Normal Body Temperature: Normal body temperature varies by individual, time of day, and measurement location. Factors such as baths, exercise, and drinks can affect readings. Fever thresholds differ based on measurement location, including forehead, rectal, oral, and axillary readings.
Precautions for Use: Suitable for all users, including children and the elderly, but requires assistance for handicapped individuals. It is not a substitute for medical consultation and should be used indoors away from noise. Avoid using immediately after activities that can alter body temperature.
Product Description: The thermometer features an LCD screen, on/off button, sensor, and battery cover, designed for forehead temperature measurement.
Technical Specifications: Measures temperatures between 35.0°C and 43.0°C with varying accuracy. Operates best between 15°C and 35°C and uses a CR2032 battery.
℃/℉ Switch: To switch units, press the on/off button for 5 seconds when the device is off.
Measuring Guidelines: Ensure the forehead is clean and free from sweat. Avoid measuring over scars or open sores. Allow the device to reach room temperature if stored in cold conditions.
Operation: Ensure the forehead is clean, turn on the device, and wait for the "Ok" signal before measuring. Maintain good contact with the skin during measurement. A fever alarm sounds if the temperature exceeds 37.8°C.
Battery Replacement: Replace the battery when the symbol appears on the screen, ensuring correct polarity.
Troubleshooting: Error messages indicate issues like out-of-range temperatures or device malfunction. Follow specific solutions for each error.
Cleaning and Maintenance: Clean the sensor with alcohol and the body with a soft cloth. Verify accuracy every two years.
Disposal: Dispose of the product and battery separately, following local regulations.
Limited Warranty: The thermometer is warranted for two years against manufacturing defects, excluding battery and damage from misuse.
Applying Standards: Complies with various medical and safety standards, including MDD 93/42/EEC and EN 60601-1.
EMC Table: Designed to operate in specific electromagnetic environments, with guidelines for emissions and immunity.
Electromagnetic Environment and Compliance: Conduct an electromagnetic site survey to assess the environment due to fixed RF transmitters. If field strength exceeds RF compliance level, monitor the device for normal operation. Measures such as reorienting or relocating the device may be necessary. Field strengths over 150 kHz to 80 MHz should be less than 3 V/m.
Recommended Separation Distances: Designed for environments where radiated RF disturbances are controlled. Maintain a minimum distance between RF communications equipment and the device. A table provides recommended distances based on transmitter's output power and frequency. For example, a 0.01 W transmitter should maintain a distance of 0.12 m for frequencies between 150 kHz to 800 MHz, and 0.23 m for 800 MHz to 2.5 GHz. For a 100 W transmitter, the distances are 12 m and 23 m, respectively.
Additional Notes: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Guidelines may not apply in all situations due to factors like absorption and reflection from structures, objects, and people. An example indicates that a typical cell phone with a 2 W output requires a separation distance of 3.3 m at an immunity level of 3 V/m, as per IEC60601-1-2:2007 standards.
See more

Catalog excerpts

150206-321FB-IM-1

Digital Thermometer Instruction Manual Model:FT7122 (MT-B321FB) CONTENTS What is “normal” body temperature? Section 1: Precautions for use Section 2: Product Description Section 3: Technical Specifications Section 4: ℃/℉ Switch Section 5: Measuring Guidelines --------------------------------------- 3 Section 6: Operation ---------------------------------------- 4 Section 7: Battery Replacement ---------------------------------------- 5 Section 8: Troubleshooting --------------------------------------- 5 Section 9: Explanation of LOT number ---------------------------------------- 6 Section 10: Cleaning/Disinfection and Maintenance -------------------------- 6 Section 11: Disposal ---------------------------------------- 6 Section 12: Limited Warranty --------------------------------------- 7 Section 13: Applying Standards --------------------------------------- 7 Section 14: Symbol & Explanation ---------------------------------------- 7 Section 14: EMC Table ------------- -------------------------- 8 Read the instruction manual thoroughly and carefully before using the unit. What is “normal” body temperature? “Normal” body temperature varies from person to person, changes according to time of day and body location. Hot or cold baths, physical exercise, smoking and drinking, hot or cold drinks may change body temperature b one degree or more. The following table shows the temperature ranges: What is fever? Average normal temperature ranges Oral (mouth)* Axilla (armpit)* * Fever definitions according to Americ

 Open the catalog to page 1
150206-321FB-IM-2

The thermometer is designed to measure the temperature in the forehead, in approx.. between the end of eyebrow and the hairline. It is important to know that the thermal characteristics of each measurement body location – forehead, axillar, oral or rectal – are unique. The variance in temperature measurement in different body locations is due to the human body and not the thermometer. It is recommend to measure the body temperature when healthy to establish the specific normal temperature. PRECAUTIONS FOR USE The device can be used by all persons, including children, elderly person & Patient....

