1. Catalogs
  2. O-Two Medical Technologies
  3. O-Two Equinox® Relieve
video corpo

O-Two Equinox® Relieve

O-Two Equinox® Relieve

O-Two Equinox® Relieve

Product catalog summary
Overview: The O-Two Equinox® Relieve is a medical device designed to deliver a 50/50 mixture of nitrous oxide and oxygen for pain relief in conscious, spontaneously breathing patients. It is suitable for both pre-hospital and in-hospital settings, such as ambulances and emergency rooms.
Specifications: The system maintains a constant 50/50 gas mix and includes built-in alarms for low gas pressure. It automatically shuts off if pressure falls below 35 PSI. The device is virtually maintenance-free and features a single ON/OFF control, activating only with patient inspiratory effort. It has a minimum flow rate of 120 L/min and operates within a temperature range of 41°F to 104°F.
Safety Features: The device includes a secondary fail-safe circuit to prevent operation in case of internal malfunctions. It also features a scavenging hose to remove exhaled air, enhancing patient safety.
Ordering Information: The product comes with a two-year warranty against manufacturer defects. Various configurations and accessories are available, including single-use patient circuits and disposable mouthpieces.
Technical Details: The device has specific input connections for nitrous oxide and oxygen, with a patient connector size of 15/22 mm. It weighs 3.3 lbs and measures 8.9” x 6.6” x 3.9”.
See more

Catalog excerpts

O-Two Equinox® Relieve-1

O-Two Equinox® Relieve eveileR ®xoniuqE owT-O PRE-SET 50/50 MIX ANALGESIC GAS DELIVERY SYSTEM

 Open the catalog to page 1
O-Two Equinox® Relieve-2

The O-Two Equinox® Relieve is intended to provide a 50/50% mixture of nitrous oxide and oxygen, on demand, to a conscious, spontaneously breathing, patient for the relief of pain due to trauma or other conditions where inhalation analgesia is clinically specified. Designed for use in the pre-hospital (ambulance) and In-hospital use (ER, Labor and Delivery etc.), the system has no operator or patient adjustable controls eliminating the risk of delivering a hypoxic mixture. It only requires the attachement of pressure regulated medical gas oxygen and nitrous oxide cylinders and a patient circuit...

 Open the catalog to page 2

All O-Two Medical Technologies catalogs and technical brochures

  1. Statvac II

    2  Pages

  2. CAREvent PAR

    2  Pages

  3. CAREvent ALS+

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.