NU-543
20Pages

{{requestButtons}}

Catalog excerpts

NU-543 - 1

CLASS II TYPE A2 BIOSAFETY CABINET The Safer Choice for Your Laboratory, Pharmacy, and You.

Open the catalog to page 1
NU-543 - 2

CLASS II TYPE A2 BIOSAFETY CABINET Designed By You. Designed for your Application. The LabGard® ES (Energy Saver) AIR model NU-543 is a Class II, filters are triple-checked, and biological tests are continually being Type A2 Biological Safety Cabinet offering Personnel, Product, and performed under dynamic conditions to ensure maximum safety. Environmental Protection through the use of quality design, an ultrahigh-efficiency motor, and longer lasting filters all at an affordable price. You deserve a quality and robust Biological Safety Cabinet every time you sit down to work. Every NuAire...

Open the catalog to page 2
NU-543 - 3

Maximum Access Flexibility Select from three window access opening options to meet the concerns of your facility and/or staff. 12" • 8” (203 mm) lower operating cost (NSF/ANSI49) (305 mm) • 10” (254 mm) lower costs and improved ergonomics (NSF/ANSI 49, EN12469) • 12” (305 mm) improved ergonomic reach by 40%* (NSF/ANSI 49) * As compared to an 8" (203 mm) access opening. Ultra High Efficiency Motor A single ultra-high efficiency ECM motor with a precision engineered fan blade minimizes energy usage while extending the life of filters. LabGard® offers the lowest total cost of ownership...

Open the catalog to page 3
NU-543 - 4

CLASS II TYPE A2 BIOSAFETY CABINET Ergonomic Design NuAire designs equipment for you that provides improved safety conditions; improved productivity; improved quality and reliability; and reduction of arm, shoulder, and neck strain which can contribute to common work place injuries. 6” (152 mm) • ADA Compliant • More Usable Work Area • Shorter Reach Into Work Zone • Recessed Air Foil • Recessed Work Zone • More Knee Room • Ability to Sit or Stand at a Range of Heights • 21” (533 mm) Frame-less Edge Window Sash Improves Vision/Sight Lines Into Work Zone • Staggered Service Valves A recessed...

Open the catalog to page 4
NU-543 - 5

Reduce Workplace Injuries Vie wi ng Lumbar Support for Lower Back [ Expanded Vision Zone ] [ Disposable Arm Rest Pads ] [ Recessed Airfoil Grill and elbow rest accessory ] Wrists Straight 90˚ Seat Back Angle Adjustable Seat Height [ Larger Work Area ] Footrest for Proper Post

Open the catalog to page 5
NU-543 - 6

CLASS II TYPE A2 BIOSAFETY CABINET Quality - Nothing is Built like a NuAire Monolithic Design. At core of any biosafety cabinet is its basic structure. NuAire has over 100,000 biosafety cabinets in the field; some of which have been running strong since the 1970’s. The NuAire design is a pressure tight, single piece of type 304 stainless steel. A stainless steel wrap [A] makes up the walls of the cabinet. Stainless steel sheets [B] are seam welded in place to make up the top and bottom of the cabinet. A smaller wrap [C] featuring coved interior corners is seam welded in place to make up the...

Open the catalog to page 6
NU-543 - 7

Pressure Tight Construction

Open the catalog to page 7
NU-543 - 8

NU-543 CLASS II TYPE A2 BIOSAFETY CABINET Ultra High Efficiency Motor. An ultra-high efficiency ECM motor combined with the properly sized fan blade lowers energy usage while extending the life of filters. LabGard® offers the lowest total cost of ownership compared to other models. Motor Comparison NuAire DC ECM NuAire AC PSC BSC with AC 3-Phase BSC with DC 8 hrs per day / 5 days per week = 2,000 hrs per year $0.09/kwh $54 $102 $75 $29 24 hrs per day / 7 days per week = 8,736 hrs per year 15 Year Life Cycle Costs Avg. Filter Changes12 1 Set 2 Sets 1 Set 3 Sets Estimated Cost of HEPA Filters...

Open the catalog to page 8
NU-543 - 9

Ultra High Efficiency Motor The LabGard® AIR comes standard with an Ultra High Efficiency Motor. Each motor has a precision engineered blower fan to maximize energy efficiency and filter life. The more powerful motor in model NU-543 equates to longer filter life lowering your total cost of ownership. Power Savings * Compares NuAire DC ECM motor technology and a BSC featuring DC motor technology. Information taken from page 7.

Open the catalog to page 9
NU-543 - 10

CLASS II TYPE A2 BIOSAFETY CABINET Your Safety is Our Number One Priority NuAire’s commitment to safety doesn’t stop at meeting industry standards. NuAire continually performs dynamic tests to push the limits of our product’s performance to ensure you and your laboratory personnel will remain safe. Automatic Airflow Compensation - the Ultra High Efficiency motor will automatically increase or decrease speed to maintain proper airflow settings based on readings from FlowGard Electronic Control System. True laminar (unidirectional) downward moving air flushes the work surface at 60 fpm (0.30...

Open the catalog to page 10
NU-543 - 11

Service Friendly Make it Easier on your Service Personnel We at NuAire® have designed each LabGard® Biosafety Cabinet to be service friendly. 100% of service functions can be performed at the front or top of the cabinet. Drop Down Control Panel A flip down control panel creates a workable tray for service technicians. Exhaust Choke Easy access to exhaust choke to certify airflows. Front Filter Access Access filters and the motor blower from the front of the cabinet with the removal of a safety panel. System Easily connect to a variety of decontamination systems that use Formaldehyde,...

Open the catalog to page 11
NU-543 - 12

CLASS II TYPE A2 BIOSAFETY CABINET Controlled Safety - Electronic Control System The LabGard® AIR offers the latest digital microprocessor design technology for improved cabinet performance and safety. The FlowGard™ control system integrates a dual thermistor airflow sensor (intelliflow™) to monitor the cabinet’s airflow performance. The FlowGard™ control system also integrates an ultra high efficiency motor / blower that provides automatic compensation for both filter loading and line voltage variances. The FlowGard™ also controls the motor / blower, visible light, UV light (optional),...

Open the catalog to page 12
NU-543 - 13

Personnel, Product, & Environmental Protection Perfectly Designed for You and Your Safety Air In-flow 70% Recirculated vs. 30% Exhausted Airflow Protects Personnel and Product LabGard® AIR utilizes a single motor blower system to maintain airflow performance. The single motor blower system is inherently balanced. As particulates load the HEPA filters between certifications, NuAire’s single motor/blower system maintains a consistent ratio of down flow to inflow, preventing uneven filter loading. This maintains a safer environment for you and your laboratory as well as maintains the proper...