 Open the catalog to page 2
150206-321FB-IM-3

TECHNICAL SPECIFICATIONS Measurement time: Measurement location: The area between the end of eyebrow and the hairline Measurement range: Display unit: Storage (transport) condition: Operation condition: Battery life: 1,000 measurements approximately (under normal use) Approx. 25 grams including battery Last reading display when turn on Applied part: type BF (sensor) Degree of protection IP 22 from liquid and solid particle: The thermometer is not waterproof. Note 1: The thermometer is an adjusted mode clinical thermometer Note 2: This thermometer converts the forehead temperature to display its...

 Open the catalog to page 3
150206-321FB-IM-4

5. If the thermometer has been stored at a cold temperature, allow the unit to warm naturally to room temperature before using. 6. Performance of the device may be degraded if operated or stored outside stated temperature and humidity ranges. OPERATION Before measuring: 1. Sweat will affect the reading result on the forehead, so please make sure your forehead is clean before measurement. 2. Move the hair aside from the measurement location and apply the probe to the bare skin. Taking temperature 1. Press on/off button to turn on the unit. 2. The LCD window will display full segments for approx.....

 Open the catalog to page 4
150206-321FB-IM-5

Make sure that the probe completely touches the skin as below. For all types of thermometers, slight temperature variations can happen. Therefore, it is recommended to take several readings (removing the thermometer from the forehead between each measurement) and take the highest one into account. BATTERY REPLACEMENT When the battery symbol “ ” is displayed on the LCD screen, please replace the battery and follow the instructions below. Steps Gently press the top of the battery cover so as to release the battery cover. Slide back the battery cover. Take the battery out. When placing a new battery,...

 Open the catalog to page 5
150206-321FB-IM-6

Error signals Problems & Solutions Q: If the temperature is more than 43℃/109.4°F, the LCD displays “Hi”. A: Recheck the measured object before measuring. Q: If the temperature is below 35°C/95°F the LCD will keep displaying “Lo”. A: Recheck the measured object before measuring. Q: Informing battery replacement time. A: Replace the battery. Q: Operation temperature is out of range. A: Put the device at a place with normal room temperature (15°C ~35°C/59°F ~ 95°F) for, at least, 30 minutes before measuring. Q: If the thermometer has some problems and can’t measure temperatures, the LCD will display...

 Open the catalog to page 6
150206-321FB-IM-7

DISPOSAL 1. Please dispose of the product and the battery separately. 2. The product and the battery should not be disposed of with household waste. 3. Please follow local waste / battery disposal regulations. LIMITED WARRANTY This thermometer is guaranteed for 2 years from the date of purchase against Manufacturer's defect under normal use. If your unit does not function properly due to defective parts or assembly, we will repair it free of charge. All parts are covered by this warranty except the battery and damage to the unit due to improper handling. APPLYING STANDARDS MDD 93/42/EEC 2. EN...

 Open the catalog to page 7
150206-321FB-IM-8

Guidance and manufacturer’s declaration – electromagnetic emissions The FT7122 is intended for use in the electromagnetic environment specified below. The customer or the user of the FT7122 should assure that it is used in such an environment. Emissions test Electromagnetic environment – guidance The FT7122 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions The FT7122 is suitable for use in all establishments, including domestic CISPR 11 Harmonic emissions establishments...

 Open the catalog to page 8
150206-321FB-IM-9

IEC 61000-4-8 NOTE UT is the a.c. mains voltage prior to application of the test level. Guidance and manufacturer’s declaration – electromagnetic immunity The FT7122 is intended for use in the electromagnetic environment specified below. The customer or the user of the FT7122 should assure that it is used in such an environment. Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the FT7122 including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter....

 Open the catalog to page 9

All Nu-beca & maxcellent catalogs and technical brochures

  1. CN-7013

    18  Pages

  2. IT7278

    1  Page

  3. NCB360

    8  Pages

  4. POE101-B

    2  Pages

  5. PO8201

    28  Pages

  6. 2018DM_compress

    15  Pages

  7. Catalogue 2017

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.