Product catalog summary
Introduction
Ocean SR spectrometers are engineered for high thermal stability and minimal unit variation, featuring interchangeable slits, indicator LEDs, and USB-C connectivity for easy setup. The package includes the spectrometer, a USB-C cable, and calibration data sheets.
Warnings & Cautions
Users must thoroughly read the manual before use. Important cautions include avoiding contaminants, using only specified components, and ensuring software installation before connecting the spectrometer to a PC. Repairs should be conducted only by authorized personnel.
Warranty and Compliance
Warranty details are available on the Ocean Optics website. The device complies with FCC Class A standards, RoHS materials standards, and is ISO 9001:2015 certified.
Installation and Setup
Software installation requires OceanView version 2.0.12 or above, compatible with Windows 8, 8.1, 10, and Mac OS X 10.5 or later. The spectrometer connects via USB, drawing power from the host computer. Proper driver installation is crucial for device recognition.
Hardware Features
The spectrometer includes status indicator LEDs and a 16-pin IO connector for interfacing with external equipment. It supports RS-232 communication as an alternative to USB.
Troubleshooting
If the spectrometer is connected before software installation, users may face driver issues. Solutions include removing the unknown device from Windows Device Manager and reinstalling drivers. FAQs address common issues like device recognition and driver installation problems.
Technical Specifications
Details on timing signals, trigger timing, mechanical dimensions, and calibration procedures are provided to ensure proper operation and maintenance of the spectrometer.
Power and Data Transmission Indicators
The spectrometer has a red LED indicating power status and a green LED that flashes when data is being transmitted.
Driver Installation
If the spectrometer is not recognized by the OceanView software, manual driver installation may be required. Instructions are available in the OceanView manual and on the Ocean Optics website.
Configuration Check
Configuration details can be checked on the spectrometer's label or through the OceanView software by accessing the Schematic window.
Repair and Servicing
For repairs, contact Ocean Optics to diagnose the issue and obtain an RMA number. The company covers shipping for warranty returns. Regular servicing, including wavelength recalibration, is recommended.
Technical Specifications
  • Optical and Spectroscopic: Integration times, dynamic range, signal-to-noise ratios, resolution, scan rates, and wavelength ranges are specified for SR2, SR4, and SR6 models.
  • Electrical: Power-up time, connector types, and power requirements are detailed.
  • Mechanical: Dimensions, weight, and environmental operating conditions are provided.
Timing Signals
The spectrometer provides Single and Continuous Strobe output signals for synchronizing external devices. The timing and configuration of these signals are user-defined.
Trigger Timing and Modes
The spectrometer supports Software Trigger, External Edge Trigger, and External Level Trigger modes. Each mode has specific timing characteristics and requirements, detailed in timing diagrams and tables.
Specifications and Timing Characteristics
Detailed timing characteristics for the Ocean SR Series spectrometers focus on external edge and level trigger modes. Key parameters include:
  • External Edge Trigger: Minimum pulse width of 10 ns, with delays and busy times specified for different models (SR4, SR6).
  • External Level Trigger: Integration time is determined by the pulse width, with specific delays and busy times for models SR2, SR4, and SR6.
Mechanical Dimensions
The spectrometer is designed for mounting using two #4-40 holes on the Samtec/Fiber input side.
Calibration
Each spectrometer is pre-calibrated with wavelength and linearity coefficients. Calibration can drift over time and environmental conditions. Ocean Optics provides resources for wavelength and irradiance calibrations, with tools available in OceanView software.
Contact Information
For further inquiries, Ocean Optics provides contact details for support in the US, Europe, and Asia.
Company Mission
Ocean Optics aims to provide technology and data for informed decision-making, enhancing human advancement in health, safety, and the environment.
See more

Catalog excerpts

OCEAN SR SERIES-1

OCEAN SR SERIES Multipurpose Spectrometers Installation and Operation Manual

 Open the catalog to page 1
OCEAN SR SERIES-2

Locations Americas Manufacturing & Logistics 3500 Quadrangle Blvd., Orlando, FL 32817, USA Sales: [email protected] Orders: [email protected] Support: [email protected] Duiven, NL Stuttgart (Ostfildern), DE Shanghai, PRC Ocean Applied 176 Anderson Ave, Ste. F304, Rochester, NY 14617 Ocean Optics China 666 Gubei Rd., Kirin Tower Suite 601B Changing District, Shanghai, PRC, 200336 International Light 10 Technology Drive, Peabody, MA 01960 Europe, Middle East & Africa Sales & Support Geograaf 24, 6921 EW Duiven, The Netherlands The Wheelhouse, 81 St. Clement’s Street Oxford OX4 1AW...

 Open the catalog to page 2
OCEAN SR SERIES-3

Table of Contents Before You Get Started Warnings & Cautions Ocean SR Spectrometers Connected to Computer Prior to Application Installation Frequently Asked Questions Product Description Technical Specifications Timing Signals Items Included with Shipment Trigger Timing Mechanical Dimensions Software Installation Configuring the Ocean SR Spectrometers Wavelength Calibration Hardware Setup Irradiance Calibrations Hardware Features Copyright © 2023 Ocean Optics, part of Ocean Insight All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,...

