Critical Care Patient Monitor - Venus

Critical Care Patient Monitor - Venus

Critical Care Patient Monitor - Venus

Product catalog summary
Technical Specifications
  • Display: 15.6” TFT Touch screen with a resolution of 1366 x 768, capable of displaying 12 waveforms.
  • CO2 Measurement: Optional Masimo IRMATM Mainstream CO2 with a range of 0-25% and accuracy of ±0.2% for 0-15%.
  • Temperature Measurement: Two channels with a range of 0~50℃ and accuracy of ±0.1℃.
  • SpO2 Measurement: Optional Masimo SET® with accuracy of ±2% for adults and pediatrics, ±3% for neonates.
  • NIBP Measurement: Automatic oscillometric method with systolic, diastolic, and mean pressure ranges specified for adults, pediatrics, and neonates.
  • ECG: Supports 3-lead, 5-lead, and 12-lead configurations with various display sensitivities and sweep speeds.
  • IBP: Optional with a range of -50 to 300 mmHg and accuracy of ±2% or ±1mmHg.
  • Recorder: Optional thermal dot array with 3 waveform channels.
  • RESP: Thoracic electrical bioimpedance method with a range of 0-150 bpm.
  • Operation Environment: Power supply of AC 100-250V, 50/60Hz, operating temperature of 5-40℃, and humidity <80%.
Optional Features
  • Masimo Multi-gas ISA AX+: Mainstream CO2 with automatic gas identification.
  • NMT: Neuromuscular monitoring with various stimulation modes.
  • EEG Measurement: Aspect BISx module for monitoring consciousness levels.
  • Central Monitoring System: Supports up to 64 beds with wired or wireless CMS compatibility.
Additional Features
  • Graphical and tabular trend review for 120 hours.
  • 48 hours full disclosure wave review for each patient.
  • Pacemaker detection and ST & arrhythmia analysis.
  • Alarm visibility from 360 degrees.
See more

