Multi-Parameter Veterinary Monitor -Virgo Vet
1 / 1Pages

Catalog excerpts

Multi-Parameter Veterinary Monitor -Virgo Vet - 1

12.1"color TFT screen,wide and flat screen design Virgo VetMulti-Parameter Veterinary Monitor I Virgo Vet | Multi-Parameter Veterinary Monitor Display NIBP 12.1" color TFT LCD resolution: 800 x 600 8 waveform display,12-leads ECG display LAN: 1 standard RJ45 port WLAN: IEEE802.11b/g/n USB:2 USB connectors SD: 1 SD card socket Output:1 connector for nurse call,Defib sync analog output VGA: 1 color VGA monitor connector(optional) Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean ECG Lead type :3-lead,5-lead,12-lead ECG waveform:2 channels,7 channels, 12 channels Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (x1.0), 20mm/mV (x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% Measurement range (mmHg) Range of Systolic pressure: Dog 40-270 Range of Diastolic pressure: Dog 10-210 Range of Mean pressure: Cat 20-230 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg Recorder(optional) SpO2 (Northern ) Measurement range : 0-100% Resolution: 1% Accuracy: ±2%( 70-100%, Cat/Dog); ±3% ( 70-100%, Others); 0-69%,unspecified Refreshing Rate: 1s TEMP IBP(optional) Accuracy: ±0.1°C or ±0.2°C °F(without probe) Measurement range: 5~50°C(41~122°F) Channel:Two channels Resolution: 0.1C Parameters:T1,T2 and TD RESP Method:Trans-thoracic impedance Operation modes: Auto/Manual Measurement range: Adult:0~120 bmp; Neonate/Pediatric:0~150bpm Apnea alarm delay:10s,15s,20s,25s,30s,35s,40s Apnea alarm: Selectable Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Q Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolutions dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Operation Environment Power: Temperature: Humidity: Patient Range: Pulse Rate Range: 30~254 bpm Resolution: 1bpm Accuracy: ±3bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Optional Northern Meditec Limited Masimo SpO2, , Thermal recorder, touch screen Add: Room 420, Fourth Floor, Block B-1, Famous Industrial Products Exhibition & Purchasing Center, No.168 Baoyuan Road, Xixiang, Bao'an District, Shenzhen 518102, P.R.China Email: info@northernmeditec.com Website: http://www.northernmeditec.com

Open the catalog to page 1

All Northern Meditec catalogs and technical brochures

  1. Crius HF3

    1 Pages