 Open the catalog to page 3
OCEAN SR SERIES-4

Before You Get Started Warnings & Cautions Caution: Read this manual thoroughly before using and operating this equipment. Caution: Do not let contaminants get into the bench. Keep the protective cap on the slit aperture when not connected to an accessory, probe or fiber. Caution: Only change the slit aperture in a clean environment where contaminants including dust cannot enter the bench during the procedure. Caution: Substitution of a component or accessory different from that supplied may result in measurement error, equipment damage, increased radio-frequency emissions or decreased immunity...

 Open the catalog to page 4
OCEAN SR SERIES-5

Warranty For the most current warranty information, please visit www.oceanoptics.com. This is an FCC Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency...

 Open the catalog to page 5
OCEAN SR SERIES-6

This device has been tested and complies with the following standards: Electromagnetic Compatibility Directive – 2014/30/EU RoHS Compliant This device complies with RoHS materials standards. Ocean Optics, the applied spectral knowledge company, has been certified for ISO 9001:2015 certification applicable to the design and manufacture of electro-optical equipment.

 Open the catalog to page 6
OCEAN SR SERIES-7

Introduction Product Description Ocean SR spectrometers are built using industry leading manufacturing techniques that help deliver high thermal stability and low unit-to-unit variation without compromising the flexibility and configurability that are the hallmark of the design. Features such as interchangeable slits, indicator LEDs and simple device connectors deliver more freedom and flexibility. Plug-and-play capability via the USB-C connection. User-interchangeable slit. LEDs show data transfer status. Items Included with Shipment • USB-C Cable Wavelength Calibration Data Sheet Linearity...

 Open the catalog to page 7
OCEAN SR SERIES-8

Installation and Setup NOTE Be sure to install the spectroscopy application BEFORE connecting the spectrometer to your PC. The software installs the drivers required for spectrometer installation. If you do not install the software first, the system will not properly recognize the spectrometer. If you have already installed the OCEAN SR to a computer running on a Windows platform prior to installing the operating software, consult the Troubleshooting section for information on correcting a corrupt OCEAN SR installation. Software Installation Use OceanView version 2.0.12 and above for Ocean SR...

 Open the catalog to page 8
OCEAN SR SERIES-9

Configuring SR Spectrometers Ocean SR spectrometers can be used with OceanView software when connected to the USB port. If you have followed the previous steps and started your spectroscopy application, the spectrometer is already acquiring data. Even with no light in the spectrometer, there should be a dynamic trace displayed in the bottom of the graph. If you allow light into the spectrometer, the graph trace should rise with increasing light intensity. This means the software and hardware are correctly installed. Hardware Setup Each Ocean SR spectrometer connects to a computer via the USB...

 Open the catalog to page 9
OCEAN SR SERIES-10

Hardware Features Ocean SRs Status Indicator LEDs Ocean SRs have two indicator lights that operate as shown: Unit is transmitting data NOTE LEDs can be turned off in OceanView or by using a software API command in OmniDriver or OceanDirect.

 Open the catalog to page 10
OCEAN SR SERIES-11

16 Pin IO Connector This port allows Ocean SR spectrometers to be connected to Ocean Optics light sources and other external equipment.

 Open the catalog to page 11
OCEAN SR SERIES-12

Spectrometer transmit to host Spectrometer receive from host External reset input External trigger input Single strobe output External power supply input Continuous strobe output Pins 4-12 on the auxiliary connector are 3.3V CMOS-compatible inputs or outputs, with +/- 1mA drive capability.

 Open the catalog to page 12
OCEAN SR SERIES-13

External Reset Input Pin Each Ocean SR spectrometer can reset itself via an external reset pin. Applying a logic low input to the RSTn pin places the Ocean SR into a hardware reset condition and will remain in reset until the input is brought high again. Note that this is a full hardware reset; all operating parameters are also reset to defaults that can be restored by re-initializing via software commands. This cable connects to the following external light sources: DH-3P DH-2000 (US) HPX series (US) HL-2000-FSHA HL-3P RS-232 Interface The spectrometer supports an optional RS-232 interface for...

 Open the catalog to page 13
OCEAN SR SERIES-14

Troubleshooting Sometimes things do not go according to plan. When issues arise, do not hesitate to contact us and our Tech Support team will leap into action. Some typical questions are answered here. For more information, consult the FAQs on the Ocean Optics website. Ocean SRs Connected to Computer Prior to Application Installation Remove the Unknown Device from Windows Device Manager 1. Open Windows Device Manager. Consult the Windows operating instructions for your computer for directions, if needed. 2. Locate the Other Devices option and expand the Other Devices selection by clicking on...

 Open the catalog to page 14

Archived catalogs

  1. USB2000+

    2  Pages

  2. USB4000

    2  Pages

  3. HR4000

    2  Pages

  4. HR2000+

    43  Pages

  5. Light Sources

    20  Pages

  6. Spectrometers

    58  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.