Blood Pressure Monitor BA2318

Blood Pressure Monitor BA2318
1 / 29 PagesView full catalog

Blood Pressure Monitor BA2318

Product catalog summary
Safety Information
  • Warnings: Avoid using the device near strong electromagnetic fields or in environments with combustible gases. It is not suitable for use on infants or pregnant women. Ensure the cuff is properly fitted to avoid inaccurate results.
  • Contraindications: Do not apply the cuff over wounds or inflamed areas. Use under physician guidance if you have arrhythmia or other health conditions.
  • Care and Maintenance: Clean with a soft, dry cloth. Do not disassemble the device. Replace batteries as needed and store the device properly when not in use.
Product Features

The monitor measures human blood pressure and pulse rate, suitable for home use or by healthcare professionals. It includes features like memory storage for readings and a clear LCD display.

Pre-Measurement
  • Battery: Use four AAA batteries, ensuring correct polarity. Replace batteries when the low battery icon appears.
  • Setting: Set the date and time before use. The device can store two sets of memory data.
Taking a Measurement
  • Preparation: Avoid eating, drinking, or exercising 30 minutes prior. Rest for 5-10 minutes before measuring.
  • Cuff Fitting: Place the cuff 2-3 cm above the elbow, ensuring it is snug but not too tight.
  • Body Posture: Sit with your arm at heart level, relaxed and still during measurement.
  • Procedure: Turn on the device, wait for the beep, and remain still until the measurement is complete. The device will automatically shut off after 3 minutes.
Error Indication and Troubleshooting

If errors occur, refer to the troubleshooting section for guidance on resolving common issues.

Specifications

The device is an arm automatic blood pressure monitor with an LCD digital display, using the oscillometric method. The measurement range for pressure is 0mmHg to 280mmHg and for pulse is 40 to 180 beats per minute. It has a pressure accuracy of ±3mmHg and pulse accuracy of ±5%. Powered by 4 AAA alkaline batteries, it operates in temperatures between +5℃ and +40℃ and humidity levels of 15%-93%.

Procedures

To delete memory data, enter memory mode and follow specific instructions. Error codes are provided for troubleshooting, such as reconnecting the air tube or checking the cuff if the inflation rate is too low.

Error Indications

Error codes are listed with causes and corrective actions. For example, 'Er 2' indicates a weak signal or loose cuff, and the solution is to ensure the cuff is wrapped correctly. 'Lo' indicates low battery power, requiring a battery change.

Troubleshooting

Common issues include no display after battery installation, abnormal measured values, and low inflation rates. Solutions involve checking battery polarity, ensuring the cuff is correctly wrapped, and removing obstructive clothing.

Norms and Standards

The device complies with IEC60601-1-2:2007 standards for electromagnetic compatibility. Users are advised to maintain a minimum distance of 7 meters from devices generating strong electromagnetic fields.

Recommendations

Users are encouraged to monitor their blood pressure at home, especially for detecting morning hypertension, which is a risk factor for cardiovascular events. The document provides a blood pressure classification chart based on American Heart Association guidelines.

Disposal Instructions

The device should not be disposed of with domestic waste. Users must remove the battery before disposal and follow local regulations for electronic waste.

Electromagnetic Compatibility

Guidance is provided on maintaining electromagnetic immunity and emissions, recommending separation distances for RF communications equipment.

Warranty Rule
  • The product is guaranteed by nu-beca for one year from the purchase date.
  • The warranty excludes:
    • Transport risks.
    • Damages from non-compliant operating environments.
    • Defects from unauthorized repairs.
    • Damages from unauthorized disassembly or modification.
    • Discrepancies in the product guarantee card or altered cards.
  • Post-warranty paid services are available to ensure product accuracy.
Explanation of Symbols
  • Batch code symbol.
  • Date of manufacture symbol.
  • Electrical and electronic equipment symbol.
  • IP21: Protection against solid objects ≥ 12.5mm and vertical water drips.
  • Authorized representative in the European Community symbol.
  • Manufacturer symbol.
  • Follow operating instructions symbol.
  • Type BF applied part symbol.
  • CE 0123 symbol.
See more

Catalog excerpts

Blood Pressure Monitor BA2318-1

(Jibeca Arm Automatic Blood Pressure Monitor Instruction Manual Model: BA2318

 Open the catalog to page 1
Blood Pressure Monitor BA2318-3

1. Safety Information 1.1 Warning A • Self diagnosis and treatment which use measured results may be dangerous. Follow the instructions of your physicia or licensed healthcare provider. If cuff inflation doesn’t stop, remove the cuff or power off the unit , otherwise, it may result in a hazard condition. • Only take measurement with the manufacturer supplied cuff or else it will lead to inaccurate results. • Do not use the blood pressure monitor when you are close proximity to strong static electricity or electromagnetic fields and avoid using the mobile during measurement. Do not use in combination...

 Open the catalog to page 3
Blood Pressure Monitor BA2318-4

The battery has positive/negative polarity. If the battery does not connect well to the unit, do not forcibly connect it. Do not use Luer lock. If Luer lock connectors are used in the construction of tubing, there is a possibility that they might be inadvertently connected to intravascular fluid systems, allowing air to be pumped into a blood vessel. This product is suitable for use to self- monitoring of blood pressure in home or used by the licensed healthcare per sonnel in hospital. Blood pressure measurements determined with the device are equivalent to those obtained by a trained observer...

