Lynx 12 Patient Monitor
1 /2Pages

Lynx 12 Patient Monitor

Lynx 12 Patient Monitor
1 /2Pages

Catalog excerpts

Lynx 12 Patient Monitor-1

Input dynamic range: ±(0.5mVp—5mVp) Differential input impedance: >I0MQ 0.5~40Hz (Monitoring) 1~20Hz (Operation) CMRR: >90dB (Diagnostic) >I05dB (Monitoring & Operation) Sensitivity selection: x|/4, x|/2, xI, *2, x4 an d Auto HR accuracy: ±1% or ±2bpm, whichever is greate Pacemaker pulse detection and rejection function Measuring accuracy: ±5% or ±2 rpm, whichever is greater Measuring accuracy: ±0.2 Cfrom 25—45 C Technique: Oscillometric method Typical measurement time : <30 seconds (adult cuff) NIBP measuring range : 40—200mmHg (Pediatric) NIBP measuring range: I0—I50mmHg (Pediatric) NIBP measuring range: 20—I65mmHg (Pediatric) 20—II0mmHg (Neonate) NIBP measuring accuracy: Mean difference: ±5mmHg NIBP measurement mode: Manual, Auto, STAT, Multi-cycle mode Auto measuring intervals: I-480min Technique: Dual-wavelength optical method Measuring accuracy: Arms is not greater than 2% for SpO2 range 70—I00%. PR measuring range: 30—250bpm PR measuring accuracy: ±2bpm or ±2%, whichever is greater Technique: Infrared optical method Sampling mode: Sidestream or Mainstream 4I~70mmHg ±5% of reading 7I~I00mmHg ±8% of reading I0I~I50mmHg ±I0% of reading Flow rate: 50ml/min ±I0 ml/min (Sidestream) Cerebral State Monitoring (CSM) EEG sensitivity: ±400pV CSI and update: 0-I00. filter: 6-42Hz, I sec. update filter: 75-85 Hz, I sec. update. BS%: 0-I00. filter: 2-42 Hz, I sec. update Technique: Strain gauge transducer Measuring accuracy: ±2% or ±4mmHg, whichever is greater ICP, AUXPI, AUXP2 Calibration: zero calibrating Cardiac Output (C.O.) Blood temperature measuring: range: 23-43 C, accuracy: ±0.5 C Injecta temperature measuring: range: 0-20 C, accuracy: ±0.5 C Measuring range: 0.2—20 L/min Measuring accuracy: ±0.2 L/min or ±I0%, whichever is greater Other Specifications Power supply:_AC I00V-240V, 50/60Hz, 60VA Built-in lithium battery: II.IV/4400mAh Display: I2.I inch TFT display Alarming method: 3 levels audible-visible alarm Networking: Ethernet Standard configuration ECG, Respiration, SpO2, PR, NIBP, Temperature Options 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, I2-lead ECG Cardiac Output, Cerebral State Monitoring, CMS, Touch Screen Patient Monitor OES MEDICAL LTD OES Medical Limited ABC House, Cotswold Dene, Standlake Witney, Oxfordshire, OX29 7QG Tel: +44 (0)1865 301711 Fax: +44 (0)1865 301573 e-mail: [email protected] www.oes-medical.co.uk

 Open the catalog to page 1
Lynx 12 Patient Monitor-2

12.1” display with LED backlight 9-waveform on screen 360-degree visible indicator with 3-level alarm Patient Monitor Accessory box for standard configuration Integral 3-channel thermal recorder Li-ion battery up to 4 hours continuous monitoring Parameter case for optional parameters Comprehensive calculations for clinical application 12.1” high resolution display Touch screen optional 9 traces on-screen waveforms and maximal up to 13 User customized NIBP measuring cycles up to 5-phase Data export and software upgrade Versatile clinical calculations for application convenience HL7 protocol, Bed...

 Open the catalog to page 2

All OES Medical catalogs and technical brochures

  1. Astra

    4  Pages

  2. CYGNUS

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.