Product catalog summary
Overview: This document provides detailed specifications and product codes for dental abutments and components used in prosthetic and implant procedures. It includes information on screw types, abutment dimensions, fastening torques, and product codes for different configurations.
Specifications: Abutments are listed for single-unit prostheses and multi-unit fixed partial restorations, specifying hex and non-hex configurations with fastening torques of 20Ncm for narrow and 30Ncm for regular abutments. The hex driver size is 1.2mm.
Product Codes and Dimensions: A comprehensive list of product codes is provided for various abutment types, detailing fixture diameters, gingival heights, and angles for each product.
Procedures and Recommendations: The document outlines the use of abutments for removable over-dentures and recommends using impression copings with custom trays, emphasizing the importance of appropriate abutments and analogs for lab procedures.
Digital Technology and Innovation: Highlights include the development of digital solutions for dental restoration, implant, and orthodontics, with benefits such as reduced operation time and improved patient comfort through intraoral scanners.
Key Features: Features include cloud storage for data, color scanning, and built-in anti-fog functions in scanning equipment, emphasizing the role of digital technology in improving dental procedure accuracy and efficiency.
Surgical and Prosthetic Tools: The document lists surgical and prosthetic tools used in dental implant procedures, including drills, drivers, and abutments with detailed specifications, codes, and dimensions.
Sections:
  • Drills: Various types of drills are listed, including final, point, guide, and tapered drills, each with specific codes and dimensions.
  • Fixture Drivers: Categorized as narrow or regular, with specific codes for manual and handpiece operations.
  • Surgical Kits: The NTA Surgical Kit includes protocols for different drill types and recommended RPMs for various bone types.
  • Prosthetic Planning Kits: Include angled abutments with specific codes, diameters, and angles for prosthetic planning and cemented abutments.
  • Additional Tools: Lists torque ratchets, screwdrivers, and adapters with specific codes and intended uses.
Key Specifications:
  • Drill Dimensions: Specified by diameter and length, ranging from Ø1.5 to Ø6.0 with lengths from 6.5mm to 13mm.
  • Abutment Angles: Available in angles of 7°, 15°, and 25°.
  • Prosthetic Flexibility: Emphasizes the ease of use and restorative flexibility of the multi-abutment system.
Recommendations: Suggests specific RPM settings for different drill types and bone densities to ensure optimal performance during surgical procedures.
Contact Information: Provides contact details for Pilatus Swiss Dental GMBH and NTA Implant Ltd., including addresses, phone numbers, and websites.
See more

Catalog excerpts

NTA Catalog-1

You can access all information by scanning the QR code below with your Smartphone / Tablet

 Open the catalog to page 1
NTA Catalog-2

“To improve is to change; to be perfect is to change often” Winston Churchi

 Open the catalog to page 2
NTA Catalog-3

Nta Implant Company Group Our company is engaged in providing solutions in implant dentistry by offering highest quality of dental implants. Development, manufacturing process, marketing, publicity, and trademark rights of all the products are legal and belong to our company. The products are being developed using state of the art technologies under the light of the up-to-date scientific data in the field of implantology. We manufacture “Screw-type” and “Press-fit” implants with their accessories under the brands of Nta Implant, Nta Shorter Implant, Nta Shorter Plus Implant and Hybrid Implant....

 Open the catalog to page 3
NTA Catalog-4

DIAMETER LENGHT Conical Connection With Hex Conical connection provides bacterial seal and prevents microleackage issues at implant-abutment interface. Internal hex index ensures proper and easy seating of the abutment. Platform Design Single Pitch Macro Thread Synchronized thread Preferred design for SLA surface High fixture strength Open Thread Prevents bone necrosis Reduces stress concentration Smaller platform compared to many designs allows platform switching. Corkscrew Thread Superior self-threading Ensures implant path Easy path change High primary stability Even stress distribution Decrease...

 Open the catalog to page 4
NTA Catalog-5

INTERNAL SUB-MERGED SYSTEM The SLA surface is produced by a large grit sand-blasting process with corundum particles that leads to a macro roughness on the titanium surface. This is followed by a strong acid-etching bath with a HCl at elevated temperature for several minutes. This produces the fine 2-4 μm micro pits superimposed on the rough-blasted surface. The surface is not micro porous and therefore provides no enclosed volumes to reduce vulnerability to bacteria. The chemical composition of the SLA structure was found to be titanium oxide (TiO2) using X-ray photoelectron spectroscopy. This...

