1. Catalogs
  2. Northern Meditec
  3. Veterinary Monitor -Aquarius-Vet

Veterinary Monitor -Aquarius-Vet
1 /1Page

Veterinary Monitor -Aquarius-Vet

Veterinary Monitor -Aquarius-Vet
1 /1Page

Catalog excerpts

Veterinary Monitor -Aquarius-Vet-1

Aquarius-VetVeterinary Monitor Configuration Optional SpO2 + NIBP, Li-ion battery Masimo/Nellcor SpO2,Quick Temp,Bar code scanner,wired/wireless CMS • 8" color TFT LCD Screen (Touch screen is an optional) Portable,Lighter weight and sturdy design • Flexible parameters configuration for different clinical environments • Rechargeable Li-ion Battery(up to 12 hours uninterruptable work) Big font and color font display setting Spot-check and continuous monitoring mode • Selectable for Dog, Cat and other animals • Wired/Wireless CMS, support HL7 protocol to HIS Barcode scanner support Thermal recorder support • Graphical & tabular trend review • 48h full disclosure wave review for each animal(stroed in SD card) SpO2+NIBP+ECG+TEMP, Li-ion battery Masimo/Nellcor SpO2,EtCO2,Quick Temp,Bar code scanner,Thermal Recorder,wired/wireless CMS Specifications Display NIBP Infrared Ear Thermometer(optional) 8" color TFT LCD Screen,resolution: 600 x 800 ECG Lead type 3-lead:I, II, III 5-lead:I, II, III,aVR, aVL, aVF, V Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (xl.0), 20mm/mV (x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Displayed range: 34~42.20C (93.2~108 F°) Operation ambient temperature range: 10~40°C (50~104°F) Accuracy for displayed temerature range: >35°C (95.9°F)~<42.20C (107.6°F) range ±0.2C (0.4°F) < 350C (95.9°F)~>34°C (93.2°F) range ±0.3C (0.5°F) Measurement range (mmHg) Range of Systolic pressure: Dog 40-270 Range of Diastolic pressure: Dog 10-210 Range of Mean pressure: Dog 20-230 Measurement accuracy Maximum average error: ±5mmHg Phasein IRMATM Sidestream CO2 (optional) Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50ml/min(+/-10/min) Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Measurement Range: 0 -25% Rise time: 200ms,typical at 50ml/min flow rate Total response time: within 3 seconds(with 2m Momoline sampling line) AWRR Range: 0~150bpm Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double safety protection Cuff pressure range: 0-280mmHg Phasein IRMATM Mainstream CO2 (optional) Measurement Range: 0 -25% Warm-up time: Full accuracy within 10 seconds Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified AWRR Range: 0-150bpm RESP Northern SpO2 Touch Screen (Optional) Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, x0.5, x1, x2 Respiratory impedance range: 0.5-5Q Baseline impedance: 500-4000Q Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Cat/Dog); ±3% (70-100%); 0-69%,unspecified Refreshing Rate: 1s Masimo SpO2 (optional) TEMP Operation Environment Portable Design Measurement method: Thermistor Measuring range: 5~50°C (41~122°F) Resolution: 0.1°C Measurement accuracy: ±0.1°C Recorder(optional) Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%,non-motion,low prefusion); ±3% (70-100%, non-motion); ±3% (70-100%, motion); 0-69%,unspecified Refreshing Rate: 1s Quick Temp (Infrared Ear Thermometer) — 120 • / FI Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 Pulse Rate Range: 30~254 bpm Resolution: 1bpm Accuracy: ±2bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Hours long trend Northern Meditec Limited 60 Mins short trend Northern Meditec Limited Add: 4th Floor, Building C, Jin Wei Yuan Industrial Park, Julongshan Area, Kengzi St, Pingshan District, Shenzhen City, P.R.China Tel: +86 755 29970566 Fax: +86 755 86528647 Email: [email protected] Website: http://www.northernmeditec.com

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.