StatMaxx R/S/M Electronic humidity and temperature measurement instrument with UMB data logger interface General information Never before, the relative humidity and temperature measurement was as easy. The StatMaxx combines the function of a 2-point control of humdity and temperature with a big LCDisplay and the possibility of data logging by a local data logger unit. Thanks to a direct network connection, the data analysis and visualisation is made directly on a personal computer. The integrated galvanic isolated relay outputs permit also simple control functions. Therewith cooling and heating devices can be easily controlled. The StatMaxx is availabe in 3 versions, S (room), R (duct) and M (remote sensor with 3m cable). 35 ^Z^95 The implemented digital Bus-System (UMB protocol) allows the connection of up 30 ^Z^86 to 4 additional StatMaxx devices to a Data Log 30 data logger (available as well from Novasina) and hence a construction of simple and efficient systems for room monitoring. The humidity sensor is based on a state-of-the-art capacitive technology. Due to miniaturisation and ideal material selection this measurement device offers a high resistance against aggressive substances in the ambient air. The StatMaxx offers also various functions and setting capabilities. With the 3 buttons and the intuitive menu structure it can be configured easily and if required calibrated at 3 humidity points and 1 temperature point. StatMaxx, Novasina's latest quality product „Made in Switzerland". Advantages Applications Versions StatMaxx S : Humidity-temperature instrument for measurement of climatic parameters in rooms (fresh air) with integrated digital sensor and 2-point control capability by configuration of setpoint, hystersis and delay. 0 StatMaxx R : Humidity-temperature instrument for measurement of climatic parameters in ducts (fresh air) with integrated 5 -digital sensor and 2-point control capability by configuration of setpoint, hystersis and delay. -10 _ StatMaxx M : Humidity-temperature instrument for measurement of climatic parameters (fresh air) with remote sensor (3m cable), integrated digital sensor and 2-point -15 -control capability by configuration of setpoint, hystersis and delay. °C -20“ Best price efficiency High accuracy and reproducibility Robust design of sensor and housing Big, clear LC-Display RH / temperature /alarm Simple humidity (3 points), temperature (1 point) calibration Configuration of threshold, hystersis and delay for contact relay Intuitive menu structure Password protection system Versatile utilisation and easy mounting and start-up Mesurement and monitoring of HVAC plants in following applications: • Industrial climatic installations • Anti-freeze protection in rooms • Protection against molds in cellars and archives • Alarming in case of condensation • Monitoring of storages and archives • Long term monitoring in laboratories, production rooms • De-humidification in museums and storages
Open the catalog to page 1Accessories + Spare parts Article no. Spare sensor for room version 75mm 252 3131 Spare sensor for duct version 250mm 252 3132 Spare remote sensor 250mm / 3m cable 252 3133 Wall mounting clip 252 4468 Power supply/contactor for StatMaxx Stat-PU 260 0877 Power supply monitoring StatMaxx Log-PU 260 0869 Humidity Check SAL-SC 11% RH 111 0885 Humidity Check SAL-SC 33% RH 111 0855 Humidity Check SAL-SC 58% RH 260 0219 Humidity Check SAL-SC 75% RH 111 0859 Humidity Check SAL-SC 90% RH 111 0896 Subject to change without notice! Novasina...
Open the catalog to page 21 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
6 Pages
2 Pages
2 Pages
2 Pages
2 Pages