1. Catalogs
  2. Northern Meditec
  3. Vital Sign Monitor -Aquarius

Vital Sign Monitor -Aquarius
1 /1Page

Vital Sign Monitor -Aquarius

Vital Sign Monitor -Aquarius
1 /1Page

Catalog excerpts

Vital Sign Monitor -Aquarius-1

AquariusVital Sign Monitor Committed tt Exctleice For Out-Patient Department, Spot-check,Transport,Ward and other basic monitoring Configuration Optional SpO2 + NIBP, Li-ion battery Masimo/Nellcor SpO2,Quick Temp,Bar code scanner,wired/wireless CMS 8.4" color TFT LCD Screen (Touch screen optional) Portable,Lighter weight and sturdy design MEWS (Modified Early Warning Score) Calculations:Hemodynamics/Dose calculation Rechargeable Li-ion Battery(up to 15 hours uninterruptable work) Spot-check and continuous monitoring mode Suitable for Adult, Pediatric and Neonatal Wired/WIFI/3G/4G CMS, support HL7 protocol to HIS Barcode scanner, Infrared ear/Forehead thermometer Night mode selectable, reduce light stimulation and noise Graphical & tabular trend review (240 hours) 48H full disclosure wave review for each patient Masimo/Nellcor SpO2,EtCO2,Quick Temp,Bar code scanner,Thermal Recorder,wired/wireless CMS Physical Specification Display: 8.4" TFT LCD screen Resolution: 600 x 800 Number of traces: 3, up to 7 ECG waveforms Dimension: 175x275xl75mm(WxHxD) Weight: < 2.5 kg under standard configuration LAN: 1 standard RJ45 port WLAN: IEEE 802.11b/g/n USB: 2 USB interface Portable Design Touch Screen (Optional) Lead type 3-lead:I, II, III 5-lead:I, II, III,aVR, aVL, aVF, V ECG waveform: 1 channel, 7 channels Display sensitivity: 2.5mm/mV (x0.25), 5mm/mV (x0.5), 10mm/mV (x1.0), 20mm/mV (x2.0) Wave sweep speed: 3.125mm/s, 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance>5MQ Electrode polarization voltage range: ±400mV HR range: 15 - 350 bpm Baseline recovery time<3s after defibrillation (in monitor and surgery mode) Calibration signal:1mV (peak - peak), accuracy ±3% Measurement method : Automatic oscillometric method Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg) Range of Systolic pressure: Adult Pediatric Neonatal Range of Diastolic pressure: Adult Pediatric Neonatal Range of Mean pressure: Adult Pediatric Neonatal Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1mmHg Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware, double safety protection Cuff pressure range: 0-300mmHg Displayed range: 34~42.20C (93.2~108 F°) Operation ambient temperature range: 10~40C (50~104°F) Accuracy for displayed temerature range: >35°C (95.9°F)~<42.2°C (107.6°F) range ±0.2C (0.4°F) < 350C (95.9°F)~>34C (93.2°F) range ±0.3C (0.5°F) Masimo IRMATM Sidestream CO2 (optional) Warm-up time: Full accuracy within 10 seconds Sampling flow rate: 50ml/min(+/-10/min) Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified Measurement Range: 0 -25% Rise time: 200ms,typical at 50ml/min flow rate Total response time: within 3 seconds(with 2m Momoline sampling line) AWRR Range: 0~150bpm Masimo IRMA™ Mainstream CO2 (optional) Measurement Range: 0 -25% Warm-up time: Full accuracy within 10 seconds Accuracy: 0~15% (±0.2% of the reading) 15~25%, unspecified AWRR Range: 0-150bpm Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, x0.5, x1, x2 Respiratory impedance range: 0.5-5Q 0 - 150bpm Baseline impedance: 500-4000Q Gain: 10 grades Measurement range : 0-100% Parameter monitoring: Perfusion Index(PI) :1-10 Optional Pleth Variability Index(PVI) Resolution: 1% Accuracy: ±2% or ±2bpm Refreshing Rate: 1s Measurement range : 0-100% Resolution: 1% Accuracy: ±2%(70-100%, Adult/Pediatric,non-motion,low perfusion); ±3% (70-100%, Neonate,non-motion); ±3% (70-100%, motion); 0-69%,unspecified Built-in,Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:12.5mm/s, 25 mm/s, 50 mm/s Number of waveform channels:3 Operation Environment Input Power: Temperature: Humidity: Patient Range: Range: 30~300 bpm Resolution: 1bpm Accuracy: ±2bpm (non-motion) ±5bpm (motion) Refreshing rate: 1s Measuring range: 5~50°C (41~122°F) Resolution: 0.1°C Measurement accuracy: ±0.1°C Northern Meditec Limited ftRnORTHERn MEDITEC Northern Meditec Limited Add: 4th Floor, Building C, Jin Wei Yuan Industrial Park, Julongshan Area, Kengzi St, Pingshan District, Shenzhen, P.R.China Tel: +86 755 27952733 Fax: +86 755 23010273 Email: [email protected] Website: http://www.northernmeditec.com C€ 0123 Version: 2.0.1 Issue date: 2019/7/30

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.