 Open the catalog to page 5
NTA Catalog-6

Abutment Screw ( Set screw ) Abutment Screw ( Set screw ) Angled Milling Cemented Multi Angled Solid Abutment Cemented Abutment Solid Temporary Locater Soft Tissue Titanium Temporary Bone Forming NTA PACKING SYSTEM New Ampoule User’s Guide Transfer Type Impression Coping Remove the back of blister (sterility is not guaranteed if the seal is broken). Keep the small cover upward. Closing Screw Gold metalic color Ø 3.4 narrow Remove the cover by gently rotating and pulling. Insert the driver into the fixture and make sure that the driver is fully seated. Remove the cover screw from the small chamber...

 Open the catalog to page 6
NTA Catalog-7

NTA PROSTHETIC FLOW DIAGRAMS FOR OCTA SYSTEM NTA PROSTHETIC FLOW DIAGRAMS FOR MULTI ( ALL ON FOUR ) SYSTEM Octa Screw Multi Screw Multi Low Temporary Cylinder Octa Plastic Cylinder Multi Open Tray Imp. Coping Multi Cemented Cylinder Multi Low Transfer Imp. Coping Octa Protect Cap Multi Outer Driver Closing Screw Octa Impression Coping Octa Abutment Multi Low Plastic Cylinder Octa Lab Fixture Analog Octa Outer Driver Multi Abutment Multi Angled Abutment Healing Abutment 1.2 Screw Driver Closing Screw Healing Abutment

 Open the catalog to page 7
NTA Catalog-8

NTA PROSTHETIC FLOW DIAGRAMS FOR NTA SYSTEM OVERDENTURE RETAINED RESTORATION : N-LOC Internal Sub-merged System Metal Housing N-Loc Analog Ball Outer Driver Closing Screw N-Loc Impression Coping N-Loc Driver Healing Abutment

 Open the catalog to page 8
NTA Catalog-9

The implant body is taper thread and this provide spreading stress at the top of the implant. The depth of the threads at the apex part is the highest and its reduce by degrees inside the platform. The design of the implant enhance blood supply and minimalise the empty place in cortical bone to decrease bone formation period. Straight Body Implant and abutment excellent connection is waranted. 11° degree morse tapered connection is reducing stress on the fixture and decrease bone loss. Open Thread In the course of implant placement, open thread gives opportunity to place fixture deep without...

 Open the catalog to page 9
NTA Catalog-10

For Guided Bone Regeneration Immediate Placement Initial Fixation GBR Sinus graft Implant stability Vertical augmentation Immediate implant placement Fixture Soft Tissue Healing Abutment NTA Soft Tissue Healing Abutment Product Code HA STHA 553 M HA STHA 905 T HA STHA 907 T HA STHA 909 T Bone Forming Healing Abutment is used for protecting bone graft from tongue and saliva. BF Healing abutment covers bone graft with BF’s specific design. Bone Forming Healing Abutment D : Diameter T : Thickness C : Cuff Product Code HA BFHA 105 HA BFHA 205 HA BFHA 335 HA BFHA 106 HA BFHA 206 HA BF

 Open the catalog to page 10
NTA Catalog-11

NTA® HEALING ABUTMENT Internal Sub-merged System Esthetic Abutments conical connection; Prefabricated titanium abutments available in straight and angled ; and varying collar heights. ! Abutment Esthetic aHex Driver: 1.2 mm. aFastening Torque:5-8Ncm. Product Code

 Open the catalog to page 11
NTA Catalog-12

NTA® TEMPORARY ABUTMENT NTSA 45545 NTSA 45555 NTSA 45565 NTSA 45517 Product Code Height narrow Product Code NTA® SOLID NTA® TEMPORARY ABUTMENT - TITANIUM Product Code Product Code NTA® SOLID ABUTMENT a An abutment and a set screw, used a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional.

 Open the catalog to page 12
NTA Catalog-13

NTA® CEMENTED ABUTMENT Diameter Product Code Product Code NTCA 55635 H NTCA 55645 H NTCA 55665 H prosthesis and multiunit fixed partial restorations. a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional. 5 a Abutment for both single unit NTA® CEMENTED ABUTMENT NTCA 40527 H NTCA 40537 H NTCA 40547 H a Abutment for both single unit prosthesis and multiunit fixed partial restorations. a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional. NTCA 65727 H NTCA 65737 H NTCA 65747 H

 Open the catalog to page 13
NTA Catalog-14

NTA® CEMENTED ABUTMENT Diameter Product Code NTAA 55225 MH NTAA 55325 MH NTAA 55425 MH NTAA 50107 SH prosthesis and multiunit fixed partial restorations. a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional. 5 a Abutment for both single unit Product Code NTA® ANGLED ABUTMENT 4 1 a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular)

 Open the catalog to page 14

All NTA IMPLANT catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.