Patient Monitor -Virgo
1Pages

{{requestButtons}}

Catalog excerpts

Patient Monitor -Virgo - 1

Patient Monitor 12.1"color TFT LCD screen,wide and flat screen design,ecnomic and reliable Configuration Optional ECG + SpO2+NIBP+2TEMP+PR+RESP, Li-ion battery Masimo SpO2, IBP, CO2, Thermal recorder, Touch screen, CMS 12.1" color TFT LCD screen 8 waveform display,up to 12-lead ECG analysis Powerful calculation(Hemodynamic,Dose,Oxygenation,Ventilation) Pacemaker detection ST & arrhythmia analysis Various mounting solutions Wired/Wireless CMS, support HL7 protocol to HIS SpO2 pulse-tone modulation (Pitch Tone) MEWS(Modified Early Warning Score) Graphical & tabular trend review( 120 hours) OxyCRGs screen * Night mode, standby mode, venipucture mode Rechargeable Lithium-Ion Battery 48 Hours full disclosure waveforms display Graphical & Tabular Trend Display TEMP Masimo SET® SpO2(Optional) 12.1" TFT LCD screen Resolution: 800 x 600 Number of traces: 8 waveforms ECG Accuracy:±0.1°C or ±0.2°C °F Measurement range: 5~50°C (41~122°F) Channel:Two channels Resolution: 0.1°C Parameters:T1,T2 and TD Lead type :3-lead,5-lead,12-lead ECG waveform:2 channels,7 channels, 12 channels Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (x1.0), 20mm/mV (x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>106 dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV HR range: 15 - 350 bpm Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% RESP Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, x0.5', x1, x2 Measurement range: 3~150 rpm Bandwidth: 0.3 to 2 Hz Respiratory impedance range: 0.5-5Q Baseline impedance: 500-4000Q Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s and 50mm/s Pulse Rate Range: 30~254 bpm Resolution: 1bpm Accuracy: ±2bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Northern Meditec Limited NIBP Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Adult 40-270 Range of Diastolic pressure: Adult 10-210 Range of Mean pressure: Adult 20-230 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware, double safety protection Cuff pressure range: 0-280mmHg Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric,non-motion, low perfusion); ±3% (70-100%, Neonate,non-motion); ±3% (70-100%, motion); 0-69%,unspecified Refreshing Rate: 1s Channel:2-channel or 4-channel ART: 0 to 300 mmHg PA: -6 to 120 mmHg CVP/RAP/LAP/ICP : -10 to 40 mmHg Measurement range: P1/P2 -50 to 300 mmHg Resolution:1mmHg Accuracy: ±2% or ±1mmHg, whichever is greater(without sensor) Sensitivity: 5uV/mmHg/V Impedance range: 300 to 3000Q Recorder (Optional) Built-in, Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Operation Environment SpO2 Measurement range : 0-100% Resolution: 1% Perfusion index display Accuracy: ±2%(70-100%, Adult/Pediatric); ±3% (70-100%, Neonate); 0-69%,unspecified Refreshing Rate: 1s Power: AC 100-250V, 50/60Hz Temperature: 5-40C Humidity: <80% Patient Range: Adult, Pediatric, Neonate Add: 4th Floor, Building C, Jin Wei Yuan Industrial Park, Julongshan Area, Kengzi St, Pingshan District, Shenzhen, P.R.China Tel: +86 755 23090266 Fax: +86 755 23010273 Email: info@northernmeditec.com Website: http://www.northernmeditec.com

Open the catalog to page 1

All Northern Meditec catalogs and technical brochures

  1. Crius HF3

    1 Pages