Multi-parameter Patient Monitor - Taurus
1 /1Page

Multi-parameter Patient Monitor - Taurus

Multi-parameter Patient Monitor - Taurus
1 /1Page

Catalog excerpts

Multi-parameter Patient Monitor - Taurus-1

Various mounting solutions Multi-parameter Patient Monitor Multi-parameter Patient Monitor 12.1”color TFT touch screen,wide and flat screen design, Multiple parameter options satisfy the need for ICU,CCU,NICU. Configuration Masimo/Nellcor SpO2, EtCO2, C.O, 2-IBP, AG, BIS,NMT,Thermal recorder 12.1” color TFT LCD Touch screen 8 waveform display,up to 12-lead ECG analysis Powerful calculation(Hemodynamic,Dose,Oxygenation,Ventilation) Pacemaker detection ST & arrhythmia analysis OxyCRGs BIS module, NMTmodule optional Wired/Wireless CMS, support HL7 protocol to HIS SpO2 pulse-tone modulation (Pitch Tone) MEWS(Modified Early Warning Score) Graphical & tabular trend review( 120 hours) 48h full disclosure wave review for each patient Specifications Display 12.1” color TFT LCD touch Screen,resolution: 800 x 600 8 waveform display,12-leads ECG waveforms display Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-280 Pediatric 40-220 Neonatal 40-135 Range of Diastolic pressure: Adult 10-225 Pediatric 10-160 Neonatal 10-100 Range of Mean pressure: Adult 20-240 Pediatric 20-165 Neonatal 20-110 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Ω Graphical & Tabular Trend LAN: 1 standard RJ45 port WLAN: IEEE802.11b/g/n USB:2 USB connectors Output:1 connector for nurse call,Defib sync analog output HDMI: 1 color HDMI monitor connector(optional) ECG Lead type :3-lead,5-lead,12-lead ECG waveform:2 channels,7 channels, 12 channels Display sensitivity: 2.5mm/mV (×0.25), 5mm/mV (×0.5), 10mm/mV (×1.0), 20mm/mV (×2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MΩ Electrode polarization voltage range: ±400mV HR range: 15 - 350 bpm ST Measurement Range: -1.0 - +10 mv Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% SpO2 (Chinese brand ) Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric); ±3%(70-100%, Neonate); 0-69%,unspecified Refreshing Rate: 1s Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric,non-motion,low perfusion); ±3%(70-100%, Neonate,non-motion); ±3%(70-100%, motion); 0-69%,unspecified Refreshing Rate: 1s Method:Trans-thoracic impedance Operation modes: Auto/Manual Measurement range: Adult:0~120 bmp; Neonate/Pediatric:0~150bpm Resolution: 1 bpm Apnea alarm delay:10s,15s,20s,25s,30s,35s,40s Apnea alarm: Selectable Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s Method: Thermodilution Range: C.O.: 0.2 to 20 L/min TB: 23 to 45 ℃ T1: -1 to 27℃ Accuracy:C.O.:±5% or ±0.1L/min,whichever is greater TB,T1:±0.5℃ (without sensor) Accuracy: ±0.1℃ or ±0.2℃ °F(without probe) Measurement range: 0~50℃ Channel:Two channels Resolution: 0.1℃ Parameters:T1,T2 and TD Pulse Rate Range: 30~300 bpm Resolution: 1bpm Accuracy: ±3bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Recorder(optional) Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Masimo ISATM Sidestream CO2 (optional) Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50ml/min(+/-10/min) Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Measurement Range: 0 -25% Rise time: 200ms,typical at 50ml/min flow rate Total response time: within 3 seconds(with 2m Momoline sampling line) AWRR Range: 0~150bpm Masimo IRMATM Mainstream CO2 (optional) Measurement Range: 0 -25% Warm-up time: Full accuracy within 10 seconds Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified AWRR Range: 0-150bpm Masimo Multi-gas ISA OR+/IRMA AX+ CO2 (optional) Gas:CO2,N2O,HAL,ISO,ENF,SEV,DES with automatic identification Warm-up time: Full accuracy within 20 seconds for IRMA AX+ CO2 Accuracy: 0-10%:±(0.2%+2% of the reading) 0-15%:±(0.3%+2% of the reading) N2O Accuracy:0-100%:±(2%+2% of the reading) HAL,ISO,ENF:0-8%:±(0.15%+5% of the reading) SEV:0-10%:±(0.15%+5% of the reading) DES:0-22%:±(0.15%+5% of the reading) Agent identification time:<20s(typical<10s) AWRR range:0-150bpm AWRR accuracy:+/-1bpm Apnea time:20-60s Operation Environment Power: Temperatu

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.