Catalog excerpts

Critical Care Patient Monitor - Venus-1

Technical SpecificationsDisplay NIBP Masimo ISA™ Sidestream CO2 (Optional) 15.6” TFT Touch screen Resolution: 1366 x 768 Number of traces: 12 waveforms LAN: 1 standard RJ45 port WLAN:IEEE 802.11b/g/n USB: 2 USB connectors VGA/HDMI: 1 VGA/HDMI socket Output: 1 connector for Nurse call, Defib Sync Analog ECG Lead type :3-lead,5-lead,12-lead ECG waveform:2 channels,7 channels, 12 channels Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (x1.0), 20mm/mV (x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV HR range: 15 - 350 bpm Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% RESP Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, x0.5, x1, x2 Respiratory impedance range: 0.5-5Q Respiration range: 0 - 150bpm Baseline impedance: 500-4000Q Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s TEMP Accuracy:±0.1°C or ±0.2°C °F(without probe) Measurement range: 0~50°C (32~122°F) Channel:Two channels Resolution: 0.1°C SpO2 Measurement range : 0-100% PI display Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric); ±3%(70-100%, Neonate); 0-69%,unspecified Refreshing Rate: 1s Masimo SET® SpO2(Optional) Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric,non-motion, low perfusion); ±3%(70-100%, Neonate,non-motion); ±3%(70-100%, motion); 0-69%,unspecified Refreshing Rate: 1s Pulse Rate Range: 30~300 bpm Resolution: 1bpm Accuracy: ±2bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Northern Meditec Limited Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-270 Range of Diastolic pressure: Adult 10-210 Range of Mean pressure: Adult 20-230 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware, double safety protection Cuff pressure range: 0-300mmHg IBP(Optional) Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Q C.O.(Optional) Method: Thermodilution Range: C.O.: 0.2 to 20 L/min TB: 23 to 45 C T1: -1 to 27C Accuracy:C.O.:±5% or ±0.1L/min,whichever is greater TB,T1:±0.5°C (without sensor) Measurement range: 0-19.7%,150mmHg, or 0-20kPa Resolution: 0.1mmHg Measurement accuracy 0 - 40 mmHg: ± 2 mmHg 41 - 70 mmHg: ± 5% of reading 71 - 100 mmHg: ± 8% of reading 101 - 150 mmHg: ± 10% of reading Respiration rate: 3-150 bpm Respiration rate accuracy: 1% ±1bpm Warm-up time: 97% within 8s, full accuracy within 20s Measurement rage: 0-20%(0-150mmHg) Accuracy: < 5.0% CO 2: ± 2 mmHg > 5.0% CO 2: < 6% of reading Respiration rate: 2-150 BPM Respiration rate accuracy: 1% ±1BPM Warm-up time: 97% within 45s, full accuracy within 10 min Rise times(t10-90%): About 100ms, when flow is 100 ml/min, adult water trap,1.5m sampling tube Delay time: <3sec when flow is 100 ml/min, adult water trap, 1.5m sampling tube Recorder (Optional) Built-in, Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50ml/min(+/-10/min) Measurement Range: 0 -25% Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Rise time: 200ms,typical at 50ml/min flow rate Tot al r esponse time: within 3 seconds (with 2 m Momoline sampling line) AWR R Ra nge: 0-150bpm AWRR Accuracy:±1 breath MasfnoIlPIviA™ Mainstream CO2 (Optional) Measurement Range: 0 -25% Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Warm-up time: Full accuracy within 10 seconds AWRR Range: 0-150bpm AWRR Accuracy:±1 breath Masimo Multi-gas ISA AX+Mainstream CO2 (Optional) Gas:CO2,N2O,HAL,ISO,ENF,SEV,DES with automatic identification Warm-up time: Full accuracy within 20 seconds for IRMA AX+ CO2 Accuracy: 0-10%:±(0.2%+2% of the reading) 0-15%:±(0.3%+2% of the reading) N2O Accuracy: 0-100%:±(2%+2% of the reading) HAL,ISO,ENF: 0-8%:±(0.15%+5% of the reading) SEV:0-10%: ±(0.15%+5% of the reading) DES:0-22%: ±(0.15%+5% of the reading) Agent identification time:<20s(typical<10s) AWRR range: 0-150bpm AWRR accuracy: +/-1bpm Apnea time: 20~60s Aspect BISx module(Optional) Parameter Measurement: BC: 0~30(Only limited to the combined use of an external sensor with a BIS module) EMG: 30~55dB(bar chart)with intensity between 30dB and 80dB(tendency chart) BIS: 0~100 SQI: 0%~100% SR: 0%~100% SEF: 0.5Hz~30Hz TP:40~100Db EEG Measurement: Input impedance>5MQ Noise(RTI)<2pV(0.25~50Hz) Input signal range: ±1Mv EEG bandwidth between: 0.25Hz~110Hz Microprocessor-controlled Stimulation Mode: TOF, TOFS, PTC, 1Hz Twitch, 0.1Hz Twitch ,DBS DBS3.3 and 3.2(Double Burst) , Tetanic Stimulation (Burst), 5s - 50Hz or 100Hz Output (accuracy±5% of full scale value) Surface electrodes: Constant current,0-60mA(0-12/18pC) up to 5KOhm. Monophasic, 200ps or 300ps pulse width Needle electrodes: Constant current,0-6mA(0-0.24pC) up to 5KOhm. Monophasic, 40ps pulse width Acceleration transducer: Accuracy±5% of full scale value Temperature sensor: Range 20.0-41.5°C(accuracy±5°C) Operation Environment Power: AC 100-250V, 50/60Hz Temperature: 5-40C Humidity: <80% Patient Range: Adult, Pediatric, Neonate Critical Care Patient Monitor Add: 4th Floor, Building C, Jin Wei Yuan Industrial Park, Julongshan Area, Kengzi St, Pingshan District, Shenzhen, P.R.China Email: [email protected] Website: http://