Medical Gas Color LCD Touch Screen Area Alarm

Medical Gas Color LCD Touch Screen Area Alarm

Medical Gas Color LCD Touch Screen Area Alarm

Product catalog summary
Overview: The Ohio Medical Color LCD Touch Screen Area Alarm is designed for monitoring medical gas conditions with ease and clarity. It features a user-friendly interface with a color LCD touch screen, allowing for quick setup and reliable operation.
Features and Benefits:
  • Color LCD Touch Screen: Provides clear identification of gases and alarm conditions with a 5.7" display. The screen brightness is adjustable for visibility in various lighting conditions.
  • Certification and Compliance: UL and CSA certified, meeting NFPA 99 Health Care Facilities Code.
  • Connectivity: Connects to Building Management Systems (BMS) via dry contacts to identify high/low alarm conditions.
  • Customizable Options: User-defined, password-protected settings available in English or Spanish, with NFPA or ISO color options and various pressure units.
  • Alarm Indicators: Audible and LED visual indicators clearly identify alarm conditions.
  • Zone Naming: Allows up to 20 characters for practical naming of sensor zones.
  • Durability: Constructed to protect electronics from environmental conditions and electrical interference.
Installation and Maintenance:
  • Easy Setup: No push buttons or hidden switches; setup is done via the touch screen panel.
  • Security: Individual setup and maintenance screen passwords enhance security.
  • Programmable Setup: Supports up to 8 gases for a single zone and 4 gases per zone for two-zone alarms.
  • Adjustable Settings: Factory set to meet NFPA requirements, with customizable gas pressure and vacuum settings.
  • Auto Detection: Auto-detects sensor locations and allows manual selection if needed.
  • Self-Diagnostics: Provides error messages for sensor mismatch or disconnect conditions.
Technical Specifications:
  • Alarm Box and Panel: Listed to UL1069 and CSA standards, compliant with NFPA 99, and manufactured in an ISO-certified environment.
  • Display: 5.7" pressure-activated screen with adjustable brightness, suitable for use with medical gloves.
  • Security Codes: Supplied for setup and maintenance screens.
  • Multiple Zone Setup: Supports up to 8 gases for single zone and 4 gases per zone for two-zone applications.
  • Automatic Detection: Auto-verification of sensor locations with user-defined setup.
  • Digital Sensors: Communicate continuous digital readouts for pressure and vacuum, with remote mounting capabilities.
  • Construction: Made from 18-gauge steel with protective materials for electronics.
Ordering Information: The document provides part numbers for configuring local and remote area alarms with various gas types.
See more

Catalog excerpts

Medical Gas Color LCD Touch Screen Area Alarm-1

Ohio Medical always there for life Medical Gas Color LCD Touch Screen Area Alarm

 Open the catalog to page 1
Medical Gas Color LCD Touch Screen Area Alarm-2

Ohio Medical’s Color LCD Touch Screen Area Alarm offers quick and easy set-up as well as crystal clear monitoring of medical gas conditions. A user defined password leads the alarm operator through all necessary set-up procedures. The alarm seamlessly auto detects sensor locations and depicts their zone locations via the color LCD touch screen to ensure sensor locations are properly identified during installation and maintenance. Sensor locations and gas settings may be adjusted or reconfigured - depending on the application. Features and Benefits For the User Color LCD Touch Screen ■ Crystal...

 Open the catalog to page 2
Medical Gas Color LCD Touch Screen Area Alarm-3

Specifications Alarm Box and Panel ■ Listed to UL1069 (Hospital Signaling and Nurse Call Equipment) and CSA C22.2 No. 2015-12 (Signal Equipment). ■ Product complies with NFPA 99 and is manufactured in an ISO 9001 and ISO 13485 environment. ■ Alarm shall incorporate a Liquid Crystal Display (LCD) to continuously indicate pressure or vacuum levels. ■ Alarm shall be able to restart after a power loss of 10 seconds. Field Programmable Set-up ■ Alarm shall be adjustable to display NFPA or ISO colors as well as gas settings including: PSI / KpA or inHg / mmHg. ■ Alarm shall display English or Spanish...

 Open the catalog to page 3
Medical Gas Color LCD Touch Screen Area Alarm-4

Ordering Information (Part Numbers) To configure an area alarm, select the alarm type, then select gas type(s). EXAMPLE: 263853,O, A, V = Remote Area Alarm with 3 gases (Oxygen, Air, Vacuum) 263853 , O,A,V Local Area Alarm 1 Gas 263861 2 Gases 263862 3 Gases 263863 4 Gases 263864 5 Gases 263865 6 Gases 263866 7 Gases 263867 8 Gases 263868 Remote Area Alarm 1 Gas 263851 2 Gases 263852 3 Gases 263853 4 Gases 263854 5 Gases 263855 6 Gases 263856 7 Gases 263857 8 Gases 263858 Gas Type (enter Gas Type after part number) Example: 263853,O, A, V = Remote Area Alarm with 3 gases (Oxygen, Air, and Vacuum) Example: 263868,O,...

 Open the catalog to page 4

Archived catalogs

  1. Care-E-Vac 3

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.