  3. Anesthesia Patient Monitor -Gemini

Anesthesia Patient Monitor -Gemini
1 /2Pages

Anesthesia Patient Monitor -Gemini

Anesthesia Patient Monitor -Gemini
1 /2Pages

Catalog excerpts

Anesthesia Patient Monitor -Gemini-1

Technical Specifications Display NIBP Masimo ISA™ Sidestream CO2 (Optional) Parameter Measurement: BC: 0~30(Only limited to the combined use of an external sensor with a BIS module) EMG: 30~55dB(bar chart)with intensity between 30dB and 80dB (tendency chart) BIS: 0~100 SQI: 0%~100% SR: 0%~100% SEF: 0.5Hz~30Hz TP:40~100Db EEG Measurement: Input impedance>5MQ Noise(RTI)<2pV(0.25~50Hz) Input signal range: ±1Mv EEG bandwidth between: 0.25Hz~110Hz GEMINI 15.6717719" TFT Touch screen Resolution: 1366 x 768 Number of traces: 12 waveforms LAN: 1 standard RJ45 port WLAN:IEEE 802.11b/g/n USB: 2 USB connectors SD: 1 SD card socket VGA: 1 VGA monitor connnector Output: 1 connector for Nurse call,Defib Sync Analog Output Lead type :3-lead,5-lead,12-lead ECG waveform:2 channels,7 channels, 12 channels Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (x1.0), 20mm/mV (x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, x0.5, x1, x2 Respiratory impedance range: 0.5-5Q Baseline impedance: 500-4000Q Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s Accuracy:±0.1°C or ±0.2°C °F(without probe) Measurement range: 5~50°C (41~122°F) Channel:Two channels Resolution: 0.1°C Parameters:T1,T2 and TD Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric); ±3%(70-100%, Neonate); 0-69%,unspecified Refreshing Rate: 1s Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric,non-motion, low perfusion); ±3%(70-100%, Neonate,non-motion); ±3%(70-100%, motion); 0-69%,unspecified Refreshing Rate: 1s Range: 35~300 bpm Resolution: 1bpm Accuracy: ±2bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-270 Range of Diastolic pressure: Adult 10-210 Range of Mean pressure: Adult 20-230 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware, double safety protection Cuff pressure range: 0-280mmHg Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Q Method: Thermodilution Range: C.O.: 0.2 to 20 L/min TB: 23 to 45 C T1: -1 to 27°C Accuracy:C.O.:±5% or ±0.1L/min,whichever is greater TB,T1:±0.5°C (without sensor) Measurement range: 0-19.7%,150mmHg, or 0-20kPa Resolution: 0.1mmHg Measurement accuracy 0 - 40 mmHg: ± 2 mmHg 41 - 70 mmHg: ± 5% of reading 71 - 100 mmHg: ± 8% of reading 101 - 150 mmHg: ± 10% of reading Respiration rate: 3-150 bpm Respiration rate accuracy: 1% ±1bpm Warm-up time: 97% within 8s, full accuracy within 20s Measurement rage: 0-20%(0-150mmHg) Accuracy: < 5.0% CO 2: ± 2 mmHg > 5.0% CO 2: < 6% of reading Respiration rate: 2-150 BPM Respiration rate accuracy: 1% ±1BPM Warm-up time: 97% within 45s, full accuracy within 10 min Rise times(t10-90%): About 100ms, when flow is 100 ml/min, adult water trap,1.5m sampling tube Delay time: <3sec when flow is 100 ml/min, adult water trap, 1.5m sampling tube Built-in, Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50ml/min(+/-10/min) Measurement Range: 0 -25% Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Rise time: 200ms,typical at 50ml/min flow rate T ota l res ponse time: within 3 seconds (with 2 m Momoline sampling line) AWR R Ra nge: 0-150bpm AWRR Accuracy:±1 breath Measurement Range: 0 -25% Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Warm-up time: Full accuracy within 10 seconds AWRR Range: 0-150bpm AWRR Accuracy:±1 breath Masimo Multi-gas ISA OR+/IRMA AX+ CO2 (optional) Gas:CO2,N2O,HAL,ISO,ENF,SEV,DES with automatic identification Warm-up time: Full accuracy within 20 seconds for IRMA AX+ CO2 Accuracy: 0-10%:±(0.2%+2% of the reading) 0-15%:±(0.3%+2% of the reading) N2O Accuracy: 0-100%:±(2%+2% of the reading) HAL,ISO,ENF: 0-8%:±(0.15%+5% of the reading) SEV:0-10%: ±(0.15%+5% of the reading) DES:0-22%: ±(0.15%+5% of the reading) Agent identification time:<20s(typical<10s) AWRR range: 0-150bpm AWRR accuracy: +/-1bpm Apnea time: 20~60s Microprocessor-controlled Stimulation Mode: TOF, TOFS, PTC, 1Hz Twitch, 0.1Hz Twitch ,DBS DBS3.3 and 3.2(Double Burst) , Tetanic Stimulation (Burst), 5s - 50Hz or 100Hz Output(accuracy±5% of full scale value) Surface electrodes: Constant current,0-60mA(0-12/18pC) up to 5KOhm. Monophasic, 200ps or 300ps pulse width Needle electrodes: Constant current,0-6mA(0-0.24pC) up to 5KOhm. Monophasic, 40ps pulse width Acceleration transducer: Accuracy±5% of full scale value Temperature sensor: Range 20.0-41.5°C(accuracy±5°C) Power: AC 100-250V, 50/60Hz Temperature: 5-40°C Humidity: <80% Patient Range: Adult, Pediatric, Neonate Add: 4th Floor, Building C, Jin Wei Yuan Industrial Park, Julongshan Area, Kengzi St, Pingshan District, Shenzhen, P.R.China Tel: +86 755 23090266 Fax: +86 755 23010273 Email: [email protected] Website: http://www.northernmeditec.com

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.