Multi-parameter Patient Monitor - Taurus
1 / 1Pages

Catalog excerpts

Multi-parameter Patient Monitor - Taurus - 1

Various mounting solutions Multi-parameter Patient Monitor Multi-parameter Patient Monitor 12.1”color TFT touch screen,wide and flat screen design, Multiple parameter options satisfy the need for ICU,CCU,NICU. Configuration Masimo/Nellcor SpO2, EtCO2, C.O, 2-IBP, AG, BIS,NMT,Thermal recorder 12.1” color TFT LCD Touch screen 8 waveform display,up to 12-lead ECG analysis Powerful calculation(Hemodynamic,Dose,Oxygenation,Ventilation) Pacemaker detection ST & arrhythmia analysis OxyCRGs BIS module, NMTmodule optional Wired/Wireless CMS, support HL7 protocol to HIS SpO2 pulse-tone modulation (Pitch Tone) MEWS(Modified Early Warning Score) Graphical & tabular trend review( 120 hours) 48h full disclosure wave review for each patient Specifications Display 12.1” color TFT LCD touch Screen,resolution: 800 x 600 8 waveform display,12-leads ECG waveforms display Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-280 Pediatric 40-220 Neonatal 40-135 Range of Diastolic pressure: Adult 10-225 Pediatric 10-160 Neonatal 10-100 Range of Mean pressure: Adult 20-240 Pediatric 20-165 Neonatal 20-110 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Ω Graphical & Tabular Trend LAN: 1 standard RJ45 port WLAN: IEEE802.11b/g/n USB:2 USB connectors Output:1 connector for nurse call,Defib sync analog output HDMI: 1 color HDMI monitor connector(optional) ECG Lead type :3-lead,5-lead,12-lead ECG waveform:2 channels,7 channels, 12 channels Display sensitivity: 2.5mm/mV (×0.25), 5mm/mV (×0.5), 10mm/mV (×1.0), 20mm/mV (×2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MΩ Electrode polarization voltage range: ±400mV HR range: 15 - 350 bpm ST Measurement Range: -1.0 - +10 mv Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% SpO2 (Chinese brand ) Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric); ±3%(70-100%, Neonate); 0-69%,unspecified Refreshing Rate: 1s Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric,non-motion,low perfusion); ±3%(70-100%, Neonate,non-motion); ±3%(70-100%, motion); 0-69%,unspecified Refreshing Rate: 1s Method:Trans-thoracic impedance Operation modes: Auto/Manual Measurement range: Adult:0~120 bmp; Neonate/Pediatric:0~150bpm Resolution: 1 bpm Apnea alarm delay:10s,15s,20s,25s,30s,35s,40s Apnea alarm: Selectable Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s Method: Thermodilution Range: C.O.: 0.2 to 20 L/min TB: 23 to 45 ℃ T1: -1 to 27℃ Accuracy:C.O.:±5% or ±0.1L/min,whichever is greater TB,T1:±0.5℃ (without sensor) Accuracy: ±0.1℃ or ±0.2℃ °F(without probe) Measurement range: 0~50℃ Channel:Two channels Resolution: 0.1℃ Parameters:T1,T2 and TD Pulse Rate Range: 30~300 bpm Resolution: 1bpm Accuracy: ±3bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Recorder(optional) Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Masimo ISATM Sidestream CO2 (optional) Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50ml/min(+/-10/min) Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Measurement Range: 0 -25% Rise time: 200ms,typical at 50ml/min flow rate Total response time: within 3 seconds(with 2m Momoline sampling line) AWRR Range: 0~150bpm Masimo IRMATM Mainstream CO2 (optional) Measurement Range: 0 -25% Warm-up time: Full accuracy within 10 seconds Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified AWRR Range: 0-150bpm Masimo Multi-gas ISA OR+/IRMA AX+ CO2 (optional) Gas:CO2,N2O,HAL,ISO,ENF,SEV,DES with automatic identification Warm-up time: Full accuracy within 20 seconds for IRMA AX+ CO2 Accuracy: 0-10%:±(0.2%+2% of the reading) 0-15%:±(0.3%+2% of the reading) N2O Accuracy:0-100%:±(2%+2% of the reading) HAL,ISO,ENF:0-8%:±(0.15%+5% of the reading) SEV:0-10%:±(0.15%+5% of the reading) DES:0-22%:±(0.15%+5% of the reading) Agent identification time:<20s(typical<10s) AWRR range:0-150bpm AWRR accuracy:+/-1bpm Apnea time:20-60s Operation Environment Power: Temperatu

Open the catalog to page 1

All Northern Meditec catalogs and technical brochures

  1. Crius HF3

    1 Pages