

Catalog excerpts

North East Monitoring, Inc. advancing Hotter technology™ exceeds accuracy analysis, pattern classifiers provide Hypopnea Index) sleep labs relieve symptoms Integrated, add-on Where would you rather sleep? Let LX® Sleep be the answer to your dreams with in-home, overnight, unattended, multi-parameter, sleep study for detection of OSA (Obstructive Sleep Apnea) This convenient HST (Home Sleep Test) device provides a conforming methodology for multi-parameter, overnight, unattended sleep study that is described in CMA's NCD (National Coverage Decision) CAG- 00093R2. LX® Sleep software applies proprietary algorithms to data collected by NorthEast's OxyHolter to provide a simple alternative to the PSG sleep lab experience to accurately identify OSA (Obstructive Sleep Apnea). LX® Sleep defines epochs of normal versus SDB (Sleep Disordered Breathing). Then it performs pattern recognition on ECG and Sp02 signals; and applies a linear discriminant analysis and an age- based classifier to derive an AHI (Apnea Hypopnea Index). An AHI < 5 represents no clinically significant apnea; 5 <AHI < 15 represents mild apnea; AHI > 15 represents moderate-to-severe apnea.* Current users of Holter LX® Analysis and/or the tried-and-true DR180 Series can easily add the LX® Sleep software option and either an OxyHolter or OxyHolter/A (with airflow) cable, thereby creating the most accurate, easy-to-use OSA detection system on the market today. *As per Decision Memo for Continuous Positive Airway Pressure (CPAP) Therapy for Obstructive Sleep Apnea (OSA) (CAG-00093R2); March 13, 2008 Sleep Apnea Screen for Ambulatory Holter/Oximetry Patient Review HRV 12 Lead Settings Help Bin Critical Events Saved Strips Page Trends Tables Reports Update 09:07:00.Opm-01 Type |ST level | ▼ | Hours |B \^\ |Artifact | Apnea [oil] [off] | Run Analysis] | Desat \pn\[off] |sn02HR 90 Mill 95 Max 95
Open the catalog to page 1
LX ® Sleep Software OxyHolter plus LX® Sleep exceeds accuracy of ECG-only analysis Earlier systems from other vendors only utilized the ECG signal to assess OSA. Combined analysis of ECG and SpO2 yields better correlation with simultaneously collected, full PSG study data. HST method yields more accurate results with a reduced “white coat effect” by sleeping at home rather than in an unfamiliar, lab environment. 90+% sensitivity and specificity for OSA in preliminary studies In the many preliminary studies that compared the diagnostic accuracy for OSA using simultaneously collected data...
Open the catalog to page 2All NorthEast Monitoring catalogs and technical brochures
-
LX Remote
2 Pages
-
DR200/HE
2 Pages
-
DR181
2 Pages
-
Holter LX ®
2 Pages
-
NorthEast Monitoring, Inc
9 Pages
-
DR200/E
2 Pages