Veterinary Monitor -Aquarius-Vet
1 / 1Pages

Catalog excerpts

Veterinary Monitor -Aquarius-Vet - 1

Aquarius-VetVeterinary Monitor Configuration Optional SpO2 + NIBP, Li-ion battery Masimo/Nellcor SpO2,Quick Temp,Bar code scanner,wired/wireless CMS • 8" color TFT LCD Screen (Touch screen is an optional) Portable,Lighter weight and sturdy design • Flexible parameters configuration for different clinical environments • Rechargeable Li-ion Battery(up to 12 hours uninterruptable work) Big font and color font display setting Spot-check and continuous monitoring mode • Selectable for Dog, Cat and other animals • Wired/Wireless CMS, support HL7 protocol to HIS Barcode scanner support Thermal recorder support • Graphical & tabular trend review • 48h full disclosure wave review for each animal(stroed in SD card) SpO2+NIBP+ECG+TEMP, Li-ion battery Masimo/Nellcor SpO2,EtCO2,Quick Temp,Bar code scanner,Thermal Recorder,wired/wireless CMS Specifications Display NIBP Infrared Ear Thermometer(optional) 8" color TFT LCD Screen,resolution: 600 x 800 ECG Lead type 3-lead:I, II, III 5-lead:I, II, III,aVR, aVL, aVF, V Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (xl.0), 20mm/mV (x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Displayed range: 34~42.20C (93.2~108 F°) Operation ambient temperature range: 10~40°C (50~104°F) Accuracy for displayed temerature range: >35°C (95.9°F)~<42.20C (107.6°F) range ±0.2C (0.4°F) < 350C (95.9°F)~>34°C (93.2°F) range ±0.3C (0.5°F) Measurement range (mmHg) Range of Systolic pressure: Dog 40-270 Range of Diastolic pressure: Dog 10-210 Range of Mean pressure: Dog 20-230 Measurement accuracy Maximum average error: ±5mmHg Phasein IRMATM Sidestream CO2 (optional) Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50ml/min(+/-10/min) Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Measurement Range: 0 -25% Rise time: 200ms,typical at 50ml/min flow rate Total response time: within 3 seconds(with 2m Momoline sampling line) AWRR Range: 0~150bpm Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg Phasein IRMATM Mainstream CO2 (optional) Measurement Range: 0 -25% Warm-up time: Full accuracy within 10 seconds Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified AWRR Range: 0-150bpm RESP Northern SpO2 Touch Screen (Optional) Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, x0.5, x1, x2 Respiratory impedance range: 0.5-5Q Baseline impedance: 500-4000Q Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Cat/Dog); ±3% (70-100%); 0-69%,unspecified Refreshing Rate: 1s Masimo SpO2 (optional) TEMP Operation Environment Portable Design Measurement method: Thermistor Measuring range: 5~50°C (41~122°F) Resolution: 0.1°C Measurement accuracy: ±0.1°C Recorder(optional) Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%,non-motion,low prefusion); ±3% (70-100%, non-motion); ±3% (70-100%, motion); 0-69%,unspecified Refreshing Rate: 1s Quick Temp (Infrared Ear Thermometer) — 120 • / FI Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Pulse Rate Range: 30~254 bpm Resolution: 1bpm Accuracy: ±2bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Hours long trend Northern Meditec Limited 60 Mins short trend Northern Meditec Limited Add: 4th Floor, Building C, Jin Wei Yuan Industrial Park, Julongshan Area, Kengzi St, Pingshan District, Shenzhen City, P.R.China Tel: +86 755 29970566 Fax: +86 755 86528647 Email: info@northernmeditec.com Website: http://www.northernmeditec.com

Open the catalog to page 1

All Northern Meditec catalogs and technical brochures

  1. Crius HF3

    1 Pages