require a lot of instruments). The electrical height adjustment can be carried out by the sterile OR staff (using a sterile covered display) as well as by the other OR staff using a separate display. There is no need to purchase a separate instrument table for storing the instruments. The constant cleaning of...

Open the catalog to page 5