 Open the catalog to page 4
Blood Pressure Monitor BA2318-5

Rev:A1 Do not measurement too frequent, or else it may result in bruising where the cuff is applied. • Do not apply the cuff over a wound or inflamed area. The application of the cuff and its pressurization on the arm can cause temporary interference to blood flow, but it would not result in injury to the patient. Operation of the device does not result in prolonged impairment of the circulation of the blood of the patient. Direct plug is considered as disconnect device, please do not place the equipment in a difficultly operation position. When using the device, the patient is an intended operator. Do...

 Open the catalog to page 5
Blood Pressure Monitor BA2318-6

Avoid high temperature, moisture, dust and direct sunlight. Clean the body with soft dry cloth dipped in a concentration of 75% medical alcohol. Do not wet or cleaning the cuff with water. Clean the cuff with soft dry cloth after measurement. Do not use at extremely high temperature, high humidity, or high altitude. Use only within the required ambient conditions. Do not drop or expose the device to heavy shock. Do not use the unit near large equipment that uses a switching relay for power ON/OFF. Remove the batteries if the unit will not use for a long time. The blood pressure monitor has gone...

 Open the catalog to page 6
Blood Pressure Monitor BA2318-7

Body SET ON/OFF Memory Fig 1 Cuff (Type BF Applied Part) Model:BC1000 Applicable Arm Circumference: 220 mm to 360 mm Air Tube Connector Cuff

 Open the catalog to page 7
Blood Pressure Monitor BA2318-8

Fig 2 Symbol for TYPE BF APPLIED PART Display Blood Pressure Level Indicator Heart Mark Irregular Heat Rate Symbol Battery Symbol --Memory1 — Memory2 *&fSB8*BB Mean Symbol Date and Time Pulse Rate —Average Symbol

 Open the catalog to page 8
Blood Pressure Monitor BA2318-9

3. Pre Measurement 3.1 Battery 3.1.1 Installation and replacement 1)Remove battery cover 2)Load 4 standard AAA alkaline battery as indicated in figure below 4 x AAA Please use the same brand battery and aware of battery polarity during installation Fig 4 3)Install back the battery cover 4)Replace the battery if low battery icon is displayed If the low battery symbol is display, replace with new batteries, otherwise the unit will not function properly. Use 4 same brand 1.5 Volt AAA alkaline batteries. Do not mix the new and old batteries. Remove the battery if the unit is to remain unused for...

 Open the catalog to page 9
Blood Pressure Monitor BA2318-10

Rev:A1 The batteries enclosed in the package are used for demonstration purpose. It is possible that these batteries will therefore not last for 200 measurements. The battery life can be confirmed in the bottom left of the display. If the low battery symbol m - is display, remaining power is low, replace with new batteries. 3.2 Setting 3.2.1 Setting 1) With monitor power off 2) Hold the [Set] button for 3 seconds, Year digits blinking a) Change number i Press the [ M ] button to advance one number ii Hold down the [ M ] button the number will change rapidly b) Enter the two digit of the year...

 Open the catalog to page 10
Blood Pressure Monitor BA2318-11

b) Complete setting, press 【ON/OFF】 button to exit. 3.2.2 Memory Data Conversion The blood pressure monitor is capable to hold 2 sets of memory data. Prior using the blood pressure monitor, select the correct memory data. Memory data conversion: With monitor power off, hold the【ON/OFF】button until the selected Memory displayed. Press the【ON/OFF】button will automatically change the memory data conversion either from Memory 1 or Memory 2. The machine is complete setting, ready

 Open the catalog to page 11
Blood Pressure Monitor BA2318-12

4 Take a measurement 4.1 Important Noted Don't eat, drink alcohol, smoke, take a shower or exercise for at least 30 minutes before you take your blood pressure and don't use any medicines that can raise blood pressure. Try not to take your blood pressure if you are nervous or upset. If we are nervous, anxious, or agitated our blood pressure will rise. Rest for 5~10 minutes before taking a reading. Sit in a comfortable, relaxed position. Don't move around or talk while taking the blood pressure. Leave your legs in one position, breath freely and calmly. The blood pressure cuff should fit over...

 Open the catalog to page 12
Blood Pressure Monitor BA2318-13

Rev:A1 Air tube bladder locates in the center of the arm. Fig 9 4 ) Make sure cuff air tube outlet is facing your finger. Do not over tighten. Approximate one finger should be able to fit underneath the cuff after tightening. 5 ) Relax, place the elbow on the desk with palm facing up; the cuff should be level with your heart. If the cuff doesn’t fit your arm, the reading accuracy may be affected. Do not bend with the cuff or the air tube. To detach the cuff, unplug the air tube connector from the main unit Do not inflate prior fitting the cuff. Change the cuff, if it there is a leakage or if...

 Open the catalog to page 13
Blood Pressure Monitor BA2318-14

Rev:A1 Arm should be at the same level of your heart. 4.4 Take Measurement After installing the batteries and wearing the cuff, the unit is ready for measurement: 1 ) For the most accurate result please relax, do not smoke, take deep breath, speak loudly or move around during the measurement. 2 ) Turn on the 【ON/OFF】 button; display will lit-up for 1 second as shown on Fig 11. 3 ) Then the display on switch to Fig 12, a beep sound indicates the monitor has begun taking the measurement. 4 ) When the device detects a pulse, the heart symbol will flash as shown on Fig 13. The cuff inflates, and...

 Open the catalog to page 14

All Nu-beca & maxcellent catalogs and technical brochures

  1. CN-7013

    18  Pages

  2. IT7278

    1  Page

  3. 150206-321FB-IM

    11  Pages

  4. NCB360

    8  Pages

  5. POE101-B

    2  Pages

  6. PO8201

    28  Pages

  7. 2018DM_compress

    15  Pages

  8. Catalogue 2017

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.