1. Catalogs
  2. Northern Meditec
  3. Multi-Parameter Veterinary Monitor -Virgo Vet

Multi-Parameter Veterinary Monitor -Virgo Vet
1 /1Page

Multi-Parameter Veterinary Monitor -Virgo Vet

Multi-Parameter Veterinary Monitor -Virgo Vet
1 /1Page

Catalog excerpts

Multi-Parameter Veterinary Monitor -Virgo Vet-1

12.1"color TFT screen,wide and flat screen design Virgo VetMulti-Parameter Veterinary Monitor I Virgo Vet | Multi-Parameter Veterinary Monitor Display NIBP 12.1" color TFT LCD resolution: 800 x 600 8 waveform display,12-leads ECG display LAN: 1 standard RJ45 port WLAN: IEEE802.11b/g/n USB:2 USB connectors SD: 1 SD card socket Output:1 connector for nurse call,Defib sync analog output VGA: 1 color VGA monitor connector(optional) Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean ECG Lead type :3-lead,5-lead,12-lead ECG waveform:2 channels,7 channels, 12 channels Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (x1.0), 20mm/mV (x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% Measurement range (mmHg) Range of Systolic pressure: Dog 40-270 Range of Diastolic pressure: Dog 10-210 Range of Mean pressure: Cat 20-230 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg Recorder(optional) SpO2 (Northern ) Measurement range : 0-100% Resolution: 1% Accuracy: ±2%( 70-100%, Cat/Dog); ±3% ( 70-100%, Others); 0-69%,unspecified Refreshing Rate: 1s TEMP IBP(optional) Accuracy: ±0.1°C or ±0.2°C °F(without probe) Measurement range: 5~50°C(41~122°F) Channel:Two channels Resolution: 0.1C Parameters:T1,T2 and TD RESP Method:Trans-thoracic impedance Operation modes: Auto/Manual Measurement range: Adult:0~120 bmp; Neonate/Pediatric:0~150bpm Apnea alarm delay:10s,15s,20s,25s,30s,35s,40s Apnea alarm: Selectable Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Q Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolutions dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Operation Environment Power: Temperature: Humidity: Patient Range: Pulse Rate Range: 30~254 bpm Resolution: 1bpm Accuracy: ±3bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Optional Northern Meditec Limited Masimo SpO2, , Thermal recorder, touch screen Add: Room 420, Fourth Floor, Block B-1, Famous Industrial Products Exhibition & Purchasing Center, No.168 Baoyuan Road, Xixiang, Bao'an District, Shenzhen 518102, P.R.China Email: [email protected] Website: http://www.northernmeditec.com

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.