Electrical Stimulator IVES Model GD-611

Open the catalog to page 1
2017 IVES - 2

Effective rehabilitation with IVES IVES is an Integrated Volitional control Electrical Stimulator that can be used for upper- or lower-limb rehabilitation of patients with paralysis caused by cerebrovascular diseases or locomotive disabilities.

Open the catalog to page 2
2017 IVES - 3

All functions from setup to treatment are integrated into one compact body A variety of treatment modes, to fit a wide range of pathologies "Power Assist mode" as well as five other treatment modes are available. A single unit can be used for various cases of patients' needs. Up to 45 treatment patterns can be stored Up to 45 treatmet patterns can be assigned a name, stored and easily recalled for later use. IVES+ administrative functions When IVES is connected, its treatment modes are enabled and a patient's treatment history including total treatment time, the number of times stimulation...

Open the catalog to page 3
2017 IVES - 4

Outputs electrical stimulation in proportion to EMG signal Reads the EMG signal triggered by the motor command Flexing the wrist with limited voluntary motion only Flexing the wrist with greater voluntary motion in Power Assist Mode Strong electric stimulation is given Electrical Stimulation EMG signal Electrical Stimulation EMG signal

Open the catalog to page 4
2017 IVES - 5

Equipped with six treatment modes to accommodate a variety of symptoms and conditions, from the hospital to the patient's home Mild Medium Strong Q Power Assist Mode Q External Assist Mode -!-!-1 Q Trigger Mode Q External Trigger Mode -1-1-1 Q Normal Mode Q Sensor Trigger Mode •Image showing the scope of application for each treatment mode Q External Assist Mode *Available only for GD-611 •Requires bipolar electrode cord (optional accessory) Electrical stimulation is emitted in proportion to the EMG signal in a body part other than the one being treated. By stimulating the paralyzed...

Open the catalog to page 5
2017 IVES - 6

Our original electrode design enables precise treatment IVES' unique "separation of myoelectric detection and electrical Stimulation output" technology* integrates the myoelectric detection electrode and the electrical Stimulation electrode into one. Also, the fixed distance between IVES' bipolar gel electrodes makes it easy to precisely duplicate the desired electrode positioning over multiple treatments. * Development of an EMG recording device from stimulation electrodes for functional electrical stimulation. Yoshihiro Muraoka, Front Med Biol Eng.2002;11 (4)323-33. 2-pole Electrode Cord...

Open the catalog to page 6
2017 IVES - 8

IVES+GD-611 Rated power supply Power input External dimensions Treatment modes Treatment time Output waveform Output frequency Maximum output voltage Maximum output current Safety function Rated power supply 6V DC (4 AA alkaline batteries or AA Ni-MH rechargeable batteries) Normal Mode / Trigger Mode / Power Assist Mode Sensor Trigger Mode (when Gait Sensor is being used) External Trigger Mode (when using 2-pole Electrode Cord) External Power Assist Mode (when using 2-pole Electrode Cord) 5, 10, 15, 20, 25, 30 min. and continuous (When Sensor Trigger Mode has been selected, continuous only)...

Open the catalog to page 8

All OG Wellness Technologies catalogs and technical brochures

  1. TUTTI

    4 Pages

  2. Prefit

    4 Pages

  3. ORTHOTRAC

    4 Pages

  4. OG Packs

    2 Pages

  5. QUATTROMANO

    4 Pages

  6. PHYSISYSTEM

    8 Pages

  7. AUDIOTRON

    4 Pages

  8. HS-30

    3 Pages

  9. ORTHO TRAC

    4 Pages

  10. PHYSIOUS

    3 Pages

  11. PAS

    3 Pages

Archived catalogs

  1. MICRO THERMY

    4 Pages

  2. PHYSISONIC

    3 Pages

  3. IVES

    